A Reliable and Rapid Method for Simultaneous Determination of Furfural and Hydroxymethyl Furfural in Oil Refinery Wastewaters by Ant Colony/Partial Least-Squares Analysis

2020 ◽  
Vol 75 (11) ◽  
pp. 1486-1496
Author(s):  
Ali Akbar Miran Beigi
2003 ◽  
Vol 493 (1) ◽  
pp. 83-94 ◽  
Author(s):  
Leticia López-Martı́nez ◽  
Pedro Luis López-de-Alba ◽  
Rosalinda Garcı́a-Campos ◽  
Luis M De León-Rodrı́guez

RSC Advances ◽  
2015 ◽  
Vol 5 (86) ◽  
pp. 70017-70024 ◽  
Author(s):  
Hadi Parastar ◽  
Hamidreza Shaye

The potentials of PLSR and MCR-ALS are evaluated for the simultaneous determination of diclofenac, naproxen, mefenamic acid and carbamazepine as target analytes and gemfibrozil as interference in synthetic and real environmental samples.


2016 ◽  
Vol 99 (3) ◽  
pp. 649-663 ◽  
Author(s):  
Mital N Patel ◽  
Charmy S Kothari

Abstract Multivariate UV-spectrophotometric methods and Quality by Design (QbD) HPLC are described for concurrent estimation of avanafil (AV) and dapoxetine (DP) in the binary mixture and in the dosage form. Chemometric methods have been developed, including classical least-squares, principal component regression, partial least-squares, and multiway partial least-squares. Analytical figures of merit, such as sensitivity, selectivity, analytical sensitivity, LOD, and LOQ were determined. QbD consists of three steps, starting with the screening approach to determine the critical process parameter and response variables. This is followed by understanding of factors and levels, and lastly the application of a Box-Behnken design containing four critical factors that affect the method. From an Ishikawa diagram and a risk assessment tool, four main factors were selected for optimization. Design optimization, statistical calculation, and final-condition optimization of all the reactions were Carried out. Twenty-five experiments were done, and a quadratic model was used for all response variables. Desirability plot, surface plot, design space, and three-dimensional plots were calculated. In the optimized condition, HPLC separation was achieved on Phenomenex Gemini C18 column (250 × 4.6 mm, 5 μm) using acetonitrile–buffer (ammonium acetate buffer at pH 3.7 with acetic acid) as a mobile phase at flow rate of 0.7 mL/min. Quantification was done at 239 nm, and temperature was set at 20°C. The developed methods were validated and successfully applied for simultaneous determination of AV and DP in the dosage form.


Sign in / Sign up

Export Citation Format

Share Document