Interobserver agreement and image quality of functional cardiac ultrasound measures used in a randomised trial of delayed cord clamping in preterm infants

2017 ◽  
Vol 103 (3) ◽  
pp. F257-F263 ◽  
Author(s):  
Himanshu Popat ◽  
Kristy P Robledo ◽  
Lucille Sebastian ◽  
Nicholas Evans ◽  
Andrew Gill ◽  
...  

ObjectiveFunctional cardiac ultrasound measures are used clinically and in trials for assessing the haemodynamic status of newborn infants. Superior vena cava (SVC) flow and right ventricular output (RVO) are established measures of systemic blood flow on the first postnatal day. The objective was to assess image quality and interobserver agreement of these measures in preterm infants enrolled in a randomised trial of immediate versus delayed cord clamping.Design and settingImage quality and interobserver agreement for SVC flow, RVO and ductus arteriosus (DA) size were assessed on measurements taken at 3–6, 6–12 and 20–28 hours for the first 10 infants enrolled at each of four sites (total 40). Bland-Altman plots were constructed; mean difference (bias) and limits of agreement (LOA) were calculated. Potential sources of variation were explored.ResultsQuality was judged satisfactory for >97% of images. The mean difference and LOA between the observers were 5.4 mL/kg/min and −49.0 to 59.8 mL/kg/min for SVC flow, −26.6 mL/kg/min and −131.4 to 78.2 mL/kg/min for RVO, and 0 mm and −0.8 to 0.8 mm for DA diameter, respectively. The principal source of measurement error for SVC flow was diameter, and for RVO, diameter and velocity time integral. The difference between observers for both SVC and RVO was significantly associated with site.ConclusionInterobserver variability for SVC flow is consistent with that previously reported, but higher for RVO. The findings should be incorporated into clinical practice, training, accreditation and trial design.

Children ◽  
2021 ◽  
Vol 8 (5) ◽  
pp. 336
Author(s):  
Michael P. Meyer ◽  
Elizabeth Nevill

Major physiologic changes occur during the transition after birth. For preterm infants, current understanding favours allowing the initial changes to occur prior to cord clamping. Amongst other improved outcomes, systematic reviews have indicated a significant reduction in neonatal blood transfusions following delayed cord clamping. This may be due to a placental transfusion, facilitated by the onset of respiration. If breathing is compromised, placental transfusion may be reduced, resulting in a greater red cell transfusion rate. We designed a randomised trial to investigate whether assisting respiration in this high-risk group of babies would decrease blood transfusion and improve outcomes. The Assisted Breathing before Cord Clamping (ABC) study is a single-centre randomised controlled trial. Preterm infants < 31 weeks that have not established regular breathing before 15 s are randomised to a standard or intervention group. The intervention is intermittent positive pressure ventilation via T piece for 30 s, whilst standard management consists of 30 s of positioning and gentle stimulation. The cord is clamped at 50 s in both groups. The primary outcome is the proportion of infants in each group receiving blood transfusion during the neonatal admission. Secondary outcomes include requirement for resuscitation, the assessment of circulatory status and neonatal outcomes.


Sign in / Sign up

Export Citation Format

Share Document