interobserver agreement
Recently Published Documents


TOTAL DOCUMENTS

1350
(FIVE YEARS 366)

H-INDEX

69
(FIVE YEARS 8)

2022 ◽  
Vol 23 (1) ◽  
Author(s):  
Hasan Banitalebi ◽  
Ansgar Espeland ◽  
Masoud Anvar ◽  
Erland Hermansen ◽  
Christian Hellum ◽  
...  

Abstract Background Magnetic Resonance Imaging (MRI) is an important tool in preoperative evaluation of patients with lumbar spinal stenosis (LSS). Reported reliability of various MRI findings in LSS varies from fair to excellent. There are inconsistencies in the evaluated parameters and the methodology of the studies. The purpose of this study was to evaluate the reliability of the preoperative MRI findings in patients with LSS between musculoskeletal radiologists and orthopaedic spine surgeons, using established evaluation methods and imaging data from a prospective trial. Methods Consecutive lumbar MRI examinations of candidates for surgical treatment of LSS from the Norwegian Spinal Stenosis and Degenerative Spondylolisthesis (NORDSTEN) study were independently evaluated by two musculoskeletal radiologists and two orthopaedic spine surgeons. The observers had a range of experience between six and 13 years and rated five categorical parameters (foraminal and central canal stenosis, facet joint osteoarthritis, redundant nerve roots and intraspinal synovial cysts) and one continuous parameter (dural sac cross-sectional area). All parameters were re-rated after 6 weeks by all the observers. Inter- and intraobserver agreement was assessed by Gwet’s agreement coefficient (AC1) for categorical parameters and Intraclass Correlation Coefficient (ICC) for the dural sac cross-sectional area. Results MRI examinations of 102 patients (mean age 66 ± 8 years, 53 men) were evaluated. The overall interobserver agreement was substantial or almost perfect for all categorical parameters (AC1 range 0.67 to 0.98), except for facet joint osteoarthritis, where the agreement was moderate (AC1 0.39). For the dural sac cross-sectional area, the overall interobserver agreement was good or excellent (ICC range 0.86 to 0.96). The intraobserver agreement was substantial or almost perfect/ excellent for all parameters (AC1 range 0.63 to 1.0 and ICC range 0.93 to 1.0). Conclusions There is high inter- and intraobserver agreement between radiologists and spine surgeons for preoperative MRI findings of LSS. However, the interobserver agreement is not optimal for evaluation of facet joint osteoarthritis. Trial registration www.ClinicalTrials.gov identifier: NCT02007083, registered December 2013.


2022 ◽  
pp. 084653712110651
Author(s):  
Yet Yen Yan ◽  
Hugue A. Ouellette ◽  
Mayuran Saththianathan ◽  
Peter L. Munk ◽  
Paul I. Mallinson ◽  
...  

Purpose: To determine the sensitivity and specificity of dual-energy CT (DECT) virtual noncalcium images (VNCa) with bone and soft tissue reconstructions in the diagnosis of osteomyelitis. Materials & Methods: Between December 1, 2014 to December 1, 2020, 91 patients who had 99 DECT performed for a clinical indication of osteomyelitis with corresponding MRI, triphasic bone scan and/or white blood cell scintigraphy with CT/SPECT performed either 2 weeks before or 1 month after the DECT were retrospectively identified. The presence or absence of osteomyelitis was established using a second imaging test, bone biopsy or surgery. Two radiologists interpreted VNCa images alone and with bone and soft tissue reconstructions for osteomyelitis. Fleiss k statistics was used to assess inter-level agreement. Results: Osteomyelitis was present in 26 cases (26.2%), of which 4 cases (4%) had co-existing septic arthritis. DECT was performed at the following sites: ankle/foot (n = 59), calf (n = 12), knee (n = 3), thigh (n = 7), hip (n = 9), pelvis (n = 6), wrist/hand (n = 1), and shoulder (n = 2). Sensitivity with VNCa images alone was 53.8% and 73.1% and specificity was 84.9% and 71.2%. Sensitivity with VNCa images and bone and soft tissue reconstructions was 80.8% and 80.8% and specificity was 80.8% and 72.6%. Interobserver agreement was 76.7% (76 of 99 cases), for VNCa images alone (k = .487), and 66.7% (66 of 99 patients) for bone and soft tissue reconstructions with VNCa images together (k = .390). Conclusion: When VNCa images were combined with bone and soft tissue reconstructions, there is improved sensitivity in the diagnosis of osteomyelitis.


2022 ◽  
Author(s):  
Solveig Kärk Abildtrup Larsen ◽  
Vibeke Løgager ◽  
Catharina Bylov ◽  
Hanne Nellemann ◽  
Mads Agerbæk ◽  
...  

Abstract Purpose Concerns of imaging-related radiation in young patients with high survival rates have increased the use of magnetic resonance imaging (MRI) in testicular cancer (TC) stage I. However, computed tomography (CT) is still preferred for metastatic TC. The purpose of this study was to compare whole-body MRI incl. diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) with contrast-enhanced, thoracoabdominal CT in metastatic TC.Methods A prospective, non-inferiority study of 84 consecutive patients (median age 33 years) with newly diagnosed metastatic TC (February 2018 - January 2021). Exclusion criteria were age <18 years, claustrophobia and MRI contraindications. Patients had both MRI and CT before and after treatment. Anonymised images were reviewed by experienced radiologists.Lesion malignancy was evaluated on a Likert scale (1 benign – 4 malignant). Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated on patient and lesion level. For non-inferiority testing, the difference in sensitivity between CT and MRI was calculated. The level of significance was set at 5%. ROC curves and interobserver agreement were calculated.Results On patient level, MRI had 98% sensitivity and 75% specificity compared to CT. On lesion level within each modality, MRI had 99% sensitivity and 78% specificity, whereas CT had 98% sensitivity and 88% specificity. MRI sensitivity was non-inferior to CT (difference 0.57% (95% CI -1.4-2.5%)). The interobserver agreement was substantial between CT and MRI. Conclusion MRI with DWIBS was non-inferior to contrast-enhanced CT in detecting metastatic TC disease. Trial registration www.clinicaltrials.gov NCT03436901, finished July 1st 2021.


Author(s):  
Guillaume Vautravers ◽  
Fabrice Audigié ◽  
Jean-Marie Denoix

Abstract OBJECTIVE To describe scintigraphic and transrectal ultrasonographic anatomic variants of the lumbosacral (LS) articulation in horses and to determine the agreement between results obtained with each imaging modality. ANIMALS 243 horses (81 Selle Français Warmbloods, 81 French Standardbred Trotters, and 81 Thoroughbreds). PROCEDURES A retrospective search of clinical records was conducted to identify horses that had undergone nuclear scintigraphy and transrectal ultrasonography of the LS region of the vertebral column between January 2016 and December 2019. Scintigraphic images were evaluated by 2 observers blinded to the other’s results for classification of LS articulation anatomic variants (scintigraphic type); intra- and interobserver agreement were determined. Ultrasonographic images were evaluated for classification of LS intervertebral symphysis anatomic variant (ultrasonographic grade) by 1 observer blinded to horses’ identities and scintigraphic findings; agreement analysis was performed between scintigraphic type and ultrasonographic grade. Descriptive and statistical analyses were performed to describe distribution of anatomic variants. RESULTS The scintigraphic classification system (scintigraphic type) had excellent intra- and interobserver agreement. Agreement between results for scintigraphic type and ultrasonographic grade was moderate (κ = 0.61; 95% CI, 0.52 to 0.70). Anatomic variants of the LS articulation were observed in all groups. The distribution of variants differed significantly among breeds but not sexes. CLINICAL RELEVANCE Anatomic variations of the LS articulation in horses must be known to avoid misinterpreting them as clinically meaningful findings. Further research is needed to determine potential relationships between these anatomic variants and LS lesions, their clinical manifestations, and their influence on athletic performance.


Author(s):  
Puja Shahrouki ◽  
Sarah N. Khan ◽  
Takegawa Yoshida ◽  
Paul J. Iskander ◽  
Shahnaz Ghahremani ◽  
...  

Abstract Background Gadofosveset is a gadolinium-based blood pool contrast agent that was approved by the United States Food and Drug Administration in 2008. Its unanticipated withdrawal from production in 2016 created a void in the blood pool agent inventory and highlighted the need for an alternative agent with comparable imaging properties. Objective The purpose of our study is to compare the diagnostic image quality, vascular contrast-to-noise ratio (CNR) and temporal signal characteristics of gadofosveset trisodium and ferumoxytol at similar molar doses for high-resolution, three-dimensional (3-D) magnetic resonance (MR) venography in children. Materials and methods The medical records and imaging data sets of patients who underwent high-resolution 3-D gadofosveset-enhanced MR venography (GE-MRV) or ferumoxytol-enhanced MR venography (FE-MRV) were retrospectively reviewed. Two groups of 20 pediatric patients (age- and weight-matched with one patient common to both groups; age range: 2 days–15 years) who underwent high-resolution 3-D GE-MRV or FE-MRV at similar molar doses were identified and analyzed. Qualitative analysis of image quality and vessel definition was performed by two blinded pediatric radiologists. Interobserver agreement was assessed with the AC1 (first-order agreement coefficient) statistic. Signal-to-noise ratio (SNR) and CNR of the inferior vena cava and aorta were measured in the steady-state venous phase. Medical records were retrospectively reviewed for any adverse reactions associated with either contrast agent. Results Measured SNR and CNR of the inferior vena cava were higher for FE-MRV than GE-MRV (P = 0.034 and P < 0.001, respectively). The overall image quality score and individual vessel scores of FE-MRV were equal to or greater than GE-MRV (P = 0.084), with good interobserver agreement (AC1 = 0.657). The venous signal on FE-MRV was stable over the longest interval measured (1 h, 13 min and 46 s), whereas venous signal on GE-MRV showed more variability and earlier loss of signal. No adverse reactions were noted in any patient with either contrast agent. Conclusion Ferumoxytol produces more uniform and stable enhancement throughout the entire venous circulation in children than gadofosveset, offering a wider time window for optimal image acquisition. FE-MRV offers a near-ideal approach to high-resolution venography in children at all levels of anatomical complexity.


Sign in / Sign up

Export Citation Format

Share Document