scholarly journals A low-cost adaptive data separation method for the flash translation layer of solid state drives

Author(s):  
Wei Xie ◽  
Yong Chen ◽  
Philip C. Roth
Author(s):  
Yingbiao Yao ◽  
Jinlong Fan ◽  
Jie Zhou ◽  
Xiaochong Kong ◽  
Nenghua Gu

IEEE Access ◽  
2019 ◽  
Vol 7 ◽  
pp. 95233-95239
Author(s):  
Jun Li ◽  
Xiaofei Xu ◽  
Bowen Huang ◽  
Jianwei Liao ◽  
Xiaoning Peng

Solid state drives (SSDs)have emerged as faster and more reliable data storages over the last few years. Their intrinsic characteristics prove them to be more efficient as compared to other traditional storage media such as the Hard Disk Drives (HDDs). Issues such as write amplification, however, degrade the performance and lifespan of an SSD. This issue is in turn handled by the Garbage Collection (GC) algorithms that are put in place to supply free blocks for serving the writes being made to the flash-based SSDs and thus reduce the need of extra unnecessary writes. The LRU/FIFO, Greedy, Windowed Greedy and D choices algorithms have been described to lower write amplification for incoming writes which are different in nature. The performance of the GC algorithms varies based on factors such as pre-defined hot/cold data separation, hotness of data, uniform/non-uniform nature of incoming writes, the GC window size and the number of pages in each block of the flash memory package. Finally, it can be seen that the number of write frontiers so used, can dictate the separation of hot/cold data and increase the performance of a GC algorithm.


Polymers ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 1192
Author(s):  
Hisham S. M. Abd-Rabboh ◽  
Abd El-Galil E. Amr ◽  
Abdulrahman A. Almehizia ◽  
Ayman H. Kamel

In recent times, the application of the use of ion-selective electrodes has expanded in the field of pharmaceutical analyses due to their distinction from other sensors in their high selectivity and low cost of measurement, in addition to their high measurement sensitivity. Cost-effective, reliable, and robust all-solid-state potentiometric selective electrodes were designed, characterized, and successfully used for pholcodine determination. The design of the sensor device was based on the use of a screen-printed electrode modified with multiwalled carbon nanotubes (MWCNTs) as a solid-contact transducer. Tailored pholcodine (PHO) molecularly imprinted polymers (MIPs) were prepared, characterized, and used as sensory receptors in the presented potentiometric sensing devices. The sensors exhibited a sensitivity of 31.6 ± 0.5 mV/decade (n = 5, R2 = 0.9980) over the linear range of 5.5 × 10−6 M with a detection limit of 2.5 × 10−7 M. Real serum samples in addition to pharmaceutical formulations containing PHO were analyzed, and the results were compared with those obtained by the conventional standard liquid chromatographic approach. The presented analytical device showed an outstanding efficiency for fast, direct, and low-cost assessment of pholcodine levels in different matrices.


Sign in / Sign up

Export Citation Format

Share Document