scholarly journals Absence of lateral gastrocnemius activity and differential motor unit behavior in soleus and medial gastrocnemius during standing balance

2014 ◽  
Vol 116 (2) ◽  
pp. 140-148 ◽  
Author(s):  
Martin E. Héroux ◽  
Christopher J. Dakin ◽  
Billy L. Luu ◽  
John Timothy Inglis ◽  
Jean-Sébastien Blouin

In a standing position, the vertical projection of the center of mass passes in front of the ankle, which requires active plantar-flexor torque from the triceps surae to maintain balance. We recorded motor unit (MU) activity in the medial (MG) and lateral (LG) gastrocnemius muscle and the soleus (SOL) in standing balance and voluntary isometric contractions to understand the effect of functional requirements and descending drive from different neural sources on motoneuron behavior. Single MU activity was recorded in seven subjects with wire electrodes in the triceps surae. Two 3-min standing balance trials and several ramp-and-hold contractions were performed. Lateral gastrocnemius MU activity was rarely observed in standing. The lowest thresholds for LG MUs in ramp contractions were 20–35 times higher than SOL and MG MUs ( P < 0.001). Compared with MUs from the SOL, MG MUs were intermittently active ( P < 0.001), had higher recruitment thresholds ( P = 0.022), and greater firing rate variability ( P < 0.001); this difference in firing rate variability was present in standing balance and isometric contractions. In SOL and MG MUs, both recruitment of new MUs ( R2 = 0.59–0.79, P < 0.01) and MU firing rates ( R2 = 0.05–0.40, P < 0.05) were associated with anterior-posterior and medio-lateral torque in standing. Our results suggest that the two heads of the gastrocnemius may operate in different ankle ranges with the larger MG being of primary importance when standing, likely due to its fascicle orientation. These differences in MU discharge behavior were independent of the type of descending neural drive, which points to a muscle-specific optimization of triceps surae motoneurons.

1987 ◽  
Vol 57 (4) ◽  
pp. 1227-1245 ◽  
Author(s):  
R. C. Foehring ◽  
G. W. Sypert ◽  
J. B. Munson

We tested whether the muscle innervated may influence the expression of motoneuron electrical properties. Properties of individual motor units were examined following cross-reinnervation (X-reinnervation) of cat lateral gastrocnemius (LG) and soleus muscles by the medial gastrocnemius (MG) nerve. We examined animals at two postoperative times: 9-10 wk (medX) and 9-11 mo (longX). For comparison, normal LG and soleus motoneuron properties were also studied. Motor units were classified on the basis of their contractile responses as fast contracting fatigable, fast intermediate fast contracting fatigue resistant, and slow types FF, FI, FR, or S, respectively) (9, 21). Motoneuron electrical properties (rheobase, input resistance, axonal conduction velocity, afterhyperpolarization) were measured. After 9-11 mo, MG motoneurons that innervated LG muscle showed recovery of electrical properties similar to self-regenerated MG motoneurons. The relationships between motoneuron electrical properties were largely similar to self-regenerated MG. For MG motoneurons that innervated LG, motoneuron type (65) predicted motor-unit type in 74% of cases. LongX-soleus motoneurons differed from longX-LG motoneurons or self-regenerated MG motoneurons in mean values for motoneuron electrical properties. The differences in overall means reflected the predominance of type S motor units. The relationships between motoneuron electrical properties were also different than in self-regenerated MG motoneurons. In all cases, the alterations were in the direction of properties of type S units, and the relationship between normal soleus motoneurons and their muscle units. Within motor-unit types, the mean values were typical for that type in self-regenerated MG. Motoneuron type (65) was a fairly strong predictor of motor-unit type in longX soleus. MG motoneurons that innervated soleus displayed altered values for axonal conduction velocity, rheobase, and input resistance, which could indicate incomplete recovery from the axotomized state. However, although mean afterhyperpolarization (AHP) half-decay time was unaltered by axotomy (25), this parameter was significantly lengthened in MG motoneurons that innervated soleus muscle. There were, however, individual motoneuron-muscle-unit mismatches, which suggested that longer mean AHP half-decay time may also be due to incomplete recovery of a subpopulation of motoneurons. Those MG motoneurons able to specify soleus muscle-fiber type exhibited motoneuron electrical properties typical of that same motoneuron type in self-regenerated MG.(ABSTRACT TRUNCATED AT 400 WORDS)


1996 ◽  
Vol 75 (1) ◽  
pp. 51-59 ◽  
Author(s):  
K. E. Tansey ◽  
A. K. Yee ◽  
B. R. Botterman

1. The aim of this study was to examine the extent of muscle-unit force modulation due to motoneuron firing-rate variation in type-identified motor units of the cat medial gastrocnemius (MG) muscle, and to investigate the contribution of muscle-unit force modulation to whole-muscle force regulation. The motoneuron discharge patterns recorded from 8 pairs of motor units during 12 smoothly graded muscle contractions evoked by stimulation of the mesencephalic locomotor region (MLR) were used to reactivate those units in isolation to estimate what their force profiles would have been like during the evoked whole-muscle contractions. 2. For most motor units, muscle-unit force modulation was similar to motoneuron firing-rate modulation, in that muscle-unit force increased over a limited range (120-600 g) of increasing whole-muscle tension and was then maintained at a near maximal (> 70%) output level as muscle force continued to rise. Most muscle units also decreased their force outputs over a slightly larger range of declining whole-muscle force before relaxing. This second finding was best explained by the counterclockwise hysteresis recorded in the motor units' frequency-tension (f-t) relationships. 3. In those instances when whole-muscle force fluctuated just above the recruitment threshold of a motor unit, a substantial percentage (10-25%) of the change in whole-muscle force could be accounted for by force modulation in that motor unit alone. This finding suggested that few motor units in the pool were simultaneously simultaneously undergoing force modulation. To evaluate this possibility, the extent of parallel muscle-unit force modulation within the 8 pairs of simultaneously active motor units was evaluated. As with parallel motoneuron firing-rate modulation, the extent of parallel muscle-unit force modulation was limited to unit pairs of the same physiological type and recruitment threshold. In several instances, pairs of motor units displayed parallel motoneuron firing-rate modulation but did not show parallel muscle-unit force modulation because of the nature of the motor units' f-t relationships. 4. The limited extent of parallel muscle-unit force modulation seen in these experiments implies that the major strategy for force modulation in the cat MG muscle, involving contractions estimated to reach 30-40% of maximum, may be motor-unit recruitment rather than motor-unit firing-rate variation with resulting force modulation. Given, however, that the majority of motor units are already recruited at these output levels (< 40%), it is proposed that motor-unit firing-rate variation with resulting force modulation may take over as the major muscle force modulating strategy at higher output levels.


1993 ◽  
Vol 70 (4) ◽  
pp. 1585-1592 ◽  
Author(s):  
J. S. Carp

1. Homonymous and heteronymous monosynaptic composite excitatory postsynaptic potentials (EPSPs) were evaluated by intracellular recordings from 89 motoneurons innervating triceps surae (n = 59) and more distal (n = 30) muscles in 14 pentobarbital-anesthetized monkeys (Macaca nemestrina). 2. Homonymous EPSPs were found in all motoneurons tested. The mean values +/- SD for maximum EPSP amplitude of triceps surae motoneurons were 2.5 +/- 1.3, 1.8 +/- 1.3 and 4.5 +/- 2.0 mV for medial gastrocnemius, lateral gastrocnemius, and soleus motoneurons, respectively. Heteronymous EPSPs were almost always smaller than their corresponding homonymous EPSPs. 3. Triceps surae EPSP amplitude was larger in motoneurons with higher input resistance. However, this relationship was weak, suggesting that factors related to input resistance play a limited role in determining the magnitude of the EPSP. 4. The mean ratio +/- SD of the amplitude of the EPSP elicited by combined stimulation of all triceps surae nerves to the amplitude of the algebraic sum of the three individual EPSPs was 0.95 +/- 0.05. This ratio was greater in motoneurons with lower rheobase. 5. Some patterns of synaptic connectivity in the macaque are consistent with previously reported differences between primates and cat (e.g., heteronymous EPSPs elicited by medial gastrocnemius nerve stimulation in soleus motoneurons are small in macaque and other primates but large in cat). However, no overall pattern emerges from a comparison of the similarities and differences in EPSPs among species in which they have been studied (i.e., macaque, baboon, and cat). That is, there are no two species in which EPSP properties are consistently similar to each other, but different from those of the third species.(ABSTRACT TRUNCATED AT 250 WORDS)


2006 ◽  
Vol 3 (9) ◽  
pp. 533-544 ◽  
Author(s):  
James M Wakeling ◽  
Katrin Uehli ◽  
Antra I Rozitis

This study investigates the motor unit recruitment patterns between and within muscles of the triceps surae during cycling on a stationary ergometer at a range of pedal speeds and resistances. Muscle activity was measured from the soleus (SOL), medial gastrocnemius (MG) and lateral gastrocnemius (LG) using surface electromyography (EMG) and quantified using wavelet and principal component analysis. Muscle fascicle strain rates were quantified using ultrasonography, and the muscle–tendon unit lengths were calculated from the segmental kinematics. The EMG intensities showed that the body uses the SOL relatively more for the higher-force, lower-velocity contractions than the MG and LG. The EMG spectra showed a shift to higher frequencies at faster muscle fascicle strain rates for MG: these shifts were independent of the level of muscle activity, the locomotor load and the muscle fascicle strain. These results indicated that a selective recruitment of the faster motor units occurred within the MG muscle in response to the increasing muscle fascicle strain rates. This preferential recruitment of the faster fibres for the faster tasks indicates that in some circumstances motor unit recruitment during locomotion can match the contractile properties of the muscle fibres to the mechanical demands of the contraction.


1996 ◽  
Vol 75 (1) ◽  
pp. 38-50 ◽  
Author(s):  
K. E. Tansey ◽  
B. R. Botterman

1. The aim of this study was to examine the nature of motoneuron firing-rate modulation in type-identified motor units during smoothly graded contractions of the cat medial gastrocnemius (MG) muscle evoked by stimulation of the mesencephalic locomotor region (MLR). Motoneuron discharge patterns, firing rates, and the extent of firing-rate modulation in individual units were studied, as was the extent of concomitant changes in firing rates within pairs of simultaneously active units. 2. In 21 pairs of simultaneously active motor units, studied during 41 evoked contractions, the motoneurons' discharge rates and patterns were measured by processing the cells' recorded action potentials through windowing devices and storing their timing in computer memory. Once recruited, most motoneurons increased their firing rates over a limited range of increasing muscle tension and then maintained a fairly constant firing rate as muscle force continued to rise. Most motoneurons also decreased their firing rates over a slightly larger, but still limited, range of declining muscle force before they were derecruited. Although this was the most common discharge pattern recorded, several other interesting patterns were also seen. 3. The mean firing rate for slow twitch (type S) motor units (27.8 imp/s, 5,092 activations) was found to be significantly different from the mean firing rate for fast twitch (type F) motor units (48.4 imp/s, 11,272 activations; Student's t-test, P < 0.001). There was no significant difference between the mean firing rates of fast twitch, fatigue-resistant (type FR) and fast twitch, fatigable (type FF) motor units. When the relationship between motoneuron firing rate and whole-muscle force was analyzed, it was noted that, in general, smaller, lower threshold motor units began firing at lower rates and reached lower peak firing rates than did larger, higher threshold motor units. These results confirm both earlier experimental observations and predictions made by other investigators on the basis of computer simulations of the cat MG motor pool, but are in contrast to motor-unit discharge behavior recorded in some human motor-unit studies. 4. The extent of concomitant changes in firing rate within pairs of simultaneously active motor units was examined to estimate the extent of simultaneous motoneuron firing-rate modulation across the motoneuron pool. A smoothed (5 point sliding average) version of the two motoneurons' instantaneous firing rates was plotted against each other, and the slope and statistical significance of the relationship was determined. In 16 motor-unit pairs, the slope of the motoneurons' firing-rate relationship was significantly distinct from 0. Parallel firing-rate modulation (< 10-fold difference in firing rate change reflected by a slope of > 0.1) was noted only in pairs containing motor units of like physiological type and then only if they were of similar recruitment threshold. 5. Other investigators have demonstrated that changes in a motoneuron's "steady-state" firing rate predictably reflect changes in the amount of effective synaptic current that cell is receiving. The finding in the present study of limited parallel firing-rate modulation between simultaneously active motoneurons would suggest that changes in the synaptic drive to the various motoneurons of the pool is unevenly distributed. This finding, in addition to the findings of orderly motor-unit recruitment and the relationship between motor-unit recruitment threshold and motoneuron firing rate, cannot be adequately accommodated for by the existing models of the synaptic organization in motoneuron pools. Therefore a new model of the synaptic organization within the motoneuron pool has been proposed.


1987 ◽  
Vol 57 (4) ◽  
pp. 1210-1226 ◽  
Author(s):  
R. C. Foehring ◽  
G. W. Sypert ◽  
J. B. Munson

This study addresses two questions: is reinnervation of mammalian skeletal muscle selective with respect to motor-unit type? And to what degree may muscle-unit contractile properties be determined by the motoneuron? Properties of individual motor units were examined following cross-reinnervation (X-reinnervation) of lateral gastrocnemius (LG) and soleus muscles by the medial gastrocnemius (MG) nerve in the cat. We examined animals at two postoperative times: 9-10 wk (medX) and 9-11 mo (longX). For comparison, properties of normal LG and soleus motor units were studied. Motor units were classified on the basis of their contractile response as fast contracting fatigable, fast intermediate, fast contracting fatigue resistant, or slow (types FF, FI, FR, or S, respectively) (13,29). Muscle fibers were classified on the basis of histochemical properties as fast glycolytic, fast oxidative glycolytic, or slow oxidative (types FG, FOG, or SO, respectively) (61). Reinnervation of LG and soleus was not selective with respect to motor-unit type. Both muscles were innervated by a full complement of MG motoneuron types, apparently in normal MG proportions. MG motoneurons determined LG muscle fibers' properties to a similar degree as reinnervated MG muscle fibers. In contrast, soleus muscle fibers "resisted" the influence of MG motoneurons. Thus, although longX-reinnervated LG muscle (longX LG) had a motor-unit type distribution similar to normal or self-reinnervated MG, longX soleus contained predominantly type S motor units. Overall mean values for muscle-unit contractile properties reflected this motor-unit type distribution. Muscle units in longX LG and longX soleus had contractile properties typical of the same motor-unit type in normal LG or soleus, respectively. Motor-unit types were recognizable at 10 wk X-reinnervation, although muscle-unit tensions were lower than after 10 mo. The proportions of fast and slow motor units in medX LG were similar to longX LG, although a greater proportion of fast units were resistant to fatigue at 10 wk. There were fewer fast units in medX soleus than longX soleus, which suggested that motor-unit type conversion or innervation of muscle fibers by fast motoneurons is not complete at 10 wk. We conclude that reinnervation of the LG and soleus muscles by MG motoneurons was not selective with respect to motor-unit type. MG motoneurons determined LG muscle properties to a similar degree as self-reinnervated MG muscle fibers. Soleus muscle fibers resisted the influence of MG motoneurons, representing a limit to neural determination of muscle properties.


2013 ◽  
Vol 110 (11) ◽  
pp. 2592-2606 ◽  
Author(s):  
Renato N. Watanabe ◽  
Fernando H. Magalhães ◽  
Leonardo A. Elias ◽  
Vitor M. Chaud ◽  
Emanuele M. Mello ◽  
...  

This study focuses on neuromuscular mechanisms behind ankle torque and EMG variability during a maintained isometric plantar flexion contraction. Experimentally obtained torque standard deviation (SD) and soleus, medial gastrocnemius, and lateral gastrocnemius EMG envelope mean and SD increased with mean torque for a wide range of torque levels. Computer simulations were performed on a biophysically-based neuromuscular model of the triceps surae consisting of premotoneuronal spike trains (the global input, GI) driving the motoneuron pools of the soleus, medial gastrocnemius, and lateral gastrocnemius muscles, which activate their respective muscle units. Two types of point processes were adopted to represent the statistics of the GI: Poisson and Gamma. Simulations showed a better agreement with experimental results when the GI was modeled by Gamma point processes having lower orders (higher variability) for higher target torques. At the same time, the simulations reproduced well the experimental data of EMG envelope mean and SD as a function of mean plantar flexion torque, for the three muscles. These results suggest that the experimentally found relations between torque-EMG variability as a function of mean plantar flexion torque level depend not only on the intrinsic properties of the motoneuron pools and the muscle units innervated, but also on the increasing variability of the premotoneuronal GI spike trains when their mean rates increase to command a higher plantar flexion torque level. The simulations also provided information on spike train statistics of several hundred motoneurons that compose the triceps surae, providing a wide picture of the associated mechanisms behind torque and EMG variability.


2004 ◽  
Vol 82 (8-9) ◽  
pp. 599-609 ◽  
Author(s):  
Daniel McDonnall ◽  
Gregory A Clark ◽  
Richard A Normann

Recruitment of force via independent asynchronous firing of large numbers of motor units produces the grace and endurance of physiological motion. We have investigated the possibility of reproducing this physiological recruitment strategy by determining the selectivity of access to large numbers of independent motor units through intrafascicular multielectrode stimulation (IFMS) of the peripheral nerve. A Utah Slanted Electrode Array containing 100, 0.5–1.5 mm-long penetrating electrodes was inserted into the sciatic nerve of a cat, and forces generated by the 3 heads of triceps surea in response to electrical stimulation of the nerve were monitored via force transducers attached to their tendons. We found a mean of 17.4 ± 4.9 (mean ± SEM) electrodes selectively excited maximal forces in medial gastrocnemius before exciting another muscle. Among electrodes demonstrating selectivity at threshold, a mean of 7.3 ± 2.7 electrodes were shown to recruit independent populations of motor units innervating medial gastrocnemius (overlap < 20%). Corresponding numbers of electrodes were reported for lateral gastrocnemius and soleus, as well. We used these stimulation data to emulate physiological recruitment strategies, and found that independent motor unit pool recruitment approximates physiological activation more closely than does intensity-based recruitment or frequency-based recruitment.Key words: functional neuromuscular stimulation (FNS), microelectrode array, neuroprosthesis, intrafascicular multielectrode stimulation (IFMS).


Author(s):  
Shun Kunugi ◽  
Ales Holobar ◽  
Tsutomu Kodera ◽  
Heishiro Toyoda ◽  
Kohei Watanabe

Different neurophysiological strategies are used to perform angle adjustments during motor tasks such as car driving and force-control tasks using a fixed-rigid pedal. However, the difference in motor unit behavior in response to an increasing exerted force between tasks is unknown. This study aimed to investigate the difference in motor unit responsiveness on increasing force between force and position tasks. Twelve healthy participants performed ramp and hold contractions during ankle plantarflexion at 20 and 30% of the maximal voluntary contraction using a rigid pedal (force task) and a free pedal with an inertial load (position task). High-density surface electromyograms were recorded of the medial gastrocnemius muscle and decomposed into individual motor unit firing patterns. Ninety and 109 motor units could be tracked between different target torques in each task. The mean firing rate increased and firing rate variability decreased on 10% maximal voluntary contraction force gain during both force and position tasks. There were no significant differences in these responses between the two tasks. Our results suggest that the motor unit firing rate is similarly regulated between force and position tasks in the medial gastrocnemius muscle with an increase in the exerted force.


1983 ◽  
Vol 49 (4) ◽  
pp. 922-931 ◽  
Author(s):  
J. E. Zengel ◽  
S. A. Reid ◽  
G. W. Sypert ◽  
J. B. Munson

1. Composite group Ia excitatory postsynaptic potentials (EPSPs) produced by heteronymous nerve stimulation were recorded from triceps surae motoneurons of barbiturate-anesthetized cats. Motoneuron rheobase, input resistance, and axonal conduction velocity were measured, and motor units were classified on the basis of the mechanical responses of their muscle units. 2. The amplitude of EPSPs recorded from 33 medial gastrocnemius (MG) motoneurons ranged from 0.6 to 4.3 mV. The mean EPSP amplitude differed among the major MG motor-unit types, increasing in the order fast twitch, fast fatiguing (FF); fast twitch, fatigue resistant (FR); slow twitch, fatigue resistant (S) (FF less than FR less than S). The amplitude of EPSPs recorded from 15 soleus motoneurons ranged from 0.3 to 3.4 mV, with a mean of 1.4 mV. 3. Presynaptic inhibition of EPSPs was produced by trains of conditioning volleys in the posterior biceps-semitendinosus (PBST) nerve. In 33 MG cells PBST conditioning stimulation reduced the amplitude of EPSPs by 11-50%, with a mean inhibition of 27%. The amplitude of EPSPs in 15 soleus motoneurons was decreased by 5-84%, with a mean inhibition of 37%. 4. When the magnitude of presynaptic inhibition was expressed as percent inhibition, there was no relation between presynaptic inhibition and either motor-unit type or the amplitude of the EPSP. However, when presynaptic inhibition was expressed as the absolute amount of inhibition in millivolts, the magnitude of inhibition was highly correlated with EPSP amplitude both across the entire triceps surae population (MG, lateral gastrocnemius, soleus) as well as within each muscle population. This correlation was also significant within the MG FF and FR motor-unit populations. 5. We conclude that EPSP amplitude and not motor-unit type is the major determinant of the magnitude of presynaptic inhibition. However, because of the effect of motor-unit type on EPSP amplitude, the net effect is that presynaptic inhibition increases in the order FF less than FR less than S.


Sign in / Sign up

Export Citation Format

Share Document