scholarly journals A Validated Stability Indicating RP-HPLC Method Development and Validation for Simultaneous Estimation of Aliskiren Hemifumarate and Amlodipine Besylate in Pharmaceutical Dosage Form

2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Chinnalalaiah Runja ◽  
P. Ravikumar ◽  
Srinivasa Rao Avanapu

The present study describes the stability indicating RP-HPLC method for simultaneous estimation of aliskiren hemifumarate and amlodipine besylate in pharmaceutical dosage forms. The proposed RP-HPLC method was developed by using waters 2695 separation module equipped with PDA detector and chromatographic separation was carried on C-8 Inertsil ODS (150 × 4.6 mm, 5 µ) column at a flow rate of 1 mL/min and the run time is 10 min. The mobile phase consisted of phosphate buffer and acetonitrile in the ratio of 40 : 60% v/v and pH was adjusted to 3 with orthophosphoric acid and eluents were scanned using PDA detector at 237 nm. The retention time of aliskiren and amlodipine was found to be 3.98 and 5.14 min, respectively. A linearity response was observed in the concentration range of 30–225 µg/mL for aliskiren and 2–15 µg/mL for amlodipine, respectively. Limit of detection and limit of quantification for aliskiren are 0.161 µg/mL and 0.489 µg/mL and for amlodipine are 0.133 µg/mL and 0.404 µg/mL, respectively. The stability indicating method was developed by subjecting the drugs to stress conditions such as acid and base hydrolysis, oxidation, and photo- and thermal degradation and the degraded products formed were resolved successfully from the samples.

Author(s):  
Vaishali Mistry ◽  
Rohan Mishra

Objective: This study describes the stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous estimation of betahistine dihydrochloride and domperidone in pharmaceutical dosage forms.Methods: The proposed RP-HPLC method was developed using Shimadzu Prominence-i LC-2030 HPLC system equipped with UV detector and chromatographic operation was carried on Shim-pack C18 (250 mm×4.6 mm, 5 μ) column at a flow rate of 1 ml/min and the run time was 10 min. The mobile phase consisted of methanol and water in the ratio of 80:20% v/v and eluents were scanned using a UV detector at 244 nm.Results: The retention time of betahistine dihydrochloride and domperidone was found to be 2.3 and 3.6 min, respectively. A linearity response was observed in the concentration range of 9.6 μg/ml–22.4 μg/ml for betahistine dihydrochloride and 6–14 μg/ml for domperidone, respectively. Limit of detection and limit of quantification for betahistine dihydrochloride were 0.52 μg/ml and 1.58 μg/ml and for domperidone are 0.64 μg/ml and 1.94 μg/ml, respectively.Conclusion: The stability-indicating method was developed by subjecting drugs to stress conditions such as acid and base hydrolysis, oxidation, photo and thermal degradation, and degraded products formed were resolved successfully from samples.


Author(s):  
Rajesh Babu Y. ◽  
Appala Raju N.

The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Pazopanib hydrochloride in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Pazopanib hydrochloride in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Pazopanib hydrochloride in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.


Author(s):  
Y. Rajesh Babu ◽  
N. Appalaraju

The aim of this paper was to develop and validate the stability indicating RP-HPLC method for the determination of Imatinib mesylate in bulk and pharmaceutical dosage forms. A simple, accurate, precise, sensitive and stability indicating RP-HPLC method has been developed for the determination of Imatinib mesylate in bulk drug and pharmaceutical dosage form, in which separations are done using develosil C18, 5μm, 150 × 4.6mm i.d. column at a flow rate of 1.0mL/min with an injection volume of 20μL. The beer’s law was obeyed over the concentration range of 5 - 35μg/mL. The correlation coefficient was found to be 0.996 and it showed good linearity, reproducibility, precision in this concentration range. The % recovery values were found to be within the limits, which showed that the method was accurate. The LOD and LOQ were calculated using statistical methods. The % RSD values were less than 2. The developed method was successfully applied for determination of Imatinib mesylate in pharmaceutical dosage form. The results obtained are in good agreement with those obtained by using the standard method.