scholarly journals SIMULTANEOUS ESTIMATION, VALIDATION, AND FORCED DEGRADATION STUDIES OF BETAHISTINE DIHYDROCHLORIDE AND DOMPERIDONE IN A PHARMACEUTICAL DOSAGE FORM USING RP-HPLC METHOD

Author(s):  
Vaishali Mistry ◽  
Rohan Mishra

Objective: This study describes the stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous estimation of betahistine dihydrochloride and domperidone in pharmaceutical dosage forms.Methods: The proposed RP-HPLC method was developed using Shimadzu Prominence-i LC-2030 HPLC system equipped with UV detector and chromatographic operation was carried on Shim-pack C18 (250 mm×4.6 mm, 5 μ) column at a flow rate of 1 ml/min and the run time was 10 min. The mobile phase consisted of methanol and water in the ratio of 80:20% v/v and eluents were scanned using a UV detector at 244 nm.Results: The retention time of betahistine dihydrochloride and domperidone was found to be 2.3 and 3.6 min, respectively. A linearity response was observed in the concentration range of 9.6 μg/ml–22.4 μg/ml for betahistine dihydrochloride and 6–14 μg/ml for domperidone, respectively. Limit of detection and limit of quantification for betahistine dihydrochloride were 0.52 μg/ml and 1.58 μg/ml and for domperidone are 0.64 μg/ml and 1.94 μg/ml, respectively.Conclusion: The stability-indicating method was developed by subjecting drugs to stress conditions such as acid and base hydrolysis, oxidation, photo and thermal degradation, and degraded products formed were resolved successfully from samples.

2014 ◽  
Vol 2014 ◽  
pp. 1-7 ◽  
Author(s):  
Chinnalalaiah Runja ◽  
P. Ravikumar ◽  
Srinivasa Rao Avanapu

The present study describes the stability indicating RP-HPLC method for simultaneous estimation of aliskiren hemifumarate and amlodipine besylate in pharmaceutical dosage forms. The proposed RP-HPLC method was developed by using waters 2695 separation module equipped with PDA detector and chromatographic separation was carried on C-8 Inertsil ODS (150 × 4.6 mm, 5 µ) column at a flow rate of 1 mL/min and the run time is 10 min. The mobile phase consisted of phosphate buffer and acetonitrile in the ratio of 40 : 60% v/v and pH was adjusted to 3 with orthophosphoric acid and eluents were scanned using PDA detector at 237 nm. The retention time of aliskiren and amlodipine was found to be 3.98 and 5.14 min, respectively. A linearity response was observed in the concentration range of 30–225 µg/mL for aliskiren and 2–15 µg/mL for amlodipine, respectively. Limit of detection and limit of quantification for aliskiren are 0.161 µg/mL and 0.489 µg/mL and for amlodipine are 0.133 µg/mL and 0.404 µg/mL, respectively. The stability indicating method was developed by subjecting the drugs to stress conditions such as acid and base hydrolysis, oxidation, and photo- and thermal degradation and the degraded products formed were resolved successfully from the samples.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (09) ◽  
pp. 40-47
Author(s):  
B. N Nalluri ◽  
◽  
B. Mrudula ◽  
K Chitralatha ◽  
S. A Sultana ◽  
...  

The present paper describes a sensitive and simple RP-HPLC-PDA method for the simultaneous estimation of Naproxen Sodium (NPX) and Diphenhydramine Hydrochloride (DPH) in the presence of their degradants. The drugs were subjected to stress conditions (forced degradation) to show the stability-indicating power of the method. The separation was achieved on Inertsil ODS C18 column (250×4.6mm, 5μ). The optimized liquid chromatographic conditions were found to be a mobile phase of 15mM ammonium acetate buffer: acetonitrile (60:40V/V) combination at a flow rate of 1.0 mL/min in isocratic mode with an injection volume of 10µL. The proposed method provided retention times of 4.6 and 10.8min, with linear responses over a range of 60-140μg/mL and 10-30μg/mL and regression coefficient (R2) of 0.999 and 0.996 respectively for NPX and DPH. No interference from other components of pharmaceutical dosage form and degradants was observed. The method was validated as per ICH guidelines and was successfully applied for the simultaneous estimation of both the drugs in bulk and tablet preparations.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (4) ◽  
pp. 50-55
Author(s):  
Shahbaz Rathor ◽  
Atul Sherje ◽  

Simple and precise stability indicating RP-HPLC method for the quantitative determination of tizanidinehydrochloride (TZN) in pharmaceutical dosage form was developed and validated. The separation was achieved using Atlantis C18 column (250 x 4.6 mm, 5µm) at 25 °C using a mobile phase containing 20mM KH2 PO4 (pH 3.5):methanol in the ratio of 30:70 V/V at 0.8 mL/min flow rate and 315nm detection wavelength. The retention time for TZN was 3.7 min and showed linearity in the 5-40µg/mL range with R2 >0.99. The drug was subjected to acid/ base hydrolysis, oxidative and thermal degradation to establish stability indicating method. The method was validated as per ICHQ2 (R1) guidelines. The method was accurate, precise, and specific for TZN estimation. In stress studies, the drug was found to be stable to acid/alkaline hydrolysis, oxidation, and thermal degradation conditions. Thus, the reported method can be used as a stability-indicating method for quality control and routine analysis of TZN.


Author(s):  
Vaishali Mistry ◽  
Akshay Yelwe ◽  
Amey Deshpande

Objective: The present study describes the stability indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous estimation of 5-fluorouracil and tegafur in pharmaceutical dosage forms.Method: 5-fluorouracil and tegafur the propose RP-HPLC method were developed by using Shimadzu Prominence-i LC-2030 HPLC system equipped with UV detector and chromatographic separation was carried on shim-pack gist c18 (250 × 4.6 mm, 5 μ) column at a flow rate of 1 ml/min and the run time was 10 min. The mobile phase consisted of methanol and water in the ratio of 50:50% v/v and elements were scanned using a UV detector at 271 nm.Result: The retention time of 5-fluorouracil and tegafur was found to be 2.74 and 3.66 min, respectively. A linearity response was observed in the concentration range of 13.4 μg/ml–31.3 μg/ml for 5-fluorouracil and 6 μg/ml–14 μg/ml for tegafur, respectively. Limit of detection and limit of quantification of 5-fluorouracil were 10.97 μg/ml and 33.26 μg/ml and for tegafur are 4.89 μg/ml and 14.83 μg/ml, respectively.Conclusion: The stability indicating that the method was developed by subjecting drugs to stress conditions such as acid and base hydrolysis, oxidation, photo and thermal degradation, and degraded products formed were resolved successfully from samples.


2013 ◽  
Vol 2013 ◽  
pp. 1-9 ◽  
Author(s):  
Chinmoy Roy ◽  
Jitamanyu Chakrabarty

A simple, specific, precise, and accurate RP-HPLC method has been developed and validated for simultaneous estimation of Methylparaben (MP), Ketoconazole (KT), and Mometasone Furoate (MF) topical pharmaceutical dosage formulation. The separation was achieved by Waters X Terra C18 column using mobile phase consisting of buffer (triethyl amine in water, pH adjusted to 6.5 with glacial acetic acid)-acetonitrile (40 : 60, v/v) at a flow rate of 1.5 mL/min and detection at 250 nm. The method showed linearity with correlation coefficient <0.9999 over the range of 0.12–15.2 μg/mL, 0.67–149.4 μg/mL, and 0.42–7.6 μg/mL for MP, KT, and MF, respectively. The mean recoveries were found to be in the range of 99.9–101.1% for all the components. The method was validated as per the ICH guidelines for linearity, limit of detection, limit of quantification, accuracy, precision, robustness and solution stability. Stability indicating capability of the developed method was established by analyzing forced degradation of samples in which spectral purity of MP, KT, and MF along with separation of degradation products from analytes peak was achieved. The method can be successfully applied for routine analysis of quantitative determination of MP, KT, and MF in pharmaceutical dosage form.


2013 ◽  
Vol 2013 ◽  
pp. 1-7 ◽  
Author(s):  
Ramakrishna Kommana ◽  
Praveen Basappa

The present paper describes the development of quick stability indicating RP-HPLC method for the simultaneous estimation of codeine phosphate and chlorpheniramine maleate in the presence of its degradation products, generated from forced degradation studies. The developed method separates codeine phosphate and chlorpheniramine maleate in impurities/degradation products. Codeine phosphate and chlorpheniramine maleate and their combination drug product were exposed to acid, base, oxidation, dry heat, and photolytic stress conditions, and the stressed samples were analysed by proposed method. The proposed HPLC method utilizes the Shimadzu HPLC system on a Phenomenex C18 column (, 5 μ) using a mixture of 1% o-phosphoric acid in water : acetonitrile : methanol (78 : 10 : 12) mobile phase with pH adjusted to 3.0 in an isocratic elution mode at a flow rate of 1 mL/min, at 23°C with a load of 20 μL. The detection was carried out at 254 nm. The retention time of codeine phosphate and chlorpheniramine maleate was found to be around 3.47 min and 9.45 min, respectively. The method has been validated with respect to linearity, robustness, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ). The developed validated stability indicating HPLC method was found to be simple, accurate, and reproducible for the determination of instability of these drugs in bulk and commercial products.


Author(s):  
Swathi P. ◽  
S. Vidyadhara ◽  
R. L. C. Sasidhar ◽  
K. Kalyan Chakravarthi

Objective: The objective and purpose of the analysis have sensibly assessed by selecting of a rapid and sensitive RP-HPLC method for Entecavir in bulk and pharmaceutical dosage form by using the most commonly employed C-18column with UV detection.Methods: In estimation by RP-HPLC method Agilent 1120 compact LC system with variable programmable UV detector and Rheodyne injector with 20 µl fixed loop was used for the chromatographic separation. The mode of operation was isocratic with the components of a solution consisting of methanol: acetonitrile(70:30v/v) and triethanolamine (2-4drops)at the flow rate of 1.2 ml/min and run time was 10 min. Forced degradation studies were conducted to evaluate the stability and specificity of the method along with the validation parameters.Results: Validation parameters of HPLC were found at a detection wavelength of 255 nm. Linearity was observed with the concentration range (Beer’s law range) 20-100µg/ml with R2=0.9991. Robustness with detection wavelengths 253 and 257 nm with a flow rate of 1 ml/min and 1.4 ml/min showed good results. The retention time of the drug was 2.64 min and assay showed 98.1%.Conclusion: The proposed RP-HPLC method was validated as per the ICH Q2B Guidelines, and was found to be applicable for routine quantitative analysis of Entecavir by RP-HPLC using UV detector in pharmaceutical dosage forms. The results of linearity, precision, accuracy and specificity, were proved, that does not exceed certain specified limits. The method provides selective quantification with no interference from other formulation excipients. The proposed method was highly sensitive, reproducible, reliable, robust and specific. Therefore, this method is a simple, rapid analysis may actually be more desirable than a more complicated and time-consuming process. The degradation studies at various stress conditions like thermal and hydrolytic, drug gets degraded at a temperature of 80 °c and refluxing with water at 70 °c for 24hours. 


Author(s):  
B. Anjaneyulu Reddy ◽  
Md. Irshad Alam ◽  
Nazia Khanam ◽  
P. R. Adhakrishnanand

Objective: To develop an innovative, rapid, simple, cost effective, stability indicating reverse phase-high performance liquid chromatography (RP-HPLC) method for simultaneous estimation of ledipasvir (LP) and sofosbuvir (SB) in combination pill dosage form. Methods: The method was developed using C8 column, 250 mm x 4.6 mm, 5mm using mobile section comprising of 0.1% (v/v) orthophosphoric acid buffer at pH 2.2 and acetonitrile in the ratio of 45:55 that was pumped through the column at a flow rate of 0.8 ml/min. Temperature was maintained at 30 °C, the effluents were monitored at 260 nm with the help of usage of PDA detector. Results: The retention time of LP and SB were found to be 2.246 min and 3.502 min. The approach was found to be linear with the variety of 9-36 µg/ml and 40-240 μg/ml for LP and SB respectively, the assay of estimated compounds were found to be 99.65% and 99.73% w/v for LP and SB respectively. Conclusion: The pressured samples changed into analyzed and this proposed a technique turned into determined to be particular and stability indicating as no interfering peaks of decay compound and excipients were observed. Hence, the approach was easy and economical that may be efficiently applied for simultaneous estimation of both LP and SB in bulk and combination tablet system.


Sign in / Sign up

Export Citation Format

Share Document