scholarly journals Design of a UHF Antenna for Partial Discharge Detection of Power Equipment

2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
Youyuan Wang ◽  
Junfeng Wu ◽  
Weigen Chen ◽  
Yajun Wang

A single-arm Archimedean spiral antenna that can be directly fed by a 50 Ωcoaxial cable is investigated in this study. Every antenna parameter is optimized under simulation to make the antenna work in the ultra-high frequency band. The influence of dielectric materials, feed cone angle, and antenna duty ratio is also examined. Partial discharge (PD) experiments on several typical artificial insulation defects are conducted, and a single-arm Archimedean spiral antenna and a typical microstrip antenna are utilized for PD measurement. The PD characteristics of different insulation defects are also analyzed. Results show that the designed antenna is suitable for ultra-high frequency monitoring. The detection sensitivity of the single-arm spiral antenna is superior to that of the ordinary microstrip antenna. The former can be utilized in wide-band measurement fields.

2013 ◽  
Vol 816-817 ◽  
pp. 443-445
Author(s):  
Yong Chun Liang ◽  
Zhao Long Qiao ◽  
Zhi Peng Ge ◽  
Teng Jiao Feng

The detection of partial discharge in power cables is an effective method to diagnosis early fault of XLPE cable . When partial discharge occurs, it emits abundant frequency component in ultra-high frequency (UHF) band, and broadband planar spiral antenna is an effective sensor to detect UHF partial discharge signals. High frequency electromagnetic simulation software Ansoft HFSS is used to simulate and analysis planar Equiangular spiral antenna and Archimedean spiral antenna. The simulation results show that the two kinds of antennas work effectively in 400 MHZ ~ 1 GHZ frequency band and are high sensitivity and superior performance. Because of with smaller size and larger gain, the Archimedean spiral antenna is used to detect UHF signals of partial discharge in XLPE cable.


2015 ◽  
Vol 738-739 ◽  
pp. 38-41
Author(s):  
Yu Bing Duan ◽  
Hao Zhang ◽  
Jun Yong ◽  
Bo Yang ◽  
Xiao Li Hu ◽  
...  

This paper summarizes the application situation of the ultra-high frequency (UHF) method in gas insulated switchgear (GIS) partial discharge detection, as well as the differences between internal and external UHF sensors. The performance indicators of internal sensors are introduced, and five main types of internal sensors are discussed and evaluated. In addition, several problems to be solved are posed for researchers.


Sign in / Sign up

Export Citation Format

Share Document