scholarly journals Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Abdallah El-Sayed Allam ◽  
Adham Aboul Fotouh Khalil ◽  
Basma Aly Eltawab ◽  
Wei-Ting Wu ◽  
Ke-Vin Chang

Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves.

2008 ◽  
Vol 6;11 (12;6) ◽  
pp. 885-889 ◽  
Author(s):  
Kenneth P. Botwin

Background: Myofascial pain is defined as pain that originates from myofascial trigger points in skeletal muscle. It is prevalent in regional musculoskeletal pain syndromes, either alone or in combination with other pain generators. The myofascial pain syndrome is one of the largest groups of under diagnosed and under treated medical problems encountered in clinical practice. Trigger points are commonly seen in patients with myofascial pain which is responsible for localized pain in the affected muscles as well as referred pain patterns. Correct needle placement in a myofascial trigger point is vital to prevent complications and improve efficacy of the trigger point injection to help reduce or relieve myofascial pain. In obese patients, these injections may not reach the target tissue. In the cervicothoracic spine, a misguided or misplaced injection can result in a pneumothorax. Here, we describe an ultrasound-guided trigger point injection technique to avoid this potential pitfall. Office based ultrasound-guided injection techniques for musculoskeletal disorders have been described in the literature with regard to tendon, bursa, cystic, and joint pathologies. For the interventionalist, utilizing ultrasound yields multiple advantages technically and practically, including observation of needle placement in real-time, ability to perform dynamic studies, the possibility of diagnosing musculoskeletal pathologies, avoidance of radiation exposure, reduced overall cost, and portability of equipment within the office setting. To our knowledge, the use of ultrasound guidance in performing trigger point injection in the cervicothoracic area, particularly in obese patients, has not been previously reported. Methods: A palpable trigger point in the cervicothoracic musculature was localized and marked by indenting the skin with the tip of a plastic needle cover. The skin was then sterile prepped. Then, using an ultrasound machine with sterile coupling gel and a sterile latex free transducer cover, the musculature in the cervicothoracic spine where the palpable trigger point was detected was visualized. Then utilizing direct live ultrasound guidance, a 25-gauge 1.5 inch needle connected to a 3 mL syringe was placed into the muscle at the exact location of the presumed trigger point. This guidance helps confirm needle placement in muscle tissue and not in an adipose tissue or any other non-musculature structure. Results: The technique is simple to be performed by a pain management specialist who has ultrasound system training. Conclusion: Ultrasound-guided trigger point injections may help confirm proper needle placement within the cervicothoracic musculature. The use of ultrasound-guided trigger point injections in the cervicothoracic musculature may also reduce the potential for a pneumothorax by an improperly placed injection. Key words: Trigger point injection, myofascial pain, ultrasound


Author(s):  
Thibaut Jacques ◽  
Charlotte Brienne ◽  
Simon Henry ◽  
Hortense Baffet ◽  
Géraldine Giraudet ◽  
...  

Abstract Objectives The aim of this study was to assess the feasibility, performance, and complications of a non-surgical, minimally-invasive procedure of deep contraceptive implant removal under continuous ultrasound guidance. Methods The ultrasound-guided procedure consisted of local anesthesia using lidocaine chlorhydrate 1% (10 mg/mL) with a 21-G needle, followed by hydrodissection using NaCl 0.9% (9 mg/mL) and implant extraction using a Hartmann grasping microforceps. The parameters studied were the implant localization, success and complication rates, pain throughout the intervention, volumes of lidocaïne and NaCl used, duration of the procedure, and size of the incision. Between November 2019 and January 2021, 45 patients were referred to the musculoskeletal radiology department for ultrasound-guided removal of a deep contraceptive implant and were all retrospectively included. Results All implants were successfully removed en bloc (100%). The mean incision size was 2.7 ± 0.5 mm. The mean duration of the extraction procedure was 7.7 ± 6.3 min. There were no major complications (infection, nerve, or vessel damage). As a minor complication, 21 patients (46.7%) reported a benign superficial skin ecchymosis at the puncture site, spontaneously regressing in less than 1 week. The procedure was very well-tolerated, with low pain rating throughout (1.0 ± 1.5/10 during implant extraction). Conclusions Minimally invasive removal of deep contraceptive implants under continuous ultrasound guidance alone is feasible, effective, and safe. In the present cohort, all implants were successfully removed, whatever the location, with short procedural time, small incision size, low pain levels, and no significant complications. This procedure could become a gold standard in this indication. Key Points • Minimally invasive removal of deep contraceptive implants under continuous ultrasound guidance alone is feasible, which led to a success rate of 100% whatever the location (even close to neurovascular structures), with only a small skin incision (2.7 ± 0.5 mm). • The procedure was safe, quick, without any major complications, and very well tolerated in terms of pain. • This minimally invasive ultrasound-guided procedure could become the future gold standard for the removal of deep contraceptive implants, as an alternative to surgical extraction, even for implants in difficult locations such as subfascial ones or those close to neurovascular structures.


2019 ◽  
Vol 7 (8) ◽  
pp. 232596711986601 ◽  
Author(s):  
Brennan J. Boettcher ◽  
John H. Hollman ◽  
Michael J. Stuart ◽  
Jonathan T. Finnoff

Background: Adductor longus tendinopathy is a well-known etiology of chronic groin pain in elite athletes. Surgery is indicated for those who fail conservative treatment. No studies to date have evaluated the feasibility of an ultrasound-guided release of the proximal adductor longus tendon. Purpose/Hypothesis: The primary aim of this study was to determine the feasibility of an ultrasound-guided selective adductor longus release with a cutting wire. A secondary aim was to determine safety by avoiding injury to adjacent structures. We hypothesized that the proximal adductor longus tendon can be released under ultrasound guidance with a cutting wire without injury to adjacent neurovascular or genitourinary structures. Study Design: Descriptive laboratory study. Methods: Ten adductor longus tendons (5 cadaveric specimens) from 4 males and 1 female between 76 and 89 years of age with a mean body mass index of 21.9 kg/m2 (range, 16.8-29.6 kg/m2) were used during this study. A single experienced physician sonographer performed ultrasound-guided proximal adductor longus tendon releases on all cadaveric specimens using a cutting wire. Dissection was performed by a second physician to determine the completeness of the tendon transections and to detect injury to adjacent neurovascular or genitourinary structures. Results: All 10 adductor longus tendons were transected. Eight of 10 transections were complete, whereas in 2 transections, >99% of the tendon was transected. There were no injuries to adjacent genitourinary or neurovascular structures. Conclusion: Ultrasound-guided adductor tendon release is feasible and safe in a cadaveric model. Further translational research should be performed to determine whether these results can be replicated in the clinical setting. Clinical Relevance: Adductor longus tendinopathy frequently requires surgical intervention and prolonged time away from sport. The present study suggests that a selective adductor longus tendon release can be performed with ultrasound guidance. This procedure warrants further translational research to explore its use in clinical practice.


2015 ◽  
Vol 3;18 (3;5) ◽  
pp. E411-E415
Author(s):  
Mark C. Kendall

Although pharmacological therapy is the primary treatment modality for trigeminal neuralgia associated pain, ineffective analgesia and dose limiting side effects often prompt patients to seek alternative pharmacological solutions such as interventional nerve blockade. Blockade of the Gasserian ganglion or its branches is an effective analgesic procedure for trigeminal neuralgia, traditionally performed using fluoroscopy or CT imaging. Ultrasonography allows point of care and real time visualization of needle placement within the surrounding anatomical structures. The use of ultrasonography with pulsed radiofrequency therapy for trigeminal neuralgia has not been reported. Our case is a 66-year-old male suffering from trigeminal neuralgia for 4 years that was refractory to pharmacologic therapy. Neurological examination was normal with no sensory deficit. Imaging showed no vascular compression or mass involving the trigeminal nerve. A diagnostic ultrasound-guided trigeminal nerve block via the pterygopalatine fossa with 4 mL of bupivacaine 0.25% and 4 mg dexamethasone provided immediate pain relief (100%) with sustained analgesia >50% at 2 weeks. Pain relief was not sustained at one month, with return to pretreatment symptoms. A series of injections were performed with similar intermittent analgesic effectiveness. The decision was made that the patient was a suitable candidate for pulsed radiofrequency application in the pterygopalatine fossa. We successfully used an alternative approach through the pterygopalatine fossa to treat trigeminal neuralgia using ultrasound guidance in an office setting. Our case demonstrates the utility of ultrasound-guidance pulsed radiofrequency treatment in the pterygopalatine fossa as a potential alternative to other percutaneous techniques for patients with medical refractory trigeminal neuralgia. Key words: Pulsed radiofrequency, trigeminal nerve, ultrasound-guided, trigeminal neuralgia, facial pain


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1615.2-1616
Author(s):  
A. R. Cunha ◽  
C. Mazeda ◽  
R. Aguiar ◽  
A. Barcelos

Background:Sacroiliitis is the hallmark of axial Spondyloarthritis (axSpA). ASAS-EULAR management recommendations for axSpA, consider glucocorticoid injections directed to the local site of musculoskeletal inflammation as a treatment option for pain relief, besides treatment with oral non-steroidal anti-inflammatory (NSAIDs) before starter biotechnological treatment. However, there are few studies to evaluate efficacy of this technique with a small number of patients and a short follow-up. Ultrasonography has been used as a valuable option to guide this technique.Objectives:To evaluate the efficacy and safety of ultrasound-guided injections of sacroiliac joints (SIJs) in patients with sacroiliitis using clinical and laboratory outcomes at baseline and at 4-6thweeks.Methods:This study involved patients with axSpA with acute sacroiliitis, ≥18 and ≤ 65 years old, with body mass index (BMI) < 30kg/m2attending the Rheumatology Outpatient Clinic, which had been poorly controlled (ASDAS>2.1) by conventional therapy (physiotherapy, NSAIDs at maximum tolerated dosing during ≥ 4 weeks). Sociodemographic, clinical (disease duration, BMI, BASDAI, BASFI, ASDAS) and laboratory (CRP) data was collected from the medical records at baseline and at 4-6thweeks.Statistical analyses were conducted using SPSS version 25. Continuous variables were described with mean/median ± standard deviation (SD).SIJs injection was performed, under ultrasound guidance, using standard procedures with 2mL of lidocaine 1% and 40mg of methylprednisolone, with a 22-gauge needle. The procedure was performed by the same operator. Written informed consents were obtained from all patients.Results:We performed eleven sacroiliac injection in eleven consecutive patients (one procedure per patient). Nine patients (81.8%) were female, mean age (±SD) of 40.6(±9.4) years, median disease duration(±SD) of 0.9(±6.2) years and median BMI(±SD) of 24.2(±3.3). Eight patients (72.7%) had Nr-axSpA. All patients were non-responders to NSAIDs.At 4-6thweeks there was a decreased in median (±SD) BASDAI (5.4±1.9 vs 4.1±1.9), BASFI (4.2±1.4 vs 3.5±2.3) and ASDAS (3.2±0.8 vs 2.2±0.6) indexes.Conclusion:As previous studies demonstrated, this technique seems to be safe and quite effective.Our goal is to increase the number of patients undergoing this technique and have a longer follow up to evaluate its efficacy. The study has several limitations: the mid- and long-term effects should be evaluated in the future based on the results of the short-term effects and the study was not conducted as a double-blinded, controlled study.References:[1]van der Heijde D, Burgos-Vargas R, Ramiro S.,et al. ASAS/EULAR recommendations for the management of ankylosing spondylitis. Ann Rheum Dis 2017; 76:978–991[2]Maugars Y, Mathis C, Vilon P, Prost A. Corticosteroid injection of the sacroiliac joint in patients with seronegative spondylarthropathy. Arthritis Rheum 1992; 35:564–8.[3]Pekkafahli MZ, Kiralp MZ, Basekim CC et al. Sacroiliac joint injections performed with sonographic guidance. J Ultrasound Med 2003;22:553–9[4]Klauser A, De Zordo T, Feuchtner G et al. Feasibility of ultrasound-guided sacroiliac joint injection considering sonoanatomic landmarks at two different levels in cadavers and patients. Arthritis Rheum 2008; 59:1618–1624.Disclosure of Interests:Ana Rita Cunha: None declared, Carolina Mazeda: None declared, Renata Aguiar: None declared, Anabela Barcelos Speakers bureau: Bene, Eli-Lilly, Pfizer, MSD, Novartis


2017 ◽  
Vol 01 (01) ◽  
pp. 020-022
Author(s):  
Praveen Vasanthraj ◽  
Varun Bandi ◽  
Venkata Sai ◽  
Manikanthan Shekar

AbstractChronic renal diseases have been on rise with most patients requiring renal transplantation. With advances in treatment, patients undergo hemodialysis through arteriovenous (AV) fistulas and grafts. Thrombosis in these fistulas and grafts are more common and may result in failure. Interventional radiology plays an important role in managing these thromboses through catheter-directed thrombolysis. With success rate of more than 80%, catheter-directed thrombolysis has become the treatment of choice. However, the need of trained personnel, well-equipped catheter laboratories, and expensiveness are its disadvantages. We share our initial experience in two patients in whom we have performed ultrasound-guided percutaneous pulse-spray pharmacomechanical thrombolysis as a day-care procedure. This technique is less expensive, can have a wider outreach, and patients can be benefitted early to avoid new access.


2016 ◽  
Vol 29 (05) ◽  
pp. 386-393 ◽  
Author(s):  
Chiara Bergamino ◽  
Ruth Sanders ◽  
Ursula Fogarty ◽  
Antonella Puggioni ◽  
Clodagh Kearney ◽  
...  

Summary Objectives: To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Methods: Both sacroiliac joints from 10 lumbo sacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomo-graphical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Results: Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤ 2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertrans-verse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Limitations: Safety and efficacy could not be established. Clinical relevance: Cranial and CM ultra-sound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra- articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.


Sign in / Sign up

Export Citation Format

Share Document