scholarly journals Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study

2019 ◽  
Vol 7 (8) ◽  
pp. 232596711986601 ◽  
Author(s):  
Brennan J. Boettcher ◽  
John H. Hollman ◽  
Michael J. Stuart ◽  
Jonathan T. Finnoff

Background: Adductor longus tendinopathy is a well-known etiology of chronic groin pain in elite athletes. Surgery is indicated for those who fail conservative treatment. No studies to date have evaluated the feasibility of an ultrasound-guided release of the proximal adductor longus tendon. Purpose/Hypothesis: The primary aim of this study was to determine the feasibility of an ultrasound-guided selective adductor longus release with a cutting wire. A secondary aim was to determine safety by avoiding injury to adjacent structures. We hypothesized that the proximal adductor longus tendon can be released under ultrasound guidance with a cutting wire without injury to adjacent neurovascular or genitourinary structures. Study Design: Descriptive laboratory study. Methods: Ten adductor longus tendons (5 cadaveric specimens) from 4 males and 1 female between 76 and 89 years of age with a mean body mass index of 21.9 kg/m2 (range, 16.8-29.6 kg/m2) were used during this study. A single experienced physician sonographer performed ultrasound-guided proximal adductor longus tendon releases on all cadaveric specimens using a cutting wire. Dissection was performed by a second physician to determine the completeness of the tendon transections and to detect injury to adjacent neurovascular or genitourinary structures. Results: All 10 adductor longus tendons were transected. Eight of 10 transections were complete, whereas in 2 transections, >99% of the tendon was transected. There were no injuries to adjacent genitourinary or neurovascular structures. Conclusion: Ultrasound-guided adductor tendon release is feasible and safe in a cadaveric model. Further translational research should be performed to determine whether these results can be replicated in the clinical setting. Clinical Relevance: Adductor longus tendinopathy frequently requires surgical intervention and prolonged time away from sport. The present study suggests that a selective adductor longus tendon release can be performed with ultrasound guidance. This procedure warrants further translational research to explore its use in clinical practice.

Author(s):  
Thibaut Jacques ◽  
Charlotte Brienne ◽  
Simon Henry ◽  
Hortense Baffet ◽  
Géraldine Giraudet ◽  
...  

Abstract Objectives The aim of this study was to assess the feasibility, performance, and complications of a non-surgical, minimally-invasive procedure of deep contraceptive implant removal under continuous ultrasound guidance. Methods The ultrasound-guided procedure consisted of local anesthesia using lidocaine chlorhydrate 1% (10 mg/mL) with a 21-G needle, followed by hydrodissection using NaCl 0.9% (9 mg/mL) and implant extraction using a Hartmann grasping microforceps. The parameters studied were the implant localization, success and complication rates, pain throughout the intervention, volumes of lidocaïne and NaCl used, duration of the procedure, and size of the incision. Between November 2019 and January 2021, 45 patients were referred to the musculoskeletal radiology department for ultrasound-guided removal of a deep contraceptive implant and were all retrospectively included. Results All implants were successfully removed en bloc (100%). The mean incision size was 2.7 ± 0.5 mm. The mean duration of the extraction procedure was 7.7 ± 6.3 min. There were no major complications (infection, nerve, or vessel damage). As a minor complication, 21 patients (46.7%) reported a benign superficial skin ecchymosis at the puncture site, spontaneously regressing in less than 1 week. The procedure was very well-tolerated, with low pain rating throughout (1.0 ± 1.5/10 during implant extraction). Conclusions Minimally invasive removal of deep contraceptive implants under continuous ultrasound guidance alone is feasible, effective, and safe. In the present cohort, all implants were successfully removed, whatever the location, with short procedural time, small incision size, low pain levels, and no significant complications. This procedure could become a gold standard in this indication. Key Points • Minimally invasive removal of deep contraceptive implants under continuous ultrasound guidance alone is feasible, which led to a success rate of 100% whatever the location (even close to neurovascular structures), with only a small skin incision (2.7 ± 0.5 mm). • The procedure was safe, quick, without any major complications, and very well tolerated in terms of pain. • This minimally invasive ultrasound-guided procedure could become the future gold standard for the removal of deep contraceptive implants, as an alternative to surgical extraction, even for implants in difficult locations such as subfascial ones or those close to neurovascular structures.


2018 ◽  
Vol 2018 ◽  
pp. 1-9 ◽  
Author(s):  
Abdallah El-Sayed Allam ◽  
Adham Aboul Fotouh Khalil ◽  
Basma Aly Eltawab ◽  
Wei-Ting Wu ◽  
Ke-Vin Chang

Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves.


2020 ◽  
Vol 79 (Suppl 1) ◽  
pp. 1615.2-1616
Author(s):  
A. R. Cunha ◽  
C. Mazeda ◽  
R. Aguiar ◽  
A. Barcelos

Background:Sacroiliitis is the hallmark of axial Spondyloarthritis (axSpA). ASAS-EULAR management recommendations for axSpA, consider glucocorticoid injections directed to the local site of musculoskeletal inflammation as a treatment option for pain relief, besides treatment with oral non-steroidal anti-inflammatory (NSAIDs) before starter biotechnological treatment. However, there are few studies to evaluate efficacy of this technique with a small number of patients and a short follow-up. Ultrasonography has been used as a valuable option to guide this technique.Objectives:To evaluate the efficacy and safety of ultrasound-guided injections of sacroiliac joints (SIJs) in patients with sacroiliitis using clinical and laboratory outcomes at baseline and at 4-6thweeks.Methods:This study involved patients with axSpA with acute sacroiliitis, ≥18 and ≤ 65 years old, with body mass index (BMI) < 30kg/m2attending the Rheumatology Outpatient Clinic, which had been poorly controlled (ASDAS>2.1) by conventional therapy (physiotherapy, NSAIDs at maximum tolerated dosing during ≥ 4 weeks). Sociodemographic, clinical (disease duration, BMI, BASDAI, BASFI, ASDAS) and laboratory (CRP) data was collected from the medical records at baseline and at 4-6thweeks.Statistical analyses were conducted using SPSS version 25. Continuous variables were described with mean/median ± standard deviation (SD).SIJs injection was performed, under ultrasound guidance, using standard procedures with 2mL of lidocaine 1% and 40mg of methylprednisolone, with a 22-gauge needle. The procedure was performed by the same operator. Written informed consents were obtained from all patients.Results:We performed eleven sacroiliac injection in eleven consecutive patients (one procedure per patient). Nine patients (81.8%) were female, mean age (±SD) of 40.6(±9.4) years, median disease duration(±SD) of 0.9(±6.2) years and median BMI(±SD) of 24.2(±3.3). Eight patients (72.7%) had Nr-axSpA. All patients were non-responders to NSAIDs.At 4-6thweeks there was a decreased in median (±SD) BASDAI (5.4±1.9 vs 4.1±1.9), BASFI (4.2±1.4 vs 3.5±2.3) and ASDAS (3.2±0.8 vs 2.2±0.6) indexes.Conclusion:As previous studies demonstrated, this technique seems to be safe and quite effective.Our goal is to increase the number of patients undergoing this technique and have a longer follow up to evaluate its efficacy. The study has several limitations: the mid- and long-term effects should be evaluated in the future based on the results of the short-term effects and the study was not conducted as a double-blinded, controlled study.References:[1]van der Heijde D, Burgos-Vargas R, Ramiro S.,et al. ASAS/EULAR recommendations for the management of ankylosing spondylitis. Ann Rheum Dis 2017; 76:978–991[2]Maugars Y, Mathis C, Vilon P, Prost A. Corticosteroid injection of the sacroiliac joint in patients with seronegative spondylarthropathy. Arthritis Rheum 1992; 35:564–8.[3]Pekkafahli MZ, Kiralp MZ, Basekim CC et al. Sacroiliac joint injections performed with sonographic guidance. J Ultrasound Med 2003;22:553–9[4]Klauser A, De Zordo T, Feuchtner G et al. Feasibility of ultrasound-guided sacroiliac joint injection considering sonoanatomic landmarks at two different levels in cadavers and patients. Arthritis Rheum 2008; 59:1618–1624.Disclosure of Interests:Ana Rita Cunha: None declared, Carolina Mazeda: None declared, Renata Aguiar: None declared, Anabela Barcelos Speakers bureau: Bene, Eli-Lilly, Pfizer, MSD, Novartis


2017 ◽  
Vol 01 (01) ◽  
pp. 020-022
Author(s):  
Praveen Vasanthraj ◽  
Varun Bandi ◽  
Venkata Sai ◽  
Manikanthan Shekar

AbstractChronic renal diseases have been on rise with most patients requiring renal transplantation. With advances in treatment, patients undergo hemodialysis through arteriovenous (AV) fistulas and grafts. Thrombosis in these fistulas and grafts are more common and may result in failure. Interventional radiology plays an important role in managing these thromboses through catheter-directed thrombolysis. With success rate of more than 80%, catheter-directed thrombolysis has become the treatment of choice. However, the need of trained personnel, well-equipped catheter laboratories, and expensiveness are its disadvantages. We share our initial experience in two patients in whom we have performed ultrasound-guided percutaneous pulse-spray pharmacomechanical thrombolysis as a day-care procedure. This technique is less expensive, can have a wider outreach, and patients can be benefitted early to avoid new access.


2009 ◽  
Vol 37 (7) ◽  
pp. 1394-1399 ◽  
Author(s):  
Theodore F. Schlegel ◽  
Brandon D. Bushnell ◽  
Jenna Godfrey ◽  
Martin Boublik

2005 ◽  
Vol 119 (8) ◽  
pp. 627-628 ◽  
Author(s):  
J A Bryant ◽  
N J Siddiqi ◽  
E J Loveday ◽  
G H Irvine

This case illustrates the surgical use of wire localization, a well tried technique from a different field of surgery, in the removal of an ultrasound-detected, impalpable deep lower cervical lymph node in a high-risk patient. A localization needle with an echogenic tip was placed freehand under ultrasound guidance, immediately before surgery. The imaging and marking of the impalpable cervical lymph node resulted in a precise surgical dissection and a reduction in operating time whilst minimizing risks to the patient and staff.


2018 ◽  
Vol 19 (6) ◽  
pp. 609-614 ◽  
Author(s):  
Soshi Nakamuta ◽  
Toshihiro Nishizawa ◽  
Shiori Matsuhashi ◽  
Arata Shimizu ◽  
Toshio Uraoka ◽  
...  

Background and aim: Malposition of peripherally inserted central catheters placed at the bedside is a well-recognized phenomenon. We report the success rate of the placement of peripherally inserted central catheters with ultrasound guidance for tip positioning and describe the knacks and pitfalls. Materials and methods: We retrospectively reviewed the medical case charts of 954 patients who received peripherally inserted central catheter procedure. Patient clinical data included success rate of puncture, detection rate of tip malposition with ultrasonography, adjustment rate after X-ray, and success rate of peripherally inserted central catheter placement. Results: The success rate of puncture was 100% (954/954). Detection rate of tip malposition with ultrasonography was 82.1% (78/95). The success rate of ultrasound-guided tip navigation was 98.2% (937/954). The success rate of ultrasound-guided tip location was 98.0% (935/954). Adjustment rate after X-ray was 1.79% (17/952). The final success rate of peripherally inserted central catheter placement was 99.8% (952/954). Conclusion: Ultrasound guidance for puncturing and tip positioning is a promising option for the placement of peripherally inserted central catheters. Ultrasound guidance could dispense with radiation exposure and the transfer of patients to the X-ray department.


2019 ◽  
Vol 23 (03) ◽  
pp. e58-e67 ◽  
Author(s):  
Georgina Allen ◽  
Marina Obradov ◽  
Vito Chianca ◽  
Carmelo Messina ◽  
Luca Maria Sconfienza

AbstractPain around the hip and pelvis is a very common condition. Pain may be generated within the joint space (i.e. the hip joint itself, the sacroiliac joints or the pubic symphysis) or from surrounding myotendinous, bursal, or nerve structures. Over the years, percutaneous musculoskeletal procedures have become increasingly popular to diagnose and treat painful conditions around the hip and the pelvis. Most intra- and extra-articular procedures are performed under ultrasound guidance. This article reviews the most common diagnostic and therapeutic procedures that can be performed around the hip and the pelvis under ultrasound guidance.


2020 ◽  
Vol 45 (11) ◽  
pp. 853-859
Author(s):  
Artid Samerchua ◽  
Prangmalee Leurcharusmee ◽  
Krit Panjasawatwong ◽  
Kittitorn Pansuan ◽  
Pasuk Mahakkanukrauh

Background and objectivesThe intercostobrachial nerve (ICBN) has significant anatomical variation. Localization of the ICBN requires an operator’s skill. This cadaveric study aims to describe two simple ultrasound-guided plane blocks of the ICBN when it emerges at the chest wall (proximal approach) and passes through the axillary fossa (distal approach).MethodsThe anatomical relation of the ICBN and adjacent structures was investigated in six fresh cadavers. Thereafter, we described two potential techniques of the ICBN block. The proximal approach was an injection medial to the medial border of the serratus anterior muscle at the inferior border of the second rib. The distal approach was an injection on the surface of the latissimus dorsi muscle at 3–4 cm caudal to the axillary artery. The ultrasound-guided proximal and distal ICBN blocks were performed in seven hemithoraxes and axillary fossae. We recorded dye staining on the ICBN, its branches and clinically correlated structures.ResultsAll ICBNs originated from the second intercostal nerve and 34.6% received a contribution from the first or third intercostal nerve. All ICBNs gave off axillary branches in the axillary fossa and ran towards the posteromedial aspect of the arm. Following the proximal ICBN block, dye stained on 90% of all ICBN’s origins. After the distal ICBN block, all terminal branches and 43% of the axillary branches of the ICBN were stained.ConclusionsThe proximal and distal ICBN blocks, using easily recognized sonoanatomical landmarks, provided consistent dye spread to the ICBN. We encourage further validation of these two techniques in clinical studies.


Sign in / Sign up