scholarly journals Advances in Hemodynamic Analysis in Cardiovascular Diseases Investigation of Energetic Characteristics of Adult and Pediatric Sputnik Left Ventricular Assist Devices during Mock Circulation Support

2019 ◽  
Vol 2019 ◽  
pp. 1-15 ◽  
Author(s):  
Alexander A. Pugovkin ◽  
Aleksandr G. Markov ◽  
Sergey V. Selishchev ◽  
Leonie Korn ◽  
Marian Walter ◽  
...  

The need to simulate the operating conditions of the human body is a key factor in every study and engineering process of a bioengineering device developed for implantation. In the present paper, we describe in detail the interaction between the left ventricle (LV) and our Sputnik left ventricular assist devices (LVADs). This research aims to evaluate the influence of different rotary blood pumps (RBPs) on the LV depending on the degree of heart failure (HF), in order to investigate energetic characteristics of the LV-LVAD interaction and to estimate main parameters of left ventricular unloading. We investigate energetic characteristics of adult Sputnik 1 and Sputnik 2 LVADs connected to a hybrid adult mock circulation (HAMC) and also for the Sputnik pediatric rotary blood pump (PRBP) connected to a pediatric mock circulation (PMC). A major improvement of the LV unloading is observed during all simulations for each particular heart failure state when connected to the LVAD, with sequential pump speed increased within 5000–10000 rpm for adult LVADs and 6000–13000 rpm for PRBP with 200 rpm step. Additionally, it was found that depending on the degree of heart failure, LVADs influence the LV in different ways and a significant support level cannot be achieved without the aortic valve closure. Furthermore, this study expands the information on LV-LVAD interaction, which leads to the optimization of the RBP speed rate control in clinics for adult and pediatric patients suffering from heart failure. Finally, we show that the implementation of control algorithms using the modulation of the RBP speed in order to open the aortic valve and unload the LV more efficiently is necessary and will be content of further research.

2020 ◽  
Vol 8 (9) ◽  
pp. 770-779
Author(s):  
Jadry Gruen ◽  
Cesar Caraballo ◽  
P. Elliott Miller ◽  
Megan McCullough ◽  
Catherine Mezzacappa ◽  
...  

2019 ◽  
Vol 2019 ◽  
pp. 1-18 ◽  
Author(s):  
Jeongeun Son ◽  
Dongping Du ◽  
Yuncheng Du

Left ventricular assist devices (LVADs) have been used for end-stage heart failure patients as a therapeutic option. The aortic valve plays a critical role in heart failure and its treatment with a LVAD. The cardiovascular-LVAD model is often used to investigate the physiological demands required by patients and predict the hemodynamic of the native heart supported with a LVAD. As it is a “bridge-to-recovery” treatment, it is important to maintain appropriate and active dynamics of the aortic valve and the cardiac output of the native heart, which requires that the LVAD pump be adjusted so that a proper balance between the blood contributed through the aortic valve and the pump is maintained. In this paper, we investigate how the pump power of the LVAD pump can affect the dynamic behaviors of the aortic valve for different levels of activity and different severities of heart failure. Our objective is to identify a critical value of the pump power (i.e., breakpoint) to ensure that the LVAD pump does not take over the pumping function in the cardiovascular-pump system and share the ejected blood with the left ventricle to help the heart to recover. In addition, the hemodynamic often involves variability due to patients’ heterogeneity and the stochastic nature of the cardiovascular system. The variability poses significant challenges to understanding dynamic behaviors of the aortic valve and cardiac output. A generalized polynomial chaos (gPC) expansion is used in this work to develop a stochastic cardiovascular-pump model for efficient uncertainty propagation, from which it is possible to rapidly calculate the variance in the aortic valve opening duration and the cardiac output in the presence of variability. The simulation results show that the gPC-based cardiovascular-pump model is a reliable platform that can provide useful information to understand the effect of the LVAD pump on the hemodynamic of the heart.


Mathematics ◽  
2020 ◽  
Vol 8 (8) ◽  
pp. 1331 ◽  
Author(s):  
Sergey Simakov ◽  
Alexander Timofeev ◽  
Timur Gamilov ◽  
Philip Kopylov ◽  
Dmitry Telyshev ◽  
...  

Left ventricular assist devices provide circulatory support to patients with end-stage heart failure. The standard operating conditions of the pump imply limitations on the rotation speed of the rotor. In this work we validate a model for three pumps (Sputnik 1, Sputnik 2, Sputnik D) using a mock circulation facility and known data for the pump HeartMate II. We combine this model with a 1D model of haemodynamics in the aorta and a lumped model of the left heart with valves dynamics. The model without pump is validated with known data in normal conditions. Simulations of left ventricular dilated cardiomyopathy show that none of the pumps are capable of reproducing the normal stroke volume in their operating ranges while complying with all criteria of physiologically feasible operation. We also observe that the paediatric pump Sputnik D can operate in the conditions of adult circulation with the same efficiency as the adult LVADs.


2020 ◽  
pp. 039139882092702
Author(s):  
Hernan G Marcos-Abdala ◽  
Ana S Cruz-Solbes ◽  
Imad Hussain ◽  
Barry Trachtenberg ◽  
Guha Ashrith ◽  
...  

While Doppler and cuff blood pressure techniques are prevalent methods of assessing blood pressure in patients with continuous flow left ventricular assist devices, the impact of pulsatility on measurement is not well established. Retrospective chart analysis of clinical variables including pulse perception, blood pressure (Doppler and standard cuff), and aortic valve opening on echo at clinic visit were abstracted. Stable outpatients on continuous flow left ventricular assist devices support with concomitant portable echo assessment were included. Mean average difference was calculated and Pearson’s correlation performed for all those patients who had both Doppler and cuff pressure obtained. In all, 74 Heartmate-II patients with a median time from implant of 380 days were analyzed. A pulse was perceived in 82% of patients with persistent aortic valve opening on portable echo and also in 30% of those who had a persistently closed aortic valve. The mean average difference between the Doppler and systolic cuff pressure was ~13 mmHg ( r = 0.5, p = 0.004) when a pulse was present and ~11 mmHg when aortic valve was open ( r = 0.68, p < 0.0001). Pulse presence seems to reflect aortic valve opening a majority of the time but not always. In the presence of a prominent pulse or persistent aortic valve opening, the Doppler pressure seems to be more reflective of a systolic pressure than mean perfusion pressure. Hence, assessment of pulsatility needs to be incorporated into blood pressure measurement methods for patients with continuous flow left ventricular assist devices.


Sign in / Sign up

Export Citation Format

Share Document