scholarly journals Store Separation: Photogrammetric Solution for the Static Ejection Test

2019 ◽  
Vol 2019 ◽  
pp. 1-18
Author(s):  
Luiz Eduardo Guarino de Vasconcelos ◽  
Nelson Paiva Oliveira Leite ◽  
André Yoshimi Kusumoto ◽  
Leandro Roberto ◽  
Cristina Moniz Araujo Lopes

The process of developing and certifying aircraft and aeronautical systems requires the execution of experimental flight test campaigns to determine the actual characteristics of the system being developed and/or validated. In this process, there are many campaigns that are inherently dangerous, such as the store separation. In this particular case, the greatest risk is the collision of the store with the fuselage of the aircraft. To mitigate the risks of this campaign, it is necessary to compare the actual trajectory of a separation with its simulated estimates. With such information, it is possible to decide whether the next store release can be done with the required safety and/or whether the model used to estimate the separation trajectory is valid or not. Consequently, exact determination of the trajectory of the separation is necessary. Store separation is a strategic, relevant, and complex process for all nations. The two main techniques for determining the quantitative store trajectory data with 6DoF (six degrees of freedom) are photogrammetry and instrumented telemetry packages (data obtained from inertial sensors that are installed in the store). Each presents advantages and disadvantages. In regard to photogrammetry, several market solutions can be used to perform these tests. However, the result of the separation trajectory is only obtained after the test flight, and therefore, it is not possible to safely carry out more than one on the same flight. In this context, the development and validation of a solution that will allow the realization of near real-time separation analysis are in fact an innovative and original work. This paper discusses the development and validation, through actual static ejection tests, of the components that will compose a new onboard optical trajectory system for use in store separation campaigns. This solution includes the implementation of a three-dimensional (3D) calibration field that allows calibration of the optical assembly with just one photo per optical assembly, development of a complete analytical model for camera calibration, and development of specific software for identification and tracking of targets in two-dimensional (2D) coordinate images and three-dimensional (3D) coordinate trajectory calculation. In relation to the calibration, the analytical model is based on a pinhole type camera and considers its intrinsic parameters. This allowed for a mean square error smaller than ±3.9 pixels @1σ. The 3D analysis software for 6DoF trajectory expression was developed using photogrammetry techniques and absolute orientation. The uncertainty associated with the position measurement of each of the markers varies from ±0.02 mm to ±8.00 mm @1σ, depending on the geometry of the viewing angles. The experiments were carried out at IPEV (Flight Test Research Institute)/Brazil, and the results were considered satisfactory. We advocate that the knowledge gained through this research contributes to the development of new methods that permit almost real-time analysis in store separation tests.

2021 ◽  
Vol 12 ◽  
Author(s):  
Tae-Soo Noh ◽  
Moo Kyun Park ◽  
Jun Ho Lee ◽  
Seung Ha Oh ◽  
Ji-Hoon Kim ◽  
...  

Objective: We used volumetric three-dimensional (3D) analysis to quantitatively evaluate the extent of endolymphatic hydrops (EH) in the entire inner ear. We tested for correlations between the planimetric and volumetric measurements, to identify their advantages and disadvantages.Methods: HYDROPS2-Mi2 EH images were acquired for 32 ears (16 patients): 16 ipsilateral ears of MD patients (MD-ears) and 16 contralateral ears. Three-T MR unit with a 32-channel phased-array coil/the contrast agent to fill the perilymphatic space and the HYDROPS2-Mi2 sequence. We calculated the EH% [(endolymph)/(endolymph+perilymph)] ratio and analyzed the entire inner ear in terms of the volumetric EH% value, but only single cochlear and vestibular slices were subjected to planimetric EH% evaluation. The EH% values were compared between MD ears and non-MD ears, to evaluate the diagnostic accuracy of the two methods.Results: The volumetric EH% was significantly higher for MD vestibules (50.76 ± 13.78%) than non-MD vestibules (39.50 ± 8.99%). The planimetric EH% was also significantly higher for MD vestibules (61.98 ± 20.65%) than non-MD vestibules (37.22 ± 12.95%). The vestibular and cochlear volumetric EH% values correlated significantly with the planimetric EH% values of the MD ear.Conclusion: Volumetric and planimetric EH measurements facilitate diagnosis of MD ears compared to non-MD ears. Both methods seem to be reliable and consistent; the measurements were significantly correlated in this study. However, the planimetric EH% overestimates the extent of vestibular hydrops by 26.26%. Also, planimetric data may not correlate with volumetric data for non-MD cochleae with normal EH% values.


2019 ◽  
Vol 379 (2) ◽  
pp. 245-254 ◽  
Author(s):  
Takayuki Miyaki ◽  
Yuto Kawasaki ◽  
Yasue Hosoyamada ◽  
Takashi Amari ◽  
Mui Kinoshita ◽  
...  

AbstractPodocytes are specialized epithelial cells used for glomerular filtration in the kidney. They can be divided into the cell body, primary process and foot process. Here, we describe two useful methods for the three-dimensional(3D) visualization of these subcellular compartments in rodent podocytes. The first method, field-emission scanning electron microscopy (FE-SEM) with conductive staining, is used to visualize the luminal surface of numerous podocytes simultaneously. The second method, focused-ion beam SEM (FIB-SEM) tomography, allows the user to obtain serial images from different depths of field, or Z-stacks, of the glomerulus. This allows for the 3D reconstruction of podocyte ultrastructure, which can be viewed from all angles, from a single image set. This is not possible with conventional FE-SEM. The different advantages and disadvantages of FE-SEM and FIB-SEM tomography compensate for the weaknesses of the other. The combination renders a powerful approach for the 3D analysis of podocyte ultrastructure. As a result, we were able to identify a new subcellular compartment of podocytes, “ridge-like prominences” (RLPs).


2017 ◽  
Vol 2017 ◽  
pp. 1-20 ◽  
Author(s):  
Qinghua Huang ◽  
Zhaozheng Zeng

Real-time three-dimensional (3D) ultrasound (US) has attracted much more attention in medical researches because it provides interactive feedback to help clinicians acquire high-quality images as well as timely spatial information of the scanned area and hence is necessary in intraoperative ultrasound examinations. Plenty of publications have been declared to complete the real-time or near real-time visualization of 3D ultrasound using volumetric probes or the routinely used two-dimensional (2D) probes. So far, a review on how to design an interactive system with appropriate processing algorithms remains missing, resulting in the lack of systematic understanding of the relevant technology. In this article, previous and the latest work on designing a real-time or near real-time 3D ultrasound imaging system are reviewed. Specifically, the data acquisition techniques, reconstruction algorithms, volume rendering methods, and clinical applications are presented. Moreover, the advantages and disadvantages of state-of-the-art approaches are discussed in detail.


2010 ◽  
Vol 151 (21) ◽  
pp. 854-863 ◽  
Author(s):  
Attila Nemes ◽  
Marcel L. Geleijnse ◽  
Osama I. I. Soliman ◽  
Wim B. Vletter ◽  
Jackie S. McGhie ◽  
...  

Jelenleg az echokardiográfia a legszéleskörűbben alkalmazott rutin noninvazív diagnosztikus eljárás, amelynek segítségével a mitralis billentyű morfológiája és funkciója jellemezhető. Ennek az összefoglaló jellegű közleménynek a célja az egyik legújabb echokardiográfiás fejlesztés, a transthoracalis real-time háromdimenziós echokardiográfia szerepének bemutatása a mitralis billentyű vizsgálatában.


Sign in / Sign up

Export Citation Format

Share Document