Maternal Blood Volume in Placenta of the Rhesus Monkey Measured in vivo by Positron Emission Tomography

1991 ◽  
Vol 31 (1) ◽  
pp. 1-7 ◽  
Author(s):  
Lars Berglund ◽  
Anders Lilja ◽  
Jesper Andersson ◽  
Bo Lindberg ◽  
Johan Ulin ◽  
...  
1984 ◽  
Vol 4 (3) ◽  
pp. 317-322 ◽  
Author(s):  
Adriaan A. Lammertsma ◽  
David J. Brooks ◽  
Ronald P. Beaney ◽  
David R. Turton ◽  
Malcolm J. Kensett ◽  
...  

A method is described for measuring the regional cerebral-to-large vessel haematocrit ratio using inhalation of carbon-11-labelled carbon monoxide and the intravenous injection of carbon-11-labelled methyl-albumin in combination with positron emission tomography. The mean value in a series of nine subjects was 0.69. This is ∼20% lower than the value of 0.85 previously reported. It is concluded that previous measurements of regional cerebral blood volume using a haematocrit ratio of 0.85 will have underestimated the value of regional cerebral blood volume by 20%.


1994 ◽  
Vol 663 (2) ◽  
pp. 191-198 ◽  
Author(s):  
Hirotaka Onoe ◽  
Osamu Inoue ◽  
Kazutoshi Suzuki ◽  
Hideo Tsukada ◽  
Takashi Itoh ◽  
...  

2019 ◽  
Vol 6 (1) ◽  
Author(s):  
Carlos Velasco ◽  
Adriana Mota-Cobián ◽  
Jesús Mateo ◽  
Samuel España

Abstract Background Multi-tracer positron emission tomography (PET) imaging can be accomplished by applying multi-tracer compartment modeling. Recently, a method has been proposed in which the arterial input functions (AIFs) of the multi-tracer PET scan are explicitly derived. For that purpose, a gamma spectroscopic analysis is performed on blood samples manually withdrawn from the patient when at least one of the co-injected tracers is based on a non-pure positron emitter. Alternatively, these blood samples required for the spectroscopic analysis may be obtained and analyzed on site by an automated detection device, thus minimizing analysis time and radiation exposure of the operating personnel. In this work, a new automated blood sample detector based on silicon photomultipliers (SiPMs) for single- and multi-tracer PET imaging is presented, characterized, and tested in vitro and in vivo. Results The detector presented in this work stores and analyzes on-the-fly single and coincidence detected events. A sensitivity of 22.6 cps/(kBq/mL) and 1.7 cps/(kBq/mL) was obtained for single and coincidence events respectively. An energy resolution of 35% full-width-half-maximum (FWHM) at 511 keV and a minimum detectable activity of 0.30 ± 0.08 kBq/mL in single mode were obtained. The in vivo AIFs obtained with the detector show an excellent Pearson’s correlation (r = 0.996, p < 0.0001) with the ones obtained from well counter analysis of discrete blood samples. Moreover, in vitro experiments demonstrate the capability of the detector to apply the gamma spectroscopic analysis on a mixture of 68Ga and 18F and separate the individual signal emitted from each one. Conclusions Characterization and in vivo evaluation under realistic experimental conditions showed that the detector proposed in this work offers excellent sensibility and stability. The device also showed to successfully separate individual signals emitted from a mixture of radioisotopes. Therefore, the blood sample detector presented in this study allows fully automatic AIFs measurements during single- and multi-tracer PET studies.


Sign in / Sign up

Export Citation Format

Share Document