scholarly journals Comparison of swept-source versus spectral-domain optical coherence tomography angiography for detection of macular neovascularization

Author(s):  
Anna Lentzsch ◽  
Laura Schöllhorn ◽  
Christel Schnorr ◽  
Robert Siggel ◽  
Sandra Liakopoulos

Abstract Purpose To compare swept-source (SS) versus spectral-domain (SD) optical coherence tomography angiography (OCTA) for the detection of macular neovascularization (MNV). Methods In this prospective cohort study, 72 eyes of 54 patients with subretinal hyperreflective material (SHRM) and/or pigment epithelial detachment (PED) on OCT possibly corresponding to MNV in at least one eye were included. OCTA scans were acquired using two devices, the PLEX Elite 9000 SS-OCTA and the Spectralis SD-OCTA. Fluorescein angiography (FA) was used as reference. Two graders independently evaluated en face OCTA images using a preset slab as well as a manually modified slab, followed by a combination of en face and cross-sectional OCTA. Results Sensitivity (specificity) for the automated slabs was 51.7% (93.0%) for SS-OCTA versus 58.6% (95.3%) for SD-OCTA. Manual modification of segmentation increased sensitivity to 79.3% for SS-OCTA but not for SD-OCTA (58.6%). The combination of en face OCTA with cross-sectional OCTA reached highest sensitivity values (SS-OCTA: 82.8%, SD-OCTA: 86.2%), and lowest number of cases with discrepancies between SS-OCTA and SD-OCTA (4.2%). Fleiss kappa as measure of concordance between FA, SS-OCTA, and SD-OCTA was 0.56 for the automated slabs, 0.60 for the manual slabs, and 0.73 (good agreement) for the combination of en face OCTA with cross-sectional OCTA. Concordance to FA was moderate for the automated slabs and good for manual slabs and combination with cross-sectional OCTA of both devices. Conclusion Both devices reached comparable results regarding the detection of MNV on OCTA. Sensitivity for MNV detection and agreement between devices was best when evaluating a combination of en face and cross-sectional OCTA.

Eye ◽  
2022 ◽  
Author(s):  
Robert Siggel ◽  
Christel Spital ◽  
Anna Lentzsch ◽  
Sandra Liakopoulos

Abstract Purpose To evaluate sensitivity and specificity of swept source-optical coherence tomography angiography (SS-OCTA) en face images versus cross-sectional OCTA versus a combination of both for the detection of macular neovascularization (MNV). Design Prospective cohort study. Participants Consecutive patients with various chorioretinal diseases and subretinal hyperreflective material (SHRM) and/or pigment epithelial detachment (PED) on OCT possibly corresponding to MNV in at least one eye. Methods 102 eyes of 63 patients with fluorescein angiography (FA), OCT and SS-OCTA performed on the same day were included. FA images, the outer retina to choriocapillaris (ORCC) OCTA en face slab, a manually modified en face slab (‘custom slab’), cross-sectional OCTA and a combination of OCTA en face and cross-section were evaluated for presence of MNV. Main outcome measures Sensitivity and specificity for MNV detection, as well as the concordance was calculated using FA as the reference. Results OCTA en face imaging alone yielded a sensitivity of 46.3% (automated)/78.1% (custom) and specificity of 93.4% (automated)/88.5% (custom) for MNV detection. Cross-sectional OCTA (combination with en face) resulted in a sensitivity of 85.4% (82.9%) and specificity of 82.0% (85.3%). Concordance to FA was moderate for automated en face OCTA (κ = 0.43), and substantial for custom en face OCTA (κ = 0.67), cross-sectional OCTA (κ = 0.66) and the combination (κ = 0.68). Conclusion Segmentation errors result in decreased sensitivity for MNV detection on automatically generated OCTA en face images. Cross-sectional OCTA allows detection of MNV without manual modification of segmentation lines and should be used for evaluation of MNV on OCTA.


2021 ◽  
Author(s):  
Raphael Lejoyeux ◽  
Raphael Atia ◽  
Kiran Vupparaboina ◽  
Mohamed Ibrahim ◽  
Jose-Alain Sahel ◽  
...  

Abstract Purpose: To study the topographic distribution of the short posterior ciliary arteries (SPCA) entry sites into the choroid in normal eyes using structural en-face swept source optical coherence tomography (SS-OCT). Methods: Retrospective analysis of SS-OCT scans (wide-field structural SS-OCT 12x12mm) of 13 healthy subjects was performed. Cross-sectional swept-source OCT scans derived from a volume scan were represented as en-face image display following the Choroid-Scleral Interface to obtain en-face OCT. SPCAs in their last scleral location before choroidal entrance were identified manually, counted and localized by two masked observers. Correlations between two masked observers were analyzed using inter- and intra- class correlation. Results: Accuracy for the choroidal inner and outer border segmentation was 95-99%. Eighteen eyes from 13 normal subjects were included for SPCA analysis. The mean number of arteries was 13.8±3.5 per eye. Thirty-six percent were in the center of the posterior pole image; however, 21% were in the temporal part of the posterior pole. Median accuracy of the detection is 0.94. The correlation between the two observers was fair (0.54).Conclusion: Our algorithm allows visualization of the SPCA at the posterior pole of the eye using wide-field en-face SS-OCT. It can also help the clinicians to study the SPCAs in numerous ocular diseases, particularly its relationship with focal choroidal diseases.


2020 ◽  
Vol 20 (1) ◽  
Author(s):  
A. R. Kee ◽  
V. C. H. Yip ◽  
E. L. T. Tay ◽  
C. W. Lim ◽  
J. Cheng ◽  
...  

Abstract Background To understand the differences between two different optical coherence tomography angiography (OCTA) devices in detecting glaucomatous from healthy eyes by comparing their vascular parameters, diagnostic accuracy and test-retest reliability. Methods A cross-sectional observational study was performed on healthy and glaucoma subjects, on whom two sets of OCTA images of optic disc and macula were acquired using both AngioVue (Optovue, USA) and Swept Source (Topcon, Japan) OCTA devices during one visit. A novel in-house software was used to calculate the vessel densities. Diagnostic accuracy of the machines in differentiating healthy versus glaucomatous eyes was determined using area under the receiver operating characteristic curve (AUROC) and test-retest repeatability of the machines was also evaluated. Results A total of 80 healthy and 38 glaucomatous eyes were evaluated. Glaucomatous eyes had reduced mean vessel density compared to healthy controls in all segmented layers of the optic disc and macula using AngioVue (p ≤ 0.001). However, glaucomatous eyes had higher mean vessel density on optic disc scans using Swept Source, with lack of statistically significant difference between healthy and glaucomatous eyes. The AUROC showed better diagnostic accuracy of AngioVue (0.761–1.000) compared to Swept Source (0.113–0.644). The test-retest reliability indices were generally better using AngioVue than Swept Source. Conclusions AngioVue showed better diagnostic capability and test-retest reliability compared to Swept Source. Further studies need to be undertaken to evaluate if there is any significant difference between the various machines in diagnosing and monitoring glaucoma.


PLoS ONE ◽  
2020 ◽  
Vol 15 (12) ◽  
pp. e0243830
Author(s):  
Yining Dai ◽  
Hao Zhou ◽  
Qinqin Zhang ◽  
Zhongdi Chu ◽  
Lisa C. Olmos de Koo ◽  
...  

Purpose To quantitatively assess choriocapillaris (CC) flow deficits in eyes with diabetic retinopathy (DR) using swept-source optical coherence tomography angiography (SS-OCTA). Methods Diabetic subjects with different stages of DR and age-matched healthy subjects were recruited and imaged with SS-OCTA. The en face CC blood flow images were generated using previously published and validated algorithms. The percentage of CC flow deficits (FD%) and the mean CC flow deficit size were calculated in a 5-mm-diameter circle centered on the fovea from the 6×6-mm scans. Results Forty-five diabetic subjects and 27 control subjects were included in the study. The CC FD% in diabetic eyes was on average 1.4-fold greater than in control eyes (12.34±4.14% vs 8.82±2.61%, P < 0.001). The mean CC FD size in diabetic eyes was on average 1.4-fold larger than in control eyes (2151.3± 650.8μm2 vs 1574.4±255.0 μm2, P < 0.001). No significant difference in CC FD% or mean CC FD size was observed between eyes with nonproliferative DR and eyes with proliferative DR (P = 1.000 and P = 1.000, respectively). Conclusions CC perfusion in DR can be objectively and quantitatively assessed with FD% and FD size. In the macular region, both CC FD% and CC FD size are increased in eyes with DR. SS-OCTA provides new insights for the investigations of CC perfusion status in diabetes in vivo.


Sign in / Sign up

Export Citation Format

Share Document