scholarly journals Advanced control strategy of DFIG during symmetrical grid fault

Author(s):  
Tariq Riouch ◽  
Cristian Nichita

<p>This article proposes a novel scheme to improve the doubly-fed induction generator (DFIG) behavior during grid fault. The DFIG’s are sensitives to voltage variations when abrupt variations of the wind velocity arrive. For enhancing DFIG behavior, protecting the converters, and smoothing the fluctuations power output of the DFIG under sag voltage; a novel hybrid energy storage system scheme and its controller are proposed. The main advantages of our approach are a faster response and suppressing overvoltage on DC bus and globally less stress in the storage system. The control structure decreases the tiredness on the battery and restores the DC bus voltage rapidly, globally the battery system operating time increases. The results obtained by simulations in MATLAB validate the benefits of the suggested control.</p>

2014 ◽  
Vol 953-954 ◽  
pp. 765-770
Author(s):  
Yang Yang Wu ◽  
You Kuan Liu ◽  
Pei Tian

Due to the large number of distributed power supply random connected to power grid, it has severely influenced on power quality of the grid. In the storage battery directly on the basis of the DC bus, adopting the method of hybrid energy storage system makes a research on the output characteristics of photovoltaic array and the charging and discharging of battery and super capacitor. Research results show that the hybrid energy storage system can take advantage of the DC/DC converter to coordinate photovoltaic array, energy storage unit and the energy flows among load, also that the stability of DC bus voltage can be ensured by the system switch from the different work patterns.


2021 ◽  
Vol 2108 (1) ◽  
pp. 012091
Author(s):  
Congzhen Xie ◽  
Jigang Wang ◽  
Bing Luo ◽  
Xiaolin Li ◽  
Lei Ja

Abstract In DC microgrid (MG), the hybrid energy storage system (HESS) of battery and supercapacitor (SC) has the important function of buffering power impact, which comes from renewable energy sources (RES) and loads. This paper proposes a HESS control strategy with DC bus voltage self-recovery function. High and low frequency power decomposition based on virtual droop control, and DC bus drop voltage is compensated by added proportional integral regulation. The relationship between DC bus voltage recovery and super-capacitor (SC) state of charge (SoC) recovery is analyzed. The system can realize stable energy storage, supply under frequent load power impact. The effectiveness of the proposed control strategy is verified by simulation in MATLAB/Simulink.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2854 ◽  
Author(s):  
Danijel Pavković ◽  
Mihael Cipek ◽  
Zdenko Kljaić ◽  
Tomislav Mlinarić ◽  
Mario Hrgetić ◽  
...  

This contribution outlines the design of electric vehicle direct-current (DC) bus control system supplied by a battery/ultracapacitor hybrid energy storage system, and its coordination with the fully electrified vehicle driveline control system. The control strategy features an upper-level DC bus voltage feedback controller and a direct load compensator for stiff tracking of variable (speed-dependent) voltage target. The inner control level, comprising dedicated battery and ultracapacitor current controllers, is commanded by an intermediate-level control scheme which dynamically distributes the upper-level current command between the ultracapacitor and the battery energy storage systems. The feedback control system is designed and analytical expressions for feedback controller parameters are obtained by using the damping optimum criterion. The proposed methodology is verified by means of simulations and experimentally for different realistic operating regimes, including electric vehicle DC bus load step change, hybrid energy storage system charging/discharging, and electric vehicle driveline subject to New European Driving Cycle (NEDC), Urban Driving Dynamometer Schedule (UDDS), New York Certification Cycle (NYCC) and California Unified Cycle (LA92), as well as for abrupt acceleration/deceleration regimes.


2020 ◽  
Vol 19 (3) ◽  
pp. 117-129
Author(s):  
Carlos Andrés Ramos-Paja ◽  
Juan David Bastidas-Rodríguez ◽  
Daniel González-Montoya

This paper proposes a non-linear control structure for a hybrid energy storage system with a series architecture, which regulates the voltage of a DC bus (output voltage) and ensures that the battery current fulfills the current slew-rate restriction. The proposed solution has two stages, in the first one, the battery is connected to a buck/boost converter that feeds an auxiliary capacitor. In the second stage, the auxiliary capacitor is connected to a DC bus through a second buck/boost converter. Both converters are regulated using cascaded control systems, where the inner loops are slidingmode controllers of the inductors’ current, and the outer loops in the first and second converter are designed to limit the slew-rate of the battery current and to regulate the dc bus voltage, respectively. The paper provides the design procedure for the controllers and validates its performance with simulation results for the power system operating in charging, discharging and stand-by modes.


2021 ◽  
Vol 261 ◽  
pp. 01019
Author(s):  
Feiyue Feng ◽  
Changchun Chi

In order to suppress the busbar voltage fluctuations in the DC microgrid, this paper establishes an optical storage DC microgrid system with a hybrid energy storage system to achieve the purpose of stabilizing the DC bus voltage. This system focuses on the component hybrid energy storage unit, and uses the structure of three batteries and supercapacitors (SC) in parallel to improve the stability of the system, while ensuring the frequency division distribution between devices.


Sign in / Sign up

Export Citation Format

Share Document