Abstract 4858: Patterns in Beta Blockerw use ith Cardiac Resynchronization Therapy: Insights from the COMPANION Study

Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Frank McGrew ◽  
John Boehmer ◽  
Alan Bank ◽  
Elizabeth Galle ◽  
Patrick Yong ◽  
...  

Cardiac resynchronization therapy (CRT) is typically delivered in addition to background heart failure medications that include beta blockers (BB). Since CRT devices also provide rate support, it was hypothesized that CRT may influence BB use post-implant. We sought to compare BB use in the treatment arms of the COMPANION study, which randomized patients (pts) to optimal pharmacological therapy (OPT) alone or in combination with CRT with or without a defibrillator. The database was analyzed retrospectively for a 12-month period post-randomization. BB dosages were evaluated at the 12-month visit with the last follow-up (FU) visit used for those without 12 month FU data. Pts with no FU data were excluded. Dosages are expressed in carvedilol equivalents. The median dose between the two treatment arms were compared as well as up/down titration rates. Of 1520 pts randomized, 1376 (91%) were followed for at least three months and 689 (50%) were followed for at least 12 months. The median dose was 25 mg/day for both groups at baseline (p=0.93) and again at 12 months (p=0.53). BB use between arms is characterized in the tables below: In this retrospective analysis of the COMPANION trial, there was no significant association between treatment arm and BB drug use. Up/down-titration rates and median dosages were virtually identical between the two arms. COMPANION did not require investigators to increase BB dosage; accordingly, a prospective study would be needed to definitively determine if BB dosage can be titrated more aggressively with CRT.

2017 ◽  
Vol 40 (11) ◽  
pp. 1279-1285
Author(s):  
Bharatraj Banavalikar ◽  
Anees Thajudeen ◽  
Narayanan Namboodiri ◽  
Krishna Kumar Mohanan Nair ◽  
Abhilash Srivilasam Pushpangadhan ◽  
...  

Author(s):  
Mitsuo Sobajima ◽  
Nobuyuki Fukuda ◽  
Hiroshi Ueno ◽  
Koichiro Kinugawa

Abstract Background  The safety and efficacy of MitraClip for advanced heart failure (HF) patients who are inotrope-dependent or mechanically supported are unknown. Case summary  The patient was a 71-year-old man diagnosed as dilated cardiomyopathy in 2003. He was admitted due to worsening HF in January 2019 and became dependent upon intravenous infusion of inotropes. During the 8-month hospitalization, his haemodynamics were relatively static with bed rest and continuous inotropes, but he was definitely dependent on them. Our multidisciplinary team decided to perform both cardiac resynchronization therapy (CRT) and MitraClip under Impella support. First, Impella was inserted from left subclavian artery. After a week, CRT was implanted from right subclavian vein, and the QRS duration of electrocardiogram became remarkably narrow. MitraClip was performed 2 weeks after Impella, and functional mitral regurgitation improved from severe to mild, and Impella was removed on the same day. Inotropes could be ceased, and he was discharged 2 months after MitraClip. Discussion  During inotrope-dependent status, there was a risk that HF would worsen with haemodynamic collapse when performing CRT implantation, and we firstly supported his haemodynamics by Impella. Cardiac resynchronization therapy implantation before MitraClip seemed to be crucial. In fact, the mitral valve morphology before Impella insertion had very poor coaptation of the anterior and posterior leaflets that was not optimal for MitraClip procedure. But the Impella support and correction of dyssynchrony by CRT markedly improved the coaptation of those leaflets. The combination therapy of CRT and MitraClip unloading with Impella maybe a new therapeutic option for advanced HF.


Circulation ◽  
2007 ◽  
Vol 116 (suppl_16) ◽  
Author(s):  
Andrea M Thelen ◽  
Christopher L Kaufman ◽  
Kevin V Burns ◽  
Daniel R Kaiser ◽  
Aaron S Kelly ◽  
...  

Background: Previous large studies on the effects of cardiac resynchronization therapy (CRT) in patients with heart failure have generally excluded patients previously paced from the right ventricle (RV). Previously RV paced patients (RVp) can exhibit an iatrogenic cause of dyssynchrony and reduced systolic function and thus, may respond differently to CRT than patients not previously RV paced (nRVp). The purpose of this study was to test the hypothesis that RVp patients have greater improvements in left ventricular systolic function, volumes, and dyssynchrony in response to CRT than nRVp. Methods: Standard echocardiograms with tissue Doppler imaging were performed before and after chronic CRT in RVp (n = 21, 16 male) and nRVp (n = 70, 54 male) heart failure patients. Ejection fraction (EF), left ventricular end diastolic (LVEDV) and systolic (LVESV) volumes were calculated using the biplane Simpson’s method. Longitudinal dyssynchrony was calculated as the standard deviation of time to peak displacement (TT-12) of 12 segments in the apical views. Using mid-ventricular short axis views and speckle-tracking methods, radial dyssynchrony (Rad dys ) was calculated as the maximal time difference between six myocardial segments for peak radial strain. Echo response was defined as ≥ 15% reduction in LVESV. Results are reported as mean ± SD. Results: Significant baseline differences (p < 0.05) were observed between groups (RVp vs. nRVp) for age (74 ± 13 vs. 67 ± 13 year), follow-up time (6.1 ± 1.8 vs. 4.6 ± 2.1 months), LVEDV (154.3±50.8 vs.185.3±56.9 mL), and a trend for LVESV (112.4 ± 40.6 vs. 134.9 ± 47 mL, p = 0 .05). No differences were observed for EF, etiology of heart failure, and dyssynchrony measures between groups at baseline. Echo response rate was significantly ( p < 0.05) greater in RVp (76%) than nRVp (57%). After adjusting for baseline differences, RVp had greater improvement in EF (14 ± 9 vs. 8 ± 7%, p < 0.05) and LVESV (−33 ± 18 vs. −20 ± 21%, p < 0.05). After adjustment for follow-up time, no difference was observed for change in dyssynchrony between groups. Conclusion: RVp patients upgraded to CRT exhibit greater improvements in systolic function and ventricular remodeling as compared to nRVp patients.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
S Briongos Figuero ◽  
A Estevez ◽  
M L Perez ◽  
J B Martinez-Ferrer ◽  
L Alvarez-Costa ◽  
...  

Abstract Background Adaptive cardiac resynchronization therapy (aCRT) algorithm provides synchronized left ventricular (LV) only pacing and ambulatory optimization of the intrinsic atrioventricular and interventricular conduction intervals. Studies reporting morbidity and mortality outcomes of aCRT carriers in daily clinical practice are lacking. Purpose To determine in a real-life setting, whether 1-year outcomes were different among CRT carriers undergoing aCRT pacing and those under conventional biventricular (biV) pacing. Methods Symptomatic heart failure (HF) patients with sinus rhythm undergoing first CRT-defibrillator implant were selected from the UMBRELLA nationwide registry (2012–2017). The primary endpoint was the composite of all-cause mortality or HF hospitalization at 12-month follow-up. HF admission was defined as hospitalization due to symptoms requiring intravenous diuretic treatment. Primary healthcare records were used to prospectively collect all data. Results Two hundred and six patients were collected (66.1±8.7 years; 73.3% male). Eighty-seven out of 206 patients were implanted with an aCRT capable device, but this algorithm was activated at implant and remained enabled at 1-year in 59 patients (aCRT group). The other 147 patients composed the non-aCRT group. At implant left bundle branch block was present in 93% of patients, 69.6% of population was in functional class III or IV and mean left ventricle ejection fraction was of 26.5±5.6%. Non-ischemic cardiomyopathy was present in 63.1% of patients and optimal medical treatment was achieved in majority of population (92% of patients with beta-blockers; angiotensin-converting enzyme inhibitorsor angiotensin II receptor blockersin 89%). The percentage of ventricular pacing through 12 months was 96.1±9.4% in non-aCRT patients and 97.5±2.7% in aCRT patients (p=0.261). In aCRT patients, LV-only pacing accounted for a mean of 53.3±37.6% of all ventricular pacing. After 12-month follow-up period, 25 patients (12.1%) met the primary composite endpoint of death or HF hospitalization. Nine patients died and nineteen patients were admitted due to worsening HF. There was no difference in the risk of all-cause death or HF hospitalization between aCRT and non-aCRT patients (10.2% vs. 12.9% respectively; OR=0.76, CI: 0.29–2.01, p=0.585) Conclusions In this contemporary cohort of HF patients undergoing CRT with high percentages of ventricular pacing, clinical performance of aCRT algorithm was adequate. The risk of death or HF hospitalization was low and no differences were observed at one-year follow-up. Future randomized studies will clarify the role of this algorithm in CRT carriers. Acknowledgement/Funding None


2019 ◽  
Vol 41 (21) ◽  
pp. 1976-1986 ◽  
Author(s):  
Sérgio Barra ◽  
Rui Providência ◽  
Kumar Narayanan ◽  
Serge Boveda ◽  
Rudolf Duehmke ◽  
...  

Abstract Aims While data from randomized trials suggest a declining incidence of sudden cardiac death (SCD) among heart failure patients, the extent to which such a trend is present among patients with cardiac resynchronization therapy (CRT) has not been evaluated. We therefore assessed changes in SCD incidence, and associated factors, in CRT recipients over the last 20 years. Methods and results Literature search from inception to 30 April 2018 for observational and randomized studies involving CRT patients, with or without defibrillator, providing specific cause-of-death data. Sudden cardiac death was the primary endpoint. For each study, rate of SCD per 1000 patient-years of follow-up was calculated. Trend line graphs were subsequently constructed to assess change in SCD rates over time, which were further analysed by device type, patient characteristics, and medical therapy. Fifty-three studies, comprising 22 351 patients with 60 879 patient-years of follow-up and a total of 585 SCD, were included. There was a gradual decrease in SCD rates since the early 2000s in both randomized and observational studies, with rates falling more than four-fold. The rate of decline in SCD was steeper than that of all-cause mortality, and accordingly, the proportion of deaths which were due to SCD declined over the years. The magnitude of absolute decline in SCD was more prominent among CRT-pacemaker (CRT-P) patients compared to those receiving CRT-defibrillator (CRT-D), with the difference in SCD rates between CRT-P and CRT-D decreasing considerably over time. There was a progressive increase in age, use of beta-blockers, and left ventricular ejection fraction, and conversely, a decrease in QRS duration and antiarrhythmic drug use. Conclusion Sudden cardiac death rates have progressively declined in the CRT heart failure population over time, with the difference between CRT-D vs. CRT-P recipients narrowing considerably.


2018 ◽  
Vol 69 (9) ◽  
pp. 2461-2464
Author(s):  
Veronica Calborean ◽  
Daniela Ciobanu ◽  
Sorin Cecil Mirea ◽  
Oana Galceava ◽  
Victor Gheorman ◽  
...  

Heart failure is a disease characterized by cardiac remodeling or progressive dilation of left ventricle and a consequent reduction in contraction. Ventricular remodeling has been shown to be a negative prognostic factor alone, and therefore the most beneficial drugs are those that prevent or reduce left ventricular dilation. The pharmacological therapy of heart failure, although maximal, has proven to be not fully effective. The aim of our research was to evaluate resynchronization therapy in a lot of patients, monitoring their cardiac performance before and after cardiac resynchronization therapy.