scholarly journals High‐Sensitivity Troponin: A Clinical Blood Biomarker for Staging Cardiomyopathy in Fabry Disease

Author(s):  
Nora Seydelmann ◽  
Dan Liu ◽  
Johannes Krämer ◽  
Christiane Drechsler ◽  
Kai Hu ◽  
...  
2015 ◽  
Vol 30 (suppl_3) ◽  
pp. iii389-iii389
Author(s):  
Federico Pieruzzi ◽  
Fabio Rosario Salerno ◽  
Antonella Di Giacomo ◽  
Agnese Binaggia ◽  
Giacomo Torti ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
I Restan ◽  
O.T Steiro ◽  
H.L Tjora ◽  
J Langoergen ◽  
T Omland ◽  
...  

Abstract Background NSTEMI may be ruled out in patients presenting with acute chest pain based on low baseline high sensitivity troponin (cTn) at admission. This procedure is limited by a low expected frequency of ruled out non-cardiac chest pain (NCCP) patients. Purpose To investigate if stress-induced biomarkers (glucose or copeptin) combined with cTn can increase the rate of NCCP ruled out without an unacceptable increase in incorrectly ruled out NSTEMI. Method 971 patients with suspected NSTE-ACS were included. Final diagnosis was adjudicated by two independent cardiologists using clinical data including routine cTnT. Additionally, baseline cTnI, cTnI from Singulex Clarity System (cTnI(sgx)), copeptin and glucose were measured. Diagnostic performance to rule out NSTEMI was compared between the ESC rule out algorithms for cTnT and cTnI(Abbott), a local cTnI(sgx) algorithm and different combinations of cTn with copeptin or glucose Results Median age 61 years, 60% male. 13% had NSTEMI, 12% had UAP and 60% NCCP. Distribution of copeptin and glucose concentrations (NSTEMI and NCCP) is shown in figure 1. Copeptin and cTnT produces an algorithm with lower miss rate for NSTEMI, increased rule out rate for NCCP and significantly higher AUC (DeLong test, p value <0.001) compared to the ESC algorithm (Table 1). cTnI(sgx) and copeptin showed higher rule out for NCCP and higher AUC (p value <0.001), however an increased rule out rate for NSTEMIs. Combining cTnI(Abbott) and glucose gave a similar miss rate for NSTEMI as ESC, but increased rule out rate for NCCP and higher AUC (p value <0.001). Conclusion Combining cTnT or cTnI(sgx) with copeptin; or cTnI with glucose, improves diagnostic precision and efficacy of rule out protocols for NSTEMI in patients presenting with acute chest pain. Figure 1 Funding Acknowledgement Type of funding source: Public Institution(s). Main funding source(s): Western Norway Regional Health Authority; Haukeland and Stavanger University Hospitals


2021 ◽  
Vol 77 (12) ◽  
pp. 1487-1499
Author(s):  
Júlia Karády ◽  
Thomas Mayrhofer ◽  
Maros Ferencik ◽  
John T. Nagurney ◽  
James E. Udelson ◽  
...  

Vascular ◽  
2021 ◽  
pp. 170853812098629
Author(s):  
Bálint Nagy ◽  
Elettra Engblom ◽  
Marijana Matas ◽  
Péter Maróti ◽  
Tamás Kőszegi ◽  
...  

Objectives Perioperative stress affects the outcome of carotid endarterectomy performed under regional anesthesia. Here we aimed to explore the temporal profile of the stress marker cortisol and its relationship to high-sensitivity troponin-T, matrix metalloproteinase-9, tissue inhibitor of metalloproteinase-1, and S100B as an indicator of blood–brain barrier alteration in the systemic circulation. Methods Prospective part of the study: a total of 31 patients with significant carotid stenosis scheduled for carotid endarterectomy in regional anesthesia were enrolled. Follow-up part of the study and retrospective analysis of the outcome: each patient was followed up to five years and morbidity as well as mortality data were collected from an electronic database. Blood samples from each patient were serially taken; prior to surgery (T1), at the time of reperfusion (T2), 24 h (T3) and 72 h later postoperatively (T4), then the plasma concentration of each biomarker was measured. Besides, the clinical and surgical factors and perioperative adverse events were recorded. Results More positive correlations were found between: the early change of S100B (T2–T1) and late change in plasma cortisol level (T4–T3) (r = 0.403; p < 0.05); the early change of cortisol (T2–T1) and the early postoperative change of plasma matrix metalloproteinase-9 level (T3–T2) (r = 0.432; p = 0.01); the plasma concentration of tissue inhibitor of metalloproteinase-1 at 24 postoperative hours and the late change in plasma high-sensitivity troponin-T level (T4–T3) (r = 0.705; p < 0.001). Five patients needed an intraoperative shunt in whom the high-sensitivity troponin-T was elevated even prior to surgery, but definitive stroke never occurred. Plasma matrix metalloproteinase-9 concentration at reperfusion independently predicted the five-year mortality with a cut-off value of 456 ng/ml (sensitivity: 86%, specificity: 84%, area 0.887, p = 0.002). Conclusions A higher intraoperative change in S100B level reflecting carotid endarterectomy induced acute silent brain ischemia was associated with more pronounced post-operative change of cortisol. An early elevation of cortisol was found to be associated with a delayed increase of matrix metalloproteinase-9. Importantly, an increased high-sensitivity troponin-T even prior to carotid endarterectomy may predict clamp intolerance, and elevated matrix metalloproteinase-9 at reperfusion suggests a poor outcome.


Sign in / Sign up

Export Citation Format

Share Document