Joint Stiffness and Position Control of an Artificial Muscle Manipulator for Instantaneous Loads Using a Mechanical Equilibrium Model

2011 ◽  
Vol 25 (3-4) ◽  
pp. 387-406 ◽  
Author(s):  
Taro Nakamura ◽  
Daisuke Tanaka ◽  
Hiroyuki Maeda
2013 ◽  
Vol 43 (1) ◽  
pp. 47-60
Author(s):  
Mihail Tsveov ◽  
Dimitar Chakarov

Abstract In the paper, different approaches for compliance control for human oriented robots are revealed. The approaches based on the non- antagonistic and antagonistic actuation are compared. In addition, an approach is investigated in this work for the compliance and the position control in the joint by means of antagonistic actuation. It is based on the capability of the joint with torsion leaf springs to adjust its stiffness. Models of joint stiffness are presented in this paper with antagonistic and non-antagonistic influence of the spring forces on the joint motion. The stiffness and the position control possibilities are investigated and the opportunity for their decoupling as well. Some results of numerical experiments are presented in the paper too.


Actuators ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 17
Author(s):  
Seigo Kimura ◽  
Ryuji Suzuki ◽  
Katsuki Machida ◽  
Masashi Kashima ◽  
Manabu Okui ◽  
...  

In this paper, the prototype of the assistive suit for lower limbs was developed. The prototype was based on an assist method with joint stiffness and antagonized angle control. The assist method comprises a system consisting of a pneumatic artificial muscle and a pull spring, which changes the joint stiffness and the antagonized angle to correspond to the movement phase and aims at coordinated motion assistance with the wearer. First, the characteristics of the developed prototype were tested. It was confirmed that the measured value of the prototype followed the target value in the relationship between torque and angle. In addition, there was hysteresis in the measured value, but it did not affect the assist. Next, the evaluation of standing-up and gait assist by measuring electromyography (EMG) of the knee extensor muscle was conducted using the prototype. In all subjects, a decrease in EMG due to the assist was confirmed. In one subject, the maximum decrease rate at the peak of the EMG was about 50% for standing-up motion and about 75% for gait motion. From the results of these assist evaluations, the effectiveness of the assist method based on the joint stiffness and antagonistic angle control using the prototype was confirmed.


Sign in / Sign up

Export Citation Format

Share Document