In Vivo Evidence of Porcine Cornea Anisotropy Using Supersonic Shear Wave Imaging

2014 ◽  
Vol 55 (11) ◽  
pp. 7545 ◽  
Author(s):  
Thu-Mai Nguyen ◽  
Jean-Francois Aubry ◽  
Mathias Fink ◽  
Jeremy Bercoff ◽  
Mickael Tanter
2021 ◽  
Author(s):  
Courtney A. Trutna ◽  
Anna E. Knight ◽  
Felix Q. Jin ◽  
Ned C. Rouze ◽  
Laura S. Pietrosimone ◽  
...  

Author(s):  
Emilie Mace ◽  
Gabriel Montaldo ◽  
Mathias Fink ◽  
Mickael Tanter ◽  
Abraham Martin ◽  
...  

2013 ◽  
Vol 134 (5) ◽  
pp. 4009-4009 ◽  
Author(s):  
Mohammad Mehrmohammadi ◽  
Pengfei Song ◽  
Carolina A. Carrascal ◽  
Matthew W. Urban ◽  
Matthew R. Callstrom ◽  
...  

2011 ◽  
Vol 30 (3) ◽  
pp. 550-558 ◽  
Author(s):  
E Macé ◽  
I Cohen ◽  
G Montaldo ◽  
R Miles ◽  
M Fink ◽  
...  

2018 ◽  
Vol 40 (6) ◽  
pp. 380-393 ◽  
Author(s):  
Jaromir Vachutka ◽  
Zuzana Sedlackova ◽  
Tomas Furst ◽  
Miroslav Herman ◽  
Jan Herman ◽  
...  

Shear wave imaging is considered to be more precise and less operator dependent when compared with strain imaging. It enables quantitative and reproducible data (Young’s modulus of the imaged tissue). However, results of shear wave imaging can be affected by a variety of different factors. The aim of this study is to evaluate the effect of the pressure applied by the ultrasound probe during examination on the measured values of Young’s modulus. The effect of the tissue compression on the results of the real-time shear wave elastography was evaluated via the gelatine phantom measurements, via the ex vivo experiments with pig liver, and via the in vivo measurements of the thyroid gland stiffness on healthy volunteers. The results of our measurements confirmed that the measured value of Young’s modulus increases with the increasing pressure applied on the imaged object. The highest increase was observed during the ex vivo experiments (400%), and the lowest increase was detected in the case of the phantom measurements (8%). A two- to threefold increase in Young’s modulus was observed between the minimum and maximum pressure in the case of the in vivo elastography measurements of thyroid gland. The Veronda-Westman theoretical model was used for the description of the tissue nonlinearity. We conclude that tissue compression by the force exerted on the probe can significantly affect the results of the real-time shear wave elastography measurements. Minimum pressure should be used when measuring the absolute value of Young’s modulus of superficial organs.


2019 ◽  
Author(s):  
Stefan Schimschal ◽  
Stephen Fayers ◽  
Nicklas Ritzmann ◽  
Martin Cox ◽  
Iain Whyte

2021 ◽  
Vol 118 (2) ◽  
pp. 023702
Author(s):  
Steve Beuve ◽  
Samuel Callé ◽  
Elise Khoury ◽  
Emmanuel Gilles Simon ◽  
Jean-Pierre Remenieras

2016 ◽  
Vol 39 (3) ◽  
pp. 172-188
Author(s):  
Naoki Sunaguchi ◽  
Yoshiki Yamakoshi ◽  
Takahito Nakajima

This study investigates shear wave phase map reconstruction using a limited number of color flow images (CFIs) acquired with a color Doppler ultrasound imaging instrument. We propose an efficient reconstruction method to considerably reduce the number of CFIs required for reconstruction and compare this method with Fourier analysis-based color Doppler shear wave imaging. The proposed method uses a two-step phase reconstruction process, including an initial phase map derived from four CFIs using an advanced iterative algorithm of optical interferometry. The second step reduces phase artifacts in the initial phase map using an iterative correction procedure that cycles between the Fourier and inverse Fourier domains while imposing directional filtering and total variation regularization. We demonstrate the efficacy of this method using synthetic and experimental data of a breast phantom and human breast tissue. Our results show that the proposed method maintains image quality and reduces the number of CFIs required to four; previous methods have required at least 32 CFIs to achieve equivalent image quality. The proposed method is applicable to real-time shear wave elastography using a continuous shear wave produced by a mechanical vibrator.


Sign in / Sign up

Export Citation Format

Share Document