phantom measurements
Recently Published Documents


TOTAL DOCUMENTS

138
(FIVE YEARS 14)

H-INDEX

17
(FIVE YEARS 1)

Author(s):  
Diana Bencikova ◽  
Fei Han ◽  
Stephan Kannengieser ◽  
Marcus Raudner ◽  
Sarah Poetter-Lang ◽  
...  

Abstract Objectives T2 mapping of the liver is a potential diagnostic tool, but conventional techniques are difficult to perform in clinical practice due to long scan time. We aimed to evaluate the accuracy of a prototype radial turbo-spin-echo (rTSE) sequence, optimized for multi-slice T2 mapping in the abdomen during one breath-hold at 3 T. Methods A multi-sample (fat: 0–35%) agarose phantom doped with MnCl2 and 80 subjects (73 patients undergoing abdomen MR examination and 7 healthy volunteers) were investigated. A radial turbo-spin-echo (rTSE) sequence with and without fat suppression, a Cartesian turbo-spin-echo (Cart-TSE) sequence, and a single-voxel multi-echo STEAM spectroscopy (HISTO) were performed in phantom, and fat-suppressed rTSE and HISTO sequences were performed in in vivo measurements. Two approaches were used to sample T2 values: manually selected circular ROIs and whole liver analysis with Gaussian mixture models (GMM). Results The rTSE-T2s values exhibited a strong correlation with Cart-TSE-T2s (R2 = 0.988) and with HISTO-T2s of water (R2 = 0.972) in phantom with an offset between rTSE and Cart-TSE maps (mean difference = 3.17 ± 1.18 ms). The application of fat suppression decreased T2 values, and the effect was directly proportional to the amount of fat. Measurements in patients yielded a linear relationship between rTSE- and HISTO-T2s (R2 = 0.546 and R2 = 0.580 for ROI and GMM, respectively). Conclusion The fat-suppressed rTSE sequence allows for fast and accurate determination of T2 values of the liver, and appears to be suitable for further large cohort studies. Key Points •Radial turbo-spin-echo T2 mapping performs comparably to Cartesian TSE-T2 mapping, but an offset in values is observed in phantom measurements. •Fat-suppressed radial turbo-spin-echo T2 mapping is consistent with T2 of water as assessed by MRS in phantom measurements. •Fat-suppressed radial turbo-spin-echo sequence allows fast T2 mapping of the liver in a single breath-hold and is correlated with MRS-based T2 of water.


2021 ◽  
Vol 94 (1124) ◽  
pp. 20210068
Author(s):  
Caroline Ordóñez-Sanz ◽  
Mark Cowen ◽  
Neda Shiravand ◽  
Niall D MacDougall

Objectives: A simple, robust method, for optimising cone-beam CT (CBCT) dose and image quality for pelvis treatment, based on patient-specific attenuation. Methods: Methods were investigated for grouping patients into four imaging categories (small [S], medium [M], large [L], extra large [XL]), based on planning-CT CTDIvol, and phantoms constructed to represent each group. CBCTs with varying kV, mA and ms honed in on the best settings, with a bladder noise of 25 HU. A patient pilot study clinically verified the new imaging settings. Results: The planning CTDIvol is a reliable method for grouping patients. Phantom measurements from the S, M and L groups show doses significantly reduced (19–83% reduction), whilst the XL group required an increase of 39%. Phantom TLD measurements showed the number of scans needed to increase rectal organ at risk (OAR) dose by 1 Gy was 143 (S group) and 50 (M group). Images were qualitatively assessed as sufficient by clinicians. Conclusion: Patient-specific CBCT modes are in use clinically with dose reductions across all modes except Pelvis XL, keeping doses ALARP and images optimal. Consideration of OAR doses controls the number of CBCTs allowed to ensure adherence to OAR tolerance. Reporting CBCT doses in “scans per Gray” allows clinicians to make informed decisions regarding the imaging schedule and concomitant doses. Advances in knowledge: Patient grouping at planning CT, using CTDIvol, allows for CBCT imaging protocols to be selected based on patient specific attenuation. Reporting OAR doses in terms of “scans per Gray” allows translation of imaging dose risk to the Oncologist.


Author(s):  
Imke Schatka ◽  
Anne Bingel ◽  
Franziska Schau ◽  
Stephanie Bluemel ◽  
Daniel R. Messroghli ◽  
...  

Abstract Background In [99mTc]Tc-DPD scintigraphy for myocardial ATTR amyloidosis, planar images 3 hour p.i. and SPECT/CT acquisition in L-mode are recommended. This study investigated if earlier planar images (1 hour p.i.) are beneficial and if SPECT/CT acquisition should be preferred in H-mode (180° detector angle) or L-mode (90°). Methods In SPECT/CT phantom measurements (NaI cameras, N = 2; CZT, N = 1), peak contrast recovery (CRpeak) was derived from sphere inserts or myocardial insert (cardiac phantom; signal-to-background ratio [SBR], 10:1 or 5:1). In 25 positive and 38 negative patients (reference: endomyocardial biopsy or clinical diagnosis), Perugini scores and heart-to-contralateral (H/CL) count ratios were derived from planar images 1 hour and 3 hour p.i. Results In phantom measurements, accuracy of myocardial CRpeak at SBR 10:1 (H-mode, 0.95-0.99) and reproducibility at 5:1 (H-mode, 1.02-1.14) was comparable for H-mode and L-mode. However, L-mode showed higher variability of background counts and sphere CRpeak throughout the field of view than H-mode. In patients, sensitivity/specificity were ≥ 95% for H/CL ratios at both time points and visual scoring 3 hour. At 1 hour, visual scores showed specificity of 89% and reduced reader’s confidence. Conclusions Early DPD images provided no additional value for visual scoring or H/CL ratios. In SPECT/CT, H-mode is preferred over L-mode, especially if quantification is applied apart from the myocardium.


Author(s):  
E. O. Sannikova ◽  
I. M. Lebedenko ◽  
S. S. Khromov ◽  
G. E. Gorlachev

Purpose: The assessment of the dose load on a pregnant patient during irradiation of the oropharyngeal tumor at different distances from the border of the irradiated field, including at the level corresponding to the position of the fetus, based on phantom measurements.Material and methods: To calculate the exposure plan, the ECLIPSE planning system with the AAA algorithm was used. Irradiation was performed on a LinacClinaciX (Varian, USA) with a nominal photon energy of 6 MeV. The tissue equivalent phantom Alderson–Rando was used to assess the dose load on the fetus.Results and conclusions: It was shown that the total absorbed dose at the level and below the diaphragm (the level of the fetus) at a distance of more than 40 cm from the border of the irradiation field for the entire course of radiation therapy turned out to be significantly less than the permissible limits indicated in the literature and amounted from 41.71 to 14.03 mGy. 


Author(s):  
Christina E. Agnew ◽  
Candice McCallum ◽  
Gail Johnston ◽  
Adam Workman ◽  
Denise M. Irvine

Abstract Purpose: The aim of this study was to optimise patient dose and image quality of Varian TrueBeam cone beam computed tomography (CBCT) pelvis, thorax and head and neck (H&N) images based on patient size. Methods: An elliptical phantom of small, medium and large size was designed representative of a local population of pelvis, thorax and H&N patients. The phantom was used to establish the relationship between image noise, CT and CBCT exposure settings. Using this insight, clinical images were optimised in phases and the image quality graded qualitatively by radiographers. At each phase, the time required to match the images was recorded from the record and verify system. Results: Average patient diameter was a suitable metric to categorise patient size. Phantom measurements showed the power relationship between noise and CBCT exposure settings of value −0·15, −0·35 and −0·43 for thorax, pelvis and H&N, respectively. These quantitative phantom measurements provided confidence that phased variation of ~±20% in mAs should result in clinically usable images. Qualitative assessment of almost 2000 images reduced the exposure settings in H&N images by −50%, thorax images by up to −66% and pelvis images by up to −80%. These optimised CBCT settings did not affect the time required to match images. Findings: Varian TrueBeam CBCT mAs settings have been optimised for dose and image quality based on patient size for three treatment sites: pelvis, thorax and H&N. Quantitative phantom measurements provided insight into the magnitude of change to implement clinically. The final optimised exposure settings were determined from radiographer qualitative image assessment.


2020 ◽  
pp. 028418512098328
Author(s):  
Andreas Österlund ◽  
Wilfried Drohn ◽  
Herbert Hoedlmoser ◽  
Matthias Greiter ◽  
Martin Schmid ◽  
...  

Background The radiation dose to staff performing endoscopic retrograde cholangiopancreatography (ERCP) is not negligible. Purpose To evaluate the shielding effect of a table-suspended lower-body radiation shield for the positions in the room occupied by the operator, assisting nurse, and anesthesiologist, used during ERCP procedures with a mobile C-arm. Material and Methods Eye lens dose, whole body dose, and extremity dose were measured with and without a table-suspended lower-body radiation shield in a phantom model and in clinical routine work. The effect of the shield was evaluated for each scenario and compared, and a projection was made for when shielding should be required from a regulatory point of view. Results In the phantom measurements, the shield provided significant shielding effects on the body and lower extremities for the operator but no significant shielding of the eye lens. The shielding effect for the assisting nurse was limited to the lower extremity. The clinical measurements yielded the same general result as the phantom measurements, with the major difference that the shield provided no significant reduction in the whole-body dose to the operator. Conclusion The table-suspended shield has a significant shielding effect for the lower extremities of the operator and assisting nurse. For annual dose–area product values >300,000 cGycm2, the protection of the operator should be reinforced with a ceiling-suspended shield to avoid doses to the eye lens and body in excess of regulatory dose restrictions.


2020 ◽  
Vol 47 (6) ◽  
pp. 2408-2412 ◽  
Author(s):  
René Werner ◽  
Thilo Sentker ◽  
Frederic Madesta ◽  
Annette Schwarz ◽  
Marc Vornehm ◽  
...  