scholarly journals External Quality Assessment of Urinary-Free Cortisol Measurement in the UK against a Gas Chromatography Mass Spectroscopy Reference Method

Author(s):  
G. Holder
1999 ◽  
Vol 45 (9) ◽  
pp. 1536-1542 ◽  
Author(s):  
Jan Møller ◽  
Karsten Rasmussen ◽  
Lene Christensen

Abstract Background: The use of analyses for methylmalonic acid (MMA) and total homocysteine (HCY) in plasma has become widespread. Realizing the need for external quality assessment for these measurements, we started a program in 1997. The results for 1998 are reviewed in this report. Methods: Fourteen laboratories participated with 15 sets of results for MMA, and 28 laboratories participated with 34 sets of results for HCY. Results for four identical samples, made up from the same unmodified serum (MMA) or EDTA-plasma (HCY) pool, sent out under different identifications, were used for assessing the imprecision. Samples made up from the same pools supplemented with MMA or l-HCY to three concentrations were used for assessing the recovery. By using literature data for the biological variation, quality goals for both analytes were calculated. Results: The overall within-laboratory CV was 12% for MMA and 7.5% for HCY. Gas chromatography–mass spectrometric HCY results had lower imprecision than the HPLC or immunoassay results. For MMA, no significant between-laboratory component of variance was found. Only results for HCY obtained with HPLC methods showed significant between-laboratory variance. Conclusions: Eight of the 15 participants achieved the minimum imprecision goal for MMA vs 9 of the 34 participants for HCY. The minimum quality goals for bias as approximated by the recovery were achieved by 13 participants for MMA and 26 for HCY.


1993 ◽  
Vol 39 (6) ◽  
pp. 993-1000 ◽  
Author(s):  
D Stöckl ◽  
H Reinauer

Abstract In Germany, the target values for External Quality Assessment (EQA) and internal accuracy control are determined by Reference Methods for several analytes, including cholesterol, creatinine, uric acid, and glucose. We present candidate Reference Methods for these compounds, based on isotope dilution-gas chromatography--mass spectrometry methods that have been developed at INSTAND, one of the two official Germany EQA reference institutions. Each Reference Method target value is calculated from six independent measurements performed on three different days. The mean method CVs ranged from 0.66% for glucose to 0.96% for creatinine. The inaccuracy (bias) of the methods is < 0.7%, as compared with the Standard Reference Material 909 of the National Institute of Standards and Technology. The maximum total error of a Reference Method value, including the 95% confidence interval and systematic errors, is < 2.3%. The presented candidate Reference Methods have been successfully used to set target values in the German EQA scheme and the internal accuracy control of routine laboratories.


Author(s):  
G H Beastall ◽  
K M Ferguson ◽  
D ST J O'reilly ◽  
J Seth ◽  
B Sheridan

The measurement of serum follicle stimulating hormone (FSH) and luteinising hormone (LH), together with the appropriate sex steroid, is of great value in the investigation of delayed and precocious puberty, hypogonadism, subfertility, polycystic ovarian disease and hypothalamic-pituitary disorders. Dynamic function testing of the hypothalamic-pituitary-gonadal axis should be restricted to a few defined situations. Sequential LH measurements, either in serum or in urine, may be used to time ovulation during artificial insemination or in vitro fertilisation programmes. No special precautions are necessary when sampling for FSH and LH measurement; serum is preferred to plasma and should be stored frozen before assay. Aliquots of timed urine specimens of known volume should be stored frozen without preservative. Gonadotropin results should be available within 2–3 weeks; laboratories unable to meet this schedule are advised to send their samples to a Regional Centre for assay. Reagents for the radioimmunoassay of FSH and LH are readily available, and standard techniques have been developed for their use. Laboratories using ‘in-house’ methods should pay particular attention to the matrix used for preparing standard solutions, the purification of radioligands and the optimisation of the separation system. Low cost matched reagents of proven performance are available in kit form from the Chelsea Hospital for Women; several commercial kits are also available, although few are widely used in the UK. The overall performance of laboratories in the UK External Quality Assessment Scheme (EQAS) for FSH and LH has remained steady for several years. Of the 130 participants, only about 15% in each scheme have ‘good’ performance (cumulative bias less than 10%, plus cumulative variability of bias less than 10%), whilst a similar proportion have ‘unacceptable’ performance (cumulative bias greater than 20% and/or cumulative variability of bias greater than 25%). The remaining 70% of laboratories have ‘adequate’ performance but are at risk of producing results that are clinically misleading. Within any one method group, the performance of FSH and LH assays are closely related. Optimal assay performance depends upon sensible laboratory management to ensure skilled operators, a regular programme of reagent/kit renewal, comprehensive internal and external quality assessment, and attention to detail in all aspects of gonadotrophin assay. The working range of each individual assay should be defined and no absolute result reported from outside this range. Mean intra-assay and interassay coefficients of variation on selected human serum quality control pools should be better than 8% and 15%, respectively, for both gonadotrophins. All laboratories performing FSH and LH assays should belong to the UK EQAS for gonadotrophins. Immunometric assays, using monoclonal antibodies, will supersede radioimmunoassays for FSH and LH during the next few years. Some of these assays will have non-isotopic labels.