Influence of Acetabular Component Position in Non-Cemented Total Hip Arthroplasty

1988 ◽  
Vol 29 (6) ◽  
pp. 746-748 ◽  
Author(s):  
A. Wykman ◽  
B. K. S. Sanjay ◽  
V. Söderlund ◽  
I. Goldie

Radiologic grading of non-cemented acetabular components in HP Garches total hip replacements was used to evaluate the relationship between a lack of supero-lateral cover of the acetabular component and clinical outcome. In 63 hips, three to five years after total hip arthroplasty, we observed that the acetabular component was partially uncovered in 56 per cent of cases. The fact that several components were partially uncovered did not influence the clinical outcome. Although the follow-up time is short the present study indicates that non-cemented HP Garches total hip arthroplasty is a technique which allows for stable fixation of the acetabular component.

2002 ◽  
Vol 10 (2) ◽  
pp. 165-169 ◽  
Author(s):  
DA Stanton ◽  
WJ Bruce ◽  
JA Goldberg ◽  
W Walsh

Purpose. To review cases of implantation of constraining acetabular components for unstable or recurrent dislocating total hip arthroplasty at the Department of Orthopaedics, Concord Hospital, Sydney. Methods. A retrospective analysis was performed on prospectively collected data of 13 consecutively enrolled patients. Results. From 1989 to 2000, 13 constraining acetabular components were implanted into 13 patients as a revision procedure. The surgical approach for the implantation of the constrained liner was posterolateral in 11 cases; a modified Hardinge approach was applied in 2 cases. The mean clinical follow-up duration was 43 months (range, 14–121 months) and the mean age at the time of surgery was 73 years (range, 52–84 years). No patients were lost to follow-up. Indications for using the constrained acetabular component were recurrent dislocation in revision hip replacements (n=8), and intra-operative instability (n=5). There were no episodes of dislocation of the constrained arthroplasty. In 7 cases, the constrained component was implanted into a previously well-fixed shell. Conclusion. We recommend the judicious use of the constrained component in cases of hip instability during or after total hip arthroplasty when other methods are not successful.


2021 ◽  
Vol 103-B (10) ◽  
pp. 1604-1610
Author(s):  
Yusuke Takaoka ◽  
Koji Goto ◽  
Jiro Tamura ◽  
Yaichiro Okuzu ◽  
Toshiyuki Kawai ◽  
...  

Aims We aimed to evaluate the long-term outcome of highly cross-linked polyethylene (HXLPE) cemented acetabular components and assess whether any radiolucent lines (RLLs) which arose were progressive. Methods We retrospectively reviewed 170 patients who underwent 187 total hip arthroplasties at two hospitals with a minimum follow-up of ten years. All interventions were performed using the same combination of HXLPE cemented acetabular components with femoral stems made of titanium alloy. Kaplan-Meier survival analysis was performed for the primary endpoint of acetabular component revision surgery for any reason and secondary endpoint of the appearance of RLLs. RLLs that had appeared once were observed over time. We statistically assessed potential relationships between RLLs and a number of factors, including the technique of femoral head autografting and the Japanese Orthopaedic Association score. Results The mean follow-up period was 13.0 years (10.0 to 16.3). Femoral head autografting was performed on 135 hips (72.2%). One acetabular component was retrieved because of deep infection. No revision was performed for the aseptic acetabular loosening. The Kaplan-Meier survival curve for the primary and secondary endpoints were 98.2% (95% confidence interval (CI) 88.6% to 99.8%) and 79.3% (95% CI 72.8% to 84.6%), respectively. RLLs were detected in 38 hips (21.2%), at a mean of 1.7 years (1 month to 6 years) postoperatively. None of the RLLs were progressive, and the presence of RLLs did not show a significant association with the survival and clinical score. RLLs were more frequently observed in hips without femoral head autografts than in those with autografts. Conclusion The use of HXLPE cemented acetabular components in total hip arthroplasty demonstrated excellent clinical outcomes after ten years, and no RLLs were progressive, and their presence did not affect the outcome. Femoral head autografting did not negatively impact the acetabular component survival or the appearance of RLLs. Cite this article: Bone Joint J 2021;103-B(10):1604–1610.


2021 ◽  
Vol 2 (1) ◽  
pp. 33-39
Author(s):  
Jeffrey R. McLaughlin ◽  
Kyla R. Lee ◽  
Mary Ann Johnson

Aims We present the clinical and radiological results at a minimum follow-up of 20 years using a second-generation uncemented total hip arthroplasty (THA). These results are compared to our previously published results using a first-generation hip arthroplasty followed for 20 years. Methods A total of 62 uncemented THAs in 60 patients were performed between 1993 and 1994. The titanium femoral component used in all cases was a Taperloc with a reduced distal stem. The acetabular component was a fully porous coated threaded hemispheric titanium shell (T-Tap ST). The outcome of every femoral and acetabular component with regard to retention or revision was determined for all 62 THAs. Complete clinical follow-up at a minimum of 20 years was obtained on every living patient. Radiological follow-up was obtained on all but one. Results Two femoral components (3.2%) required revision. One stem was revised secondary to a periprosthetic fracture one year postoperatively and one was revised for late sepsis. No femoral component was revised for aseptic loosening. Six acetabular components had required revision, five for aseptic loosening. One additional acetabular component was revised for sepsis. Radiologically, all femoral components remained well fixed. One acetabular was judged loose by radiological criteria. The mean Harris Hip Score improved from 46 points (30 to 67) preoperatively to 89 points (78 to 100) at final follow-up. With revision for aseptic loosening as the endpoint, survival of the acetabular component was 95% (95% confidence interval (CI) 90 to 98) at 25 years. Femoral component survival was 100%. Conclusion The most significant finding of this report was the low prevalence of aseptic loosening and revision of the femoral component at a mean follow-up of 22 years. A second important finding was the survival of over 90% of the hemispheric threaded ring acetabular components. While these shells remain controversial, in this series they performed well. Cite this article: Bone Jt Open 2021;2(1):33–39.


2018 ◽  
Vol 29 (2) ◽  
pp. 222-225
Author(s):  
William Stickney ◽  
Richard S Yoon ◽  
Jay N Patel ◽  
David S Klein ◽  
George J Haiduekwych ◽  
...  

Introduction: In the revision setting, intrapelvic acetabular components provide a unique set of challenges for the treating surgeon. Retrieval is complicated by complex anatomical relationships within the pelvis and historically, surgeons have used multiple approaches to safely retrieve the cup. Case presentation: We present the case of a 53-year-old female with intrapelvic migration of the acetabular components of her total hip arthroplasty. Patient was treated through a novel, single incision approach with utilisation of an anterior inferior iliac spine (AIIS) osteotomy. Results: An AIIS osteotomy allows for improved visualisation within the pelvis and safe retrieval through a single exposure without compromising the ability to perform definitive, revision reconstruction. At 1-year follow-up, the patient has had no complications related to infection or failure of the implants. Ambulation is performed with the aid of a cane in the community with mild, occasional pain.


2022 ◽  
Vol 11 (2) ◽  
pp. 346
Author(s):  
Ali Darwich ◽  
Kim Pankert ◽  
Andreas Ottersbach ◽  
Marcel Betsch ◽  
Sascha Gravius ◽  
...  

The aim of this study was to investigate the radiological and clinical outcome of the direct anterior approach (DAA) in total hip arthroplasty (THA) using a collared cementless femoral short-stem. This retrospective study included 124 patients with 135 THAs operated from 2014 to 2016 using a collared cementless triple tapered hydroxyapatite-coated femoral short-stem (AMIStem H Collared®, Medacta International, Castel San Pietro, Switzerland) implanted with a DAA. Follow-up was performed at three months, 12 months, and five years. Clinical outcome was assessed using the hip osteoarthritis outcome score (HOOS) and radiological analysis was done using conventional radiographs, which included evaluation of the femur morphology based on Dorr classification, of radiolucencies based on the Gruen zone classification and of stem subsidence. The mean age was 67.7 ± 11.3 years and the mean body mass index (BMI) was 27.4 ± 4.4 kg/m2. The stem survival rate at five years was 99.1% with one revision due to recurrent dislocations. Mean HOOS score improved from 40.9 ± 18.3 preoperatively to 81.5 ± 19.7 at three months, 89.3 ± 10.9 at 12 months, and 89.0 ± 14.0 at five years (all with p < 0.001). No significant correlations were found between age, femoral bone morphology, BMI and HOOS, and the appearance of relevant radiolucencies.


Joints ◽  
2020 ◽  
Author(s):  
Christian Carulli ◽  
Giacomo Sani ◽  
Fabrizio Matassi ◽  
Roberto Civinini ◽  
Massimo Innocenti

Abstract Purrpose Metal-on-metal (MoM) total hip arthroplasty (THA) has been a subject of recent discussion and concern due to the early failures caused by local and systemic adverse reactions related to specific designs. The aim of this study is to analyze the outcomes and survival rates of a single brand of MoM implants implanted in a consecutive series of patients at a single institution. Methods Between 2007 and 2012, 116 (118 hips) patients were evaluated at a mean follow-up of 6.6 years after primary THA. The diagnosis leading to surgery was osteoarthritis (80 patients) and proximal femoral fracture (36 patients). A single design of THA was implanted. All patients were evaluated before surgery and postoperatively at 1, 3, 6, and 12 months by clinical scores and radiographic studies. The data analysis was made using Student's t-test. Results The minimum follow-up was of 4 years, with a mean follow-up of 6.6 years. Two aseptic loosenings of the acetabular component were recorded (one per group), which were not associated with local or systemic complications related to metal ion release. Both were revised by an isolated acetabular cup substitution with metal-on-polyethylene couplings. Nonprogressive radiolucency lines < 2 mm in zone 2 were observed in other six patients around the acetabular component without clinical manifestation (four in the arthritis group and two in the fracture group). Postoperative Harris Hip Score and SF-36 (36-Item Short Form Survey) score improved in both groups. Conclusion Despite several MoM implants showing early complications and failures, a specific MoM design may be associated with good clinical results at a mid- to long-term follow-up. Level of Evidence This is a therapeutic case series, Level 4 study.


2019 ◽  
Vol 03 (04) ◽  
pp. 176-180 ◽  
Author(s):  
Joshua A. Lawson ◽  
Andrew T. Garber ◽  
Jeffrey D. Stimac ◽  
Rama Ramakrishnan ◽  
Langan S. Smith ◽  
...  

AbstractAcetabular component malpositioning is a frequent cause of complications in total hip arthroplasty including instability, increased wear, osteolysis, impingement, and revision surgery. Recently, robotics and navigation have been introduced to improve cup positioning in total hip arthroplasty. The purpose of this study was to compare the accuracy of postoperative acetabular component positioning using MAKO robotic-assisted versus manual acetabular component placement. A consecutive series of 100 total hip replacements were performed in 100 patients. The first 50 were performed using manual techniques, while the second 50 were performed using MAKO-guided acetabular component placement. Postoperative anteroposterior pelvis radiographs were used to determine the postoperative anteversion and inclination of the cup relative to the goal of 15 and 45°, respectively. In the manual group, the average anteversion and inclination was 14.3 and 44.2°, respectively, with 28% within 5° and 82% within 10° of the goal alignment, respectively. In the robotic group, the average anteversion and inclination was 15.1 and 45.6°, respectively, with 54 and 88% within 5 and 10° of the goal alignment, respectively. This equated to a statistically significant improvement in the number of acetabular components placed within 5° of the target alignment with the use of robotic guidance (p = 0.0142). From the authors' study, they were able to demonstrate a significant improvement in acetabular component alignment with the use of robotic techniques. Additional studies are needed to demonstrate improvement in clinical outcomes as a result of improved accuracy and precision of acetabular component placement.


2018 ◽  
Vol 100-B (11) ◽  
pp. 1434-1441 ◽  
Author(s):  
W. G. Blakeney ◽  
Y. Beaulieu ◽  
B. Puliero ◽  
M. Lavigne ◽  
A. Roy ◽  
...  

Aims This study reports the mid-term results of total hip arthroplasty (THA) performed using a monoblock acetabular component with a large-diameter head (LDH) ceramic-on-ceramic (CoC) bearing. Patients and Methods Of the 276 hips (246 patients) included in this study, 264 (96%) were reviewed at a mean of 67 months (48 to 79) postoperatively. Procedures were performed with a mini posterior approach. Clinical and radiological outcomes were recorded at regular intervals. A noise assessment questionnaire was completed at last follow-up. Results There were four re-operations (1%) including one early revision for insufficient primary fixation (0.4%). No hip dislocation was reported. The mean University of California, Los Angeles (UCLA) activity score, 12-Item Short-Form Health Survey (SF-12) Mental Component Summary (MCS) score, SF-12 Physical Component Summary (PCS) score, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, and Forgotten Joint Score (FJS) were 6.6 (2 to 10), 52.8 (25.5 to 65.7), 53.0 (27.2 to 66.5), 7.7 (0 to 63), and 88.5 (23 to 100), respectively. No signs of loosening or osteolysis were observed on radiological review. The incidence of squeaking was 23% (n = 51/225). Squeaking was significantly associated with larger head diameter (p < 0.001), younger age (p < 0.001), higher SF-12 PCS (p < 0.001), and UCLA scores (p < 0.001). Squeaking did not affect patient satisfaction, with 100% of the squeaking hips satisfied with the surgery. Conclusion LDH CoC THAs have demonstrated excellent functional outcomes at medium-term follow-up, with very low revision rate and no dislocations. The high incidence of squeaking did not affect patient satisfaction or function. LDH CoC with a monoblock acetabular component has the potential to provide long term implant survivorship with unrestricted activity, while avoiding implant impingement, liner fracture at insertion, and hip instability. Cite this article: Bone Joint J 2018;100-B:1434–41.


2006 ◽  
Vol 309-311 ◽  
pp. 1357-1362
Author(s):  
Masahiro Hasegawa ◽  
Akihiro Sudo ◽  
Atsumasa Uchida

In ceramic-on-ceramic total hip arthroplasty (THA), modular acetabular component with a sandwich insertion was developed and evaluated mid-term clinical results. 35 hips had undergone cementless ceramic-on-ceramic THA with sandwich cup (Kyocera, Kyoto, Japan). The mean duration of follow-up was 5 years. 6 hips had undergone component revisions. The reasons for revision included infection in 1 hip, dislocation with loosening in 2 hips, alumina liner fractures in 2 hips, and cup dissociation in 1 hip. All femoral and acetabular components showed no loosening in the unrevised hips at the time of the last follow-up. None of the 29 unrevised hips had osteolysis.