scholarly journals Effect of vertical cut on coronal coverage and rotation of tibial component in Oxford unicompartmental knee arthroplasty

2020 ◽  
Vol 48 (5) ◽  
pp. 030006052092242
Author(s):  
Guanghan Gao ◽  
Zheng Li ◽  
Yannong Wang ◽  
Guangzhong Yang ◽  
Jiang Huang ◽  
...  

Objective This study was performed to investigate the influence of a standard Oxford vertical cut on the coronal coverage and rotation of the tibial component and determine whether a relationship exists between coverage and rotation. Methods We retrospectively analyzed 71 patients with anteromedial osteoarthritis of the knee treated by Oxford unicompartmental knee arthroplasty in one center from October 2016 to October 2017. The distance of coronal coverage was measured on a postoperative anteroposterior view of the tibial component. Two different reference lines between the lateral wall of the tibial component were defined as rotation angle α and β, respectively, on a computed tomography scan. Results The mean distance was 0.3 ± 1.1 mm. The mean angle α and β were 5.7° ± 4.6° and 8.4° ± 4.6°, respectively. There were no significant differences in the distance according to the tibial component rotation or in the α and β angles according to the coronal coverage. No significant correlation was found between the α and β angles and the distance. Conclusion A standard tibial vertical cut caused various changes in coronal coverage and rotation of the tibial component. The rotation of the tibial component did not affect coverage within a certain range.

Author(s):  
Yuichi Kuroda ◽  
Koji Takayama ◽  
Kazunari Ishida ◽  
Shinya Hayashi ◽  
Shingo Hashimoto ◽  
...  

AbstractSince a hindfoot alignment is not included in the conventional mechanical axis (hip–ankle [HA] line), a mechanical axis including the calcaneus (hip–calcaneus [HC] line) has recently attracted attention as an alternative weight-bearing line. However, there are few reports on unicompartmental knee arthroplasty (UKA) regarding the HC line. Therefore, this study aimed to compare postoperative alignments after UKA between the HA line and the HC line. Postoperatively, HC radiographs were taken in 88 consecutive patients who underwent medial UKA. The hip–knee–ankle (HKA) and hip–knee–calcaneus (HKC) angles were compared in the same patient. Regarding tibial inclination, the conventional tibial component–ankle (TCA) angle was compared with reference to the HC line (tibial component–calcaneus [TCC] angle). The mean postoperative HKA and HKC angles were 2.8 ± 2.7 and 2.0 ± 2.5 degree, respectively. The mean postoperative TCA and TCC angles were 87.7 ± 2.1 and 88.5 ± 2.1 degree, respectively. There were significant differences between the two groups in both lower limb alignment and tibial component angle. The present study indicated that the HKC and the TCC angles significantly decreased the varus alignment by approximately 1 degree compared with the HKA and TCA angles. Neutral in the HA line corresponds to valgus in reference to the HC line, which may result in overcorrection. Surgeons should consider evaluating the HC line in place of the HA line, which may affect preoperative planning and postoperative outcome during UKA. This is a Level II, diagnostic study.


The Knee ◽  
2018 ◽  
Vol 25 (6) ◽  
pp. 1222-1230 ◽  
Author(s):  
Tomoyuki Kamenaga ◽  
Takafumi Hiranaka ◽  
Kenichi Kikuchi ◽  
Yuichi Hida ◽  
Takaaki Fujishiro ◽  
...  

2019 ◽  
Vol 34 (11) ◽  
pp. 2606-2613 ◽  
Author(s):  
Tomoyuki Kamenaga ◽  
Takafumi Hiranaka ◽  
Koji Takayama ◽  
Masanori Tsubosaka ◽  
Ryosuke Kuroda ◽  
...  

2015 ◽  
Vol 2015 ◽  
pp. 1-5 ◽  
Author(s):  
Tadashi Fujii ◽  
Yoshio Matsui ◽  
Marehoshi Noboru ◽  
Yusuke Inagaki ◽  
Yoshinori Kadoya ◽  
...  

We experienced two cases of atypical lateral dislocations of meniscal bearing in UKA (unicompartmental knee arthroplasty) without manifest symptoms. The dislocated bearing, which jumped onto the wall of tibial components, was found on radiographs in periodic medical examination although they could walk. Two thicker size bearing exchanges were promptly performed before metallosis and loosening of components. Continual examination is important to mobile bearing type of UKA because slight or less symptoms may disclose such unique dislocation. One case showed malrotation of the femoral component on 3D image. Anteroposterior view hardly disclosed the malrotation of the femoral component. Epicondylar view is an indispensable view of importance, and it can demonstrate the rotation of the femoral component. The the femoral distal end is wedge shaped and is wider posteriorly. If the femoral component is set according to the shape of medial condyle, the femoral component shifts to medial site compared with tibial component in flexion. It can account for such rare dislocation as follows. If excessive force applies on most medial side of the bearing during flexion, the lateral part of the bearing pops and the force squeezes it laterally simultaneously. Finally, the bearing jumps onto the lateral wall of the tibial component.


Author(s):  
D. M. Moore ◽  
G. A. Sheridan ◽  
A. Welch-Phillips ◽  
J. M. O’Byrne ◽  
P. Kenny

Abstract Purpose Unicompartmental knee arthroplasty (UKA) provides patients with an alternative treatment to TKA in isolated medial compartment osteoarthritis providing better functional outcomes and faster recovery in the short term. Our aim was to quantify revision rates, predictors of revision, mortality rate and functionality of the Oxford Phase 3 UKA in a non-designer institution. Methods This was a retrospective review of prospectively collected regional registry data. All Oxford Phase 3 UKAs performed for medial tibio-femoral osteoarthritis of the knee joint were included from a single academic institution between the period of January 1st 2006 and December 30th 2009. Kaplan-Meier survivorship curves adjusting for loss to follow-up and deceased patients were generated. Primary outcome variables included all-cause and aseptic revision. Secondary outcome variables included functional outcome scores. Patients were reviewed at 6 months, 2 years, 5 years, 10 years and 15 years. Results A total of 64 cemented Oxford phase 3 UKAs were performed between January 2006 and November 2009. Fifteen-year follow-up data were available for 51 patients, of these 12 required revision. Survival rates, adjusting for patients that were either lost to follow-up or deceased, were 87.5% at 5 years, 81.4% at 10 years and 76.4% at 15 years. The overall aseptic revision rate at the time of review was 18.75% (n = 12). The only significant predictor of postoperative WOMAC score at 15 years was the preoperative WOMAC score (p = 0.03). Conclusion The Oxford Phase 3 UKA for medial tibio-femoral arthritis has promising outcomes at 15-year follow-up with a survival rate of 76.4% in a non-designer centre. Level of Evidence III.


2021 ◽  
Author(s):  
Jirayu Paugchawee ◽  
Chaturong Pornrattanamaneewong ◽  
Pakpoom Ruangsomboon ◽  
Rapeepat Narkbunnam ◽  
Keerati Chareancholvanich

Abstract Background: Oxford unicompartmental knee arthroplasty (OUKA) yields favorable outcomes in patients with medial compartmental knee osteoarthritis; however, it remains unknown whether cemented or cementless OUKA fixation delivers better outcomes in Asian population. Accordingly, this study aimed to investigate the complications, reasons for reoperation, and 5-year prosthesis survival compared between cemented and cementless OUKA in Thai patients.Methods: A total of 466 cemented and 36 cementless OUKA that were performed during 2011-2015 with a minimum follow-up of five years were included. With reoperation for any reason as the endpoint, Kaplan-Meier analysis was performed to compare 5-year implant survival between groups. Complications, reasons for reoperation, and 90-day morbidity and mortality were compared between groups. Cox proportional hazards model was used to identify independent predictors of implant survival.Results: There was no significant difference in 5-year implant survival between the cemented and cementless groups (96.4% vs. 94.4%, p=0.375). The mean implant survival time was 113.0±0.8 and 70.8±1.9 months in the cemented and cementless groups, respectively (p=0.383). The most common reason for reoperation was bearing dislocation, and only one patient had 90-day morbidity. There was no significant difference between groups for complications or reasons for reoperation. No independent predictors of implant survival were identified in multivariate analysis.Conclusions: OUKA was shown to be a safe and durable reconstructive procedure in Thai patients with medial compartmental knee osteoarthritis. There was no significant difference in implant survival between the cemented and cementless groups during the 5-year follow-up, and no independent predictors of implant survival were identified. Trial registration: Thai Clinical Trials Registry, TCTR20200427004. Registered 27 April 2020 – Retrospectively registered.


2008 ◽  
Vol 57 (4) ◽  
pp. 635-638
Author(s):  
Tetsuya Fukumoto ◽  
Kazutoshi Nomura ◽  
Noburo Hashimoto ◽  
Satoshi Maeda ◽  
Haruhiko Chuma ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document