Mechanical and numerical characterization of ceramic femoral components for hip resurfacing arthroplasty

Author(s):  
Danny Vogel ◽  
Martin Liebelt ◽  
Florian Kalkowsky ◽  
Thomas Oberbach ◽  
Daniel Delfosse ◽  
...  

Hip resurfacing arthroplasty may have distinct advantages for young and active patients, but large metal-on-metal bearings can be associated with increased wear, adverse tissue reactions and higher rate of implant loosening. Ceramic wear couples are a commonly used alternative to metals and therefore might be an alternative for hip resurfacing arthroplastys. The aim of this study was to evaluate the mechanical strength of femoral components made of an alumina-toughened zirconia composite by means of experimental testing and finite element analysis. For the mechanical characterization, ceramic femoral components (Ø: 48 mm) were tested under compression loading experimentally until fracture occurred or a maximum load of 85 kN was obtained. The femoral components were either loaded against a ceramic cup or a copper ring (outer diameter Ø: 7.0 mm). In addition, the complex geometry of the ceramic femoral component was simplified, and only the stem was loaded in a cantilever test until fracture. In addition, the fracture tests were numerically simulated to investigate the influence of additional loading conditions and geometric parameters, which were not experimentally tested. The experimental data were used for validation of the finite element analysis. None of the tested ceramic femoral components fractured at a compression load of 85 kN when they were loaded against a ceramic cup at an inclination angle of 45°. When the femoral components were loaded against a copper ring, the femoral components fractured at 29.9 kN at a testing angle of 45°. The fracture load was reduced when an angle of 30° and increased when an angle of 60° was simulated. Using an experimental cantilever test, the stem of the femoral component fractured at 1124.0 N. When the stem length was increased or the diameter was reduced by 10% in the finite element analysis, the fracture load was reduced. Decreasing the length or increasing the diameter led to an increase of the fracture load. The strongest influence was found for the reduction of the transition radius of the stem, with a decrease of the fracture load up to 27.2%. The analyzed femoral components made of alumina-toughened zirconia (ATZ) showed sufficient mechanical capability to withstand high loadings during unfavorable loading conditions. However, further biomechanical and tribological investigations are required before clinical application.

2008 ◽  
Vol 2008 ◽  
pp. 1-4
Author(s):  
Habiba Bougherara ◽  
Martin N. Bureau

Hip resurfacing technique is a conservative arthroplasty used in the young patient in which the femoral head is reshaped to accept metal cap with small guide stem. In the present investigation, a hybrid composite-metal resurfacing implant is proposed. The cup is made of carbon fiber/polyamide 12 (CF/PA12) covered with a thin layer of cobalt chrome (Co-Cr). Finite element (FE) method was applied to analyze and compare the biomechanical performances of the hybrid hip resurfacing (HHR) and the conventional Birmingham (BHR). Results of the finite element analysis showed that the composite implant leads to an increase in stresses in the cancellous bone by more than 15% than BHR, indicating a lower potential for stress shielding and bone fracture and higher potential for bone apposition with the HHR.


1985 ◽  
Vol 13 (3) ◽  
pp. 127-146 ◽  
Author(s):  
R. Prabhakaran

Abstract The finite element method, which is a numerical discretization technique for obtaining approximate solutions to complex physical problems, is accepted in many industries as the primary tool for structural analysis. Computer graphics is an essential ingredient of the finite element analysis process. The use of interactive graphics techniques for analysis of tires is discussed in this presentation. The features and capabilities of the program used for pre- and post-processing for finite element analysis at GenCorp are included.


2007 ◽  
Vol 35 (3) ◽  
pp. 226-238 ◽  
Author(s):  
K. M. Jeong ◽  
K. W. Kim ◽  
H. G. Beom ◽  
J. U. Park

Abstract The effects of variations in stiffness and geometry on the nonuniformity of tires are investigated by using the finite element analysis. In order to evaluate tire uniformity, a three-dimensional finite element model of the tire with imperfections is developed. This paper considers how imperfections, such as variations in stiffness or geometry and run-out, contribute to detrimental effects on tire nonuniformity. It is found that the radial force variation of a tire with imperfections depends strongly on the geometrical variations of the tire.


2018 ◽  
Vol 55 (4) ◽  
pp. 666-675
Author(s):  
Mihaela Tanase ◽  
Dan Florin Nitoi ◽  
Marina Melescanu Imre ◽  
Dorin Ionescu ◽  
Laura Raducu ◽  
...  

The purpose of this study was to determinate , using the Finite Element Analysis Method, the mechanical stress in a solid body , temporary molar restored with the self-curing GC material. The originality of our study consisted in using an accurate structural model and applying a concentrated force and a uniformly distributed pressure. Molar structure was meshed in a Solid Type 45 and the output data were obtained using the ANSYS software. The practical predictions can be made about the behavior of different restorations materials.


2013 ◽  
Vol 83 (7) ◽  
pp. 1087-1096 ◽  
Author(s):  
A. Ranjbaran ◽  
H. Rousta ◽  
M. O. Ranjbaran ◽  
M. A. Ranjbaran ◽  
M. Hashemi ◽  
...  

2012 ◽  
Vol 24 (3) ◽  
pp. 326-333 ◽  
Author(s):  
Yu-Chi Chen ◽  
Wen-Ching Ko ◽  
Han-Lung Chen ◽  
Hsu-Ching Liao ◽  
Wen-Jong Wu ◽  
...  

We propose a model to give us a method to investigate the characteristic three-dimensional directivity in an arbitrarily configured flexible electret-based loudspeaker. In recent years, novel electret loudspeakers have attracted much interest due to their being lightweight, paper thin, and possessing excellent mid- to high-frequency responses. Increasing or decreasing the directivity of an electret loudspeaker makes it excellent for adoption to many applications, especially for directing sound to a particular area or specific audio location. Herein, we detail a novel electret loudspeaker that possesses various directivities and is based on various structures of spacers instead of having to use multichannel amplifiers and a complicated digital control system. In order to study the directivity of an electret loudspeaker based on an array structure which can be adopted for various applications, the horizontal and vertical polar directivity characteristics as a function of frequency were simulated by a finite-element analysis model. To validate the finite-element analysis model, the beam pattern of the electret loudspeaker was measured in an anechoic room. Both the simulated and experimental results are detailed in this article to validate the various assertions related to the directivity of electret cell-based smart speakers.


Sign in / Sign up

Export Citation Format

Share Document