scholarly journals Restoration of Talar Height using a Modular Revision Prosthesis after Failed Total Ankle Arthroplasty

2019 ◽  
Vol 4 (2) ◽  
pp. 2473011419S0000
Author(s):  
Brian Steginsky ◽  
Steven L. Haddad

Category: Ankle Introduction/Purpose: Talar component subsidence is the most common indication for revision total ankle replacement. The management of talar bone loss and alteration in the ankle joint center of rotation is challenging following component subsidence. Unfortunately, ankle arthrodesis as a salvage procedure for failed ankle arthroplasty has been associated with high rates of nonunion and collapse. Equally unfortunate, there is paucity in the literature on revision total ankle arthroplasty. The purpose of this study was to report the early outcomes of revision total ankle replacement using a modular prosthesis and metal/cement augmentation to reconstitute talar height following catastrophic failure of the index total ankle arthroplasty. Methods: Retrospective review was performed on sixteen patients who underwent revision total ankle replacement for failed arthroplasty associated with talar component subsidence and subsequent talar bone loss. All patients underwent revision arthroplasty using a revision modular ankle prosthesis and had a minimum of one-year follow-up. Demographic data, postoperative complications, original prosthesis, and concomitant procedures were recorded. Radiographic measurements were performed at three time-points (preoperative, immediately after surgery, and at most recent follow-up) to evaluate alignment of the prosthesis, talar height, and ankle range of motion. Implant survivorship was determined. Failure was defined as >2 mm of talar subsidence, conversion to ankle arthrodesis or below the knee amputation, and/or revision of the prosthesis. Ankle Osteoarthritis Score (AOS), Foot Function Index (FFI), and visual analog score (VAS) were collected at the most recent postoperative visit. Results: Patient follow-up ranged from 12.1 –20.6 months, with a mean follow-up of 15.0 months. The mean preoperative and immediate postoperative talar height was 28.7 mm and 33.4 mm, respectively. There was a significant improvement in talar height of 4.7 mm after revision total ankle replacement (P<0.001). Talar height was maintained at most recent follow-up. The mean preoperative and postoperative radiographic arc of motion was 19.5° and 24.0°, respectively. Two patients, with a mean BMI of 43.5, developed >2 mm of talar subsidence (one patient required revision surgery). The mean postoperative AOS and FFI was 25.0 and 28.8, respectively. The majority of patients (84%) were satisfied with their outcome, and all patients would choose to undergo the same procedure again (vs. arthrodesis or amputation). Conclusion: Revision ankle replacement using a modular prosthesis with metal/cement augmentation allows restoration of talar height. Though we recognize this data constitutes a very early follow up, this cohort has utilized the revision ankle implant with significant repetitive load after which older generation implants underwent secondary subsidence due to poor talar bone stock. Early outcomes demonstrate a predictable method to salvage catastrophic prosthesis failure associated with severe talar subsidence and deformity. The risk of postoperative complications, although moderate, is an acceptable alternative to lower limb amputation/arthrodesis. Further follow-up is warranted to determine functional outcomes and longevity of revision implant systems.

2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0011
Author(s):  
Brian Steginsky ◽  
Steven Haddad

Category: Ankle Arthritis Introduction/Purpose: Talar component subsidence is the most common indication for revision total ankle replacement. The management of talar bone loss and alteration in the ankle joint center of rotation is challenging following component subsidence. Unfortunately, ankle arthrodesis as a salvage procedure for failed ankle arthroplasty has been associated with high rates of nonunion and collapse. Equally unfortunate, there is paucity in the literature on revision total ankle arthroplasty. The purpose of this study was to report the early outcomes of revision total ankle replacement using a modular prosthesis and metal/cement augmentation to reconstitute talar height following catastrophic failure of the index total ankle arthroplasty. Methods: A retrospective review was performed on sixteen patients who underwent revision total ankle replacement for failed arthroplasty associated with talar component subsidence and subsequent talar bone loss. Demographic data, postoperative complications, index implant, and concomitant procedures were recorded. Radiographic measurements were performed at three time-points (preoperative, immediately postoperative, and most recent follow-up) to evaluate alignment of the prosthesis, talar height restoration, and range of motion. Results: Patient follow-up ranged from 9.3 –19.1 months, with a mean follow-up period of 12.2 months. The maximum preoperative and postoperative talar coronal misalignment was 16.2° and 3.5°, respectively. The mean preoperative and immediate postoperative talar height was 28.7 mm and 33.3 mm, respectively. There was a significant improvement in talar height of 4.6 mm after revision total ankle replacement (P<0.001). There was no difference in talar height between the immediate postoperative visit and latest follow-up visit (33.2 mm). The mean preoperative and postoperative radiographic arc of motion was 19.5° and 24.0°, respectively. Ten patients (62.5%) did not sustain complications post surgical. Three patients developed a superficial wound complication that healed without additional surgery. One patient required a transmetatarsal amputation. Other complications included neuritis and DVT. Conclusion: Revision ankle replacement using a modular prosthesis with metal/cement augmentation allows restoration of talar height. Though we recognize this data constitutes a very early follow up, this cohort has utilized the revision ankle implant with significant repetitive load after which older generation implants underwent secondary subsidence due to poor talar bone stock. Early outcomes demonstrate a predictable method to salvage catastrophic prosthesis failure associated with severe talar subsidence and deformity. The risk of postoperative complications, although moderate, is an acceptable alternative to lower limb amputation/arthrodesis. Further follow up is warranted to determine functional outcomes and longevity of revision implant systems.


2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0042
Author(s):  
Hatem Salem-Saqer ◽  
Martin Raglan ◽  
Sunil Dhar

Category: Ankle; Ankle Arthritis Introduction/Purpose: Total ankle arthroplasty (TAA) is increasingly used for treatment of end stage arthritis of the ankle; improvements continue to evolve in implant design and instrumentation. We present our experience of the Infinity Total Ankle Arthroplasty (Wright Medical), a fixed bearing 4th generation implant with improved instrumentation Methods: This is a retrospective review of prospectively collected data. From October 2016 to July 2019, we identified 92 (52M/40F) who had the infinity Total Ankle Replacement. This review is of 70 patients with a minimum of 1 year follow up (33M,37F). The mean age was 67.5 years (33-87); 32 right side and 38 left no bilaterals. The indication for surgery was end stage Osteoarthritis in 52, post traumatic arthritis 12, inflammatory arthritis 4, conversion of fusion to TAR 2. The preoperative deformity was graded according to the COFAS classification. All patients had follow up at 6 weeks, 3,6 and 12 months and then annually, with MOXFQ questionnaire and weight bearing radiographs. Results: TAA was performed with the use of fluoroscopy. 77% (54/70) had concomitant procedures as listed in Table.5% (4/70) had complications consisting of, 1 DVT, 1 intra operative medial malleolus fracture, 1 EHL tendon laceration and 1 wound break down. There were no deep or superficial infections. Improvement in clinical outcome and PROMS data was noted on follow up. The MOXFQ for Pain improved from 72 pre-op to 25 at 1year (p<0.001). The outcome for Walking improved from 83 pre-op to 30 at one year (p<0.001). Radiological alignment was maintained asymptomatic posterior heterotopic ossification was noted in 23(16%) patients, lucent lines under the tibial implant were noted in 4 ankles and 1 fibula erosion. 2 TAA (3%) needed to be revised due to malpositioning. Conclusion: Our results show significant improvement in patient outcomes, a short recovery time and marked improvement in mobility post operatively with a very low complication rate, we had no deep infection to date. Two implants were revised which we attribute to the learning curve at the start of practice. This implant is fluoroscopically navigated allowing precise implantation with dedicated instrumentation and we feel this attributed to the low complication rate and good results in our short-term study [Table: see text]


2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0005
Author(s):  
Francesco Granata ◽  
Camilla Maccario ◽  
Luigi Manzi ◽  
Eric Tan ◽  
Federico Giuseppe Usuelli

Category: Ankle Arthritis Introduction/Purpose: Ankle arthritis is a highly limiting pathology that causes pain and functional limitation with subsequent deterioration of quality of life. With recent advances in surgical instrumentation and techniques, prosthetic replacement of the ankle has proved to be a valid alternative to arthrodesis with comparable outcomes. The purpose of this study was to evaluate clinical and radiological findings in a transfibular total ankle replacement with two years follow-up. Methods: This prospective study included 59 patients who underwent transfibular total ankle arthroplasty from May 2013 to December 2015. The mean age was 51.6 ± 13.4 years. All patients were followed for at least 24 months postoperative with an average follow-up of 42.0 ± 23.5 months. Patients were assessed clinically and radiologically preoperatively and at 6, 12, and 24 months postoperatively. Results: At 24 months, patients demonstrated statistically significant improvement in the American Orthopaedic Foot and Ankle Society score from 33.6 to 88.1 (P<0.01), VAS scale from 79.3 to 14.0 (P<0.01) and SF-12 Physical and Mental Composite Scores from 29.9 and 44.6 to 74.4 and 95.3, respectively (P<0.01). Ankle dorsiflexion and plantarflexion improved from 5.5 and 8.8 degrees to 24.2 and 20.0 degrees, respectively (P<0.01). Radiographically, patients demonstrated neutral alignment of the ankle with a tibio-talar ratio of 34.9 ± 9.2 and hindfoot alignment view angle of 1.2 ± 7.0 degrees. No patient demonstrated any radiographic evidence of tibial or talar lucency at 24 months. Seven patients underwent reoperation for removal of symptomatic hardware; one patient developed a postoperative prosthetic infection requiring placement of an antibiotic spacer. Conclusion: This study demonstrates that transfibular total ankle replacement is a safe and effective option for the patients for ankle arthritis with improvements in patient-reported outcomes, range of motion, and radiological parameters. However, further studies are required to determine the mid- and long-term performance of these implants.


2018 ◽  
Vol 40 (1) ◽  
pp. 24-33 ◽  
Author(s):  
Federico G. Usuelli ◽  
Camilla Maccario ◽  
Francesco Granata ◽  
Cristian Indino ◽  
Venus Vakhshori ◽  
...  

Background: Ankle arthritis is a highly limiting pathology that causes pain and functional limitation with subsequent deterioration of quality of life. With recent advances in surgical instrumentation and techniques, prosthetic replacement of the ankle has proven to be a valid alternative to arthrodesis with comparable outcomes. The purpose of this study was to evaluate clinical and radiological findings in a transfibular total ankle replacement with follow-up of at least 2 years. Methods: This prospective study included 89 patients who underwent transfibular total ankle arthroplasty from May 2013 to February 2016. The mean age was 53.2 ± 13.5 years. All patients were followed for at least 24 months postoperatively with an average follow-up of 42.0 ± 23.5 months. Patients were assessed clinically and radiographically preoperatively and at 6, 12, and 24 months postoperatively. Results: At 24 months postoperatively, patients demonstrated statistically significant improvement in the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle Hindfoot Score from 33.8 ± 14.3 to 88.5 ± 6.6 ( P < .001), visual analog scale (VAS) from 80.5 ± 17.0 to 14.1 ± 9.2 ( P < .001), and Short Form-12 Physical and Mental Composite Scores from 29.9 ± 6.7 and 43.3 ± 8.6 to 47.0 ± 7.6 and 53.3 ± 8.1, respectively ( P < .001). In addition, ankle dorsiflexion and plantarflexion improved from 6.2 ± 5.5 and 9.6 ± 5.8 degrees to 24.2 ± 7.9 and 18.1 ± 7.6 degrees, respectively ( P < .001). Radiographically, patients demonstrated maintained neutral alignment of the ankle at 24 months. No patient demonstrated any radiographic evidence of tibial or talar lucency at final follow-up. Seven patients underwent reoperation for removal of symptomatic hardware (6 fibular plates, 1 syndesmotic screw); 2 patients experienced delayed wound healing. The first one was treated with plate removal and flap coverage. The second one required fibular plate removal. One patient developed a postoperative prosthetic infection requiring operative debridement, removal of implants, and placement of an antibiotic spacer. Conclusion: This study found that transfibular total ankle replacement was a safe and effective option for patients with ankle arthritis resulting in improvements in patient-reported outcomes, range of motion, and radiographic parameters. However, further studies are required to determine the mid- and long-term performance of these implants. Level of Evidence: Level IV, case series.


2017 ◽  
Vol 2 (2) ◽  
pp. 2473011416S0000
Author(s):  
Taylor Den Hartog ◽  
Samuel Carlson ◽  
Greg Alvine ◽  
Frank Alvine ◽  
Bryan Den Hartog ◽  
...  

Category: Ankle Arthritis Introduction/Purpose: With the introduction of newer generations of total ankle arthroplasty (TAA) constructs, the incidence of TAA in the United States has been increasing. While TAA has emerged as an alternative to ankle arthrodesis for the management of end-stage ankle arthritis, long-term data evaluating clinical outcomes and the survivorship of ankle prostheses is lacking. The purpose of this study was to report the clinical outcomes and radiographic survivorship of a second-generation, semi-constrained titanium and cobalt-chromium total ankle prosthesis at minimum twenty-year follow-up in order to provide a benchmark comparison for future generations of TAA design. Methods: 132 total ankle replacements in 126 patients were performed by a single surgeon between July 1984 and October 1994. Follow-up evaluation consisted of determining revision status, completion of the validated ankle osteoarthritis scale, a short questionnaire, and a review of the available radiographs. All radiographs were evaluated for evidence of progressive radiolucent lines, osteolysis and component subsidence. Results: At minimum twenty-year follow-up, 37 patients were alive, 89 were deceased, and 5 were lost to follow-up. For living patients, average clinical follow up was 25.3 years. Average radiographic follow-up was 21.4 years. Over the minimum 20 year follow-up, 29 ankles were revised (23%). For living patients, 13 ankles were revised (35%). Conclusion: Twenty-three percent of all patients and 35% of living patients required a revision over the minimum 20 year follow up interval. 65% of living patients have retained their prosthesis and 75% of the entire cohort are still functioning with their original ankle replacement or died with the original ankle replacement in place. This study should provide a benchmark for newer designs when they obtain this length of follow-up.


2020 ◽  
Vol 41 (8) ◽  
pp. 937-944
Author(s):  
Jungtae Ahn ◽  
Myung Chul Yoo ◽  
Jeunghwan Seo ◽  
Moonsu Park ◽  
Bi O Jeong

Background: Total ankle arthroplasty (TAA) can result in excellent outcomes in patients with end-stage arthritis, but most patients with end-stage hemophilic ankle arthropathy (ESHAA) still undergo ankle arthrodesis (AA). The purpose of this study was to analyze clinical and radiological results of TAA and AA for ESHAA. Methods: A total of 29 cases (16 TAAs and 13 AAs) of painful ESHAA were included. For clinical outcome evaluation, visual analog scale (VAS) for pain, Foot Function Index (FFI), and range of motion (ROM) were analyzed. Postoperative clinical and radiological complications were also analyzed. The mean duration of follow-up was 6.8 ± 3.0 years. The mean age was 44.1 ± 9.9 years. Results: The VAS for pain was significantly improved from 5.5 ± 2.3 to 0.9 ± 1.2 ( P < .001). The FFI scale was significantly improved from 61.6% ± 15.5% to 16.6% ± 15.4% ( P < .001). In FFI disability and activity subscales, the TAA group exhibited meaningful outcomes relative to those of the AA group ( P = .012 and .036, respectively). The total ROM in the TAA group changed from 30.8 ± 12.6 degrees to 37.3 ± 12.8 degrees at final follow-up ( P = .090). Three cases of osteolysis and 1 case of heterotopic ossification were noted in the TAA group. No cases of nonunion were noted in the AA group. Progressive arthrosis of adjacent joints after AA was observed in 1 case. Conclusion: Both TAA and AA in ESHAA exhibited significant improvement in pain based on VAS and FFI scales. Compared to AA, TAA resulted in superior outcomes in FFI disability and activity subscales, suggesting that TAA may be considered as a surgical option alongside AA for ESHAA. Level of Evidence: Level III, retrospective comparative study.


2021 ◽  
pp. 193864002098092
Author(s):  
Devon W. Consul ◽  
Anson Chu ◽  
Travis M. Langan ◽  
Christopher F. Hyer ◽  
Gregory Berlet

Total ankle replacement has become a viable alternative to ankle arthrodesis in the surgical management of advanced ankle arthritis. Total ankle replacement has generally been reserved for patients who are older and for those who will have a lower demand on the replacement. The purpose of the current study is to review patient outcomes, complications, and implant survival in patients younger than 55 years who underwent total ankle replacement at a single institution. A single-center chart and radiographic review was performed of consecutive patients who underwent total ankle replacement for treatment of end-stage ankle arthritis. All surgeries were performed by 1 of 5 fellowship-trained foot and ankle surgeons at a single institution. A total of 51 patients met inclusion criteria with a mean follow-up of 31.2 months (SD = 16.2). Implant survival was 94%, There were 7 major complications (13%) requiring an unplanned return to the operating room and 8 minor complications (15%) that resolved with conservative care. The results of this study show that total ankle replacement is a viable treatment option for patients younger than 55 years. Levels of Evidence: A retrospective case series


2019 ◽  
Vol 4 (4) ◽  
pp. 2473011419S0028
Author(s):  
Karim Mahmoud ◽  
Sreenivasulu Metikala ◽  
Kathryn O’Connor ◽  
Daniel Farber

Category: Ankle Arthritis Introduction/Purpose: Total ankle replacement has become a popular treatment option for end stage ankle arthritis. Most of the reports of adverse events following total ankle replacement have been from high volume institutions and are subject to either observational or selection bias as well as potential under-reporting as they do not include the experience of community and lower volume centers and surgeons. The FDA’s Medical and User Facility Device Experience (MAUDE) Database provides a more complete scope of adverse events due to the mandatory reporting requirements by the FDA of implant manufactures. We reviewed the database to identify the common modes of failure and complications of total ankle implants Methods: We retrospectively reviewed reports of the MAUDE database from November 2011 to September 2018 regarding all total ankle implants. Each device in the MAUDE database is classified with a 3-letter code, we identified the 2 codes assigned to total ankle arthroplasty devices, and manually searched the FDA’s published Device Classification list for adverse events. All events were reviewed and classified. Data related to patient age or sex, surgeon, medical center location are not available in the database Results: We identified 1000 adverse reports in the period between November 2011 and September 2018. After exclusion of duplicate reports for single events or reports irrelevant to total ankle arthroplasty, a total of 697 adverse event reports were noted. The most common mode of failure was aseptic loosening (21%), followed by infection (16%), alignment and mechanical issues (instability, malalignment, malposition, stiffness, impingement) (15%), implantation issues (pin, screw or drill breakage, alignment guide problems) (9%), polyethylene related problems (wear, displaced or fractured implants) (7%), bony and soft tissue overgrowth (6%), and peri-prosthetic fractures (5%). Conclusion: Our analysis reveals that the most reported mode of failure was aseptic loosening followed by infection. However, it is notable that there are a significant number of issues with implant alignment and mechanics, complications during implantation and polyethylene component failure that are under-reported in the literature. Knowledge of these adverse events may help surgeons avoid similar complications as well as lead to improvement in component implantation and design


2020 ◽  
Vol 5 (4) ◽  
pp. 2473011420S0032
Author(s):  
Hong S. Lee ◽  
Kiwon Young ◽  
Tae-Hoon Park ◽  
Hong Seop Lee

Category: Ankle Introduction/Purpose: Failed total ankle arthroplasty (TAA) often results in significant bone loss and requires salvage arthrodesis. The aim of this study was to investigate the outcomes of Salvage arthrodesis with allo-bone block for failed TAA. Methods: This study included 8 patients who underwent salvage arthrodesis with femoral head allograft for failed TAA from August 2012 to March 2018 because of loosing of TAA implant. The mean age of the patients was 71 years (range, 54-81 years), and the mean follow-up period was 32 months (range, 12 to 84 months). Allograft problem and alignment of joint were evaluated radiographically. American Orthopaedic Foot & Ankle Society (AOFAS) scores, Foot and Ankle Outcome Score (FAOS), and visual analogue scale (VAS) pain scores were recorded preoperatively and at the time of final followup. Functional questionnaires were used to assess the duration for which the patient could walk continuously, use of walking aids, consumption of pain medication, and the patient’s subjective assessment of the percentage of overall improvement compared with before the salvage arthrodesis. Results: The allograft was retained without collapse for a mean of 24 months (range, 12 to 36 months) in four patients. Collapse of the allograft was observed in four patients at a mean of 11 months (range, 9 to 16 months), 1 of 4 patients were conserved to retrograde intramedullary nail at postoperative 12 months because of with implant failure and nonunion. The mean AOFAS and VAS pain scores improved from 12 (range, 8 to 40) preoperatively to 63 (range, 38 to 75) postoperatively (p = 0.001) and from 7 (range, 6 to 10 to 3 (range, 2 to 8) (p = 0.001), respectively. At the final follow-up evaluation, 6 of 8 patients were able to walk continuously at least 30 minutes with walking aid. Conclusion: The successful rate of salvage arthrodesis with femoral head allograft was 75% (Six of total 8 patients). The incidence rate of allograft collapse was 50% (Four of total 8 patients).


2018 ◽  
Vol 3 (3) ◽  
pp. 2473011418S0051
Author(s):  
Stephen White ◽  
Bruce Cohen ◽  
Carroll Jones ◽  
Michael Le ◽  
W. Hodges Davis

Category: Ankle Arthritis Introduction/Purpose: Ankle arthrodesis remains a prominent treatment choice for ankle arthritis in a majority of patients. Long term studies have shown a compensatory development of ipsilateral adjacent joint arthritis after ankle arthrodesis, and some patients who receive an ankle arthrodesis develop pain in surrounding joints, or even at the fusion site. As total ankle arthroplasty (TAA) design, instrumentation, and techniques have improved, the use of total ankle arthroplasty has become more widespread. Very few studies have been published on conversion of ankle arthrodesis to ankle arthroplasty, but they have shown improved function and patient-related outcome scores. The purpose of this study was to assess the radiographic, clinical, and patient-reported outcomes of patients undergoing ankle arthroplasty after conversion from a CT-confirmed ankle arthrodesis. Methods: This was a retrospective cohort study of patients with previous CT-confirmed ankle arthrodesis who underwent conversion to total ankle arthroplasty. Minimum follow up was 1 year. Nonunions of ankle arthrodesis were excluded. AOFAS ankle-hindfoot score, foot function index (FFI), pain, revision surgeries, complications, and patient demographics were assessed. Radiographs prior to TAA, and at latest follow-up were also reviewed. Results: 10 patients were included in the study with an average age of 54.5 years. No implants had to be revised. 1/10 (10%) patients had to undergo secondary surgery for heterotopic ossification removal. The same patient had to undergo another subsequent surgery for posterior ankle decompression. 2/10 (20%) patients had a mild talar subsidence of the TAA at latest follow-up, with no patients having tibial subsidence. Talar osteolysis was noticed in 2 patients (20%) at latest follow-up, with no patients having tibial osteolysis. Only one patient (10%) was noted to have a mild valgus alignment of TAA with no varus malalignments. All radiographic changes noted were clinically asymptomatic. The average AOFAS total score was 58 (range 23,89). The mean FFI total score was 41.9 (range 0,90). Conclusion: Conversion of ankle fusion to TAA is a challenging operation but can be a viable option for patients with ongoing pain after an ankle arthrodesis. We noted low revision rates and few complications at 1 year.


Sign in / Sign up

Export Citation Format

Share Document