Sonographic Diagnosis of a Mature Cystic Teratoma Resulting in Acute Torsion

2020 ◽  
Vol 36 (3) ◽  
pp. 267-271
Author(s):  
Amber Sales

Mature cystic teratomas are benign germ cell tumors and, depending on the size, may be at risk for torsion. These ovarian masses can cause the ovarian vasculature to twist upon itself and inhibit blood flow, resulting in partial to complete torsion. If detection and treatment are not prompt, a salpingo-oophorectomy may be needed impeding future fertility. This case describes a young woman with acute left adnexal pain where sonography aided in the diagnosis of ovarian torsion caused by a large mature cystic teratoma. Transabdominal sonography was used, aided by extended field-of-view technology for characterization of the mass. The sonographic attributes of mature cystic teratomas vary, but careful evaluations can lead to an accurate diagnosis to aid in surgical procedures. The patient underwent an exploratory laparotomy, which resulted in a left ovary oophorectomy and excision of the mass.

2021 ◽  
Author(s):  
Gabriel Paiva Fonseca ◽  
Matthias Baer‐Beck ◽  
Eric Fournie ◽  
Christian Hofmann ◽  
Ilaria Rinaldi ◽  
...  

2007 ◽  
Author(s):  
Holger Kunze ◽  
Wolfgang Härer ◽  
Karl Stierstorfer

2008 ◽  
Vol 190 (1) ◽  
pp. 27-31 ◽  
Author(s):  
Eoin C. Kavanagh ◽  
George Koulouris ◽  
Laurence Parker ◽  
William B. Morrison ◽  
Diane Bergin ◽  
...  

2016 ◽  
Vol 7 (2) ◽  
pp. 512 ◽  
Author(s):  
F. Momey ◽  
J.-G. Coutard ◽  
T. Bordy ◽  
F. Navarro ◽  
M. Menneteau ◽  
...  

2020 ◽  
Vol 22 (2) ◽  
pp. 152 ◽  
Author(s):  
Chrysostomos Sahinis ◽  
Eleftherios Kellis ◽  
Nikiforos Galanis ◽  
Konstantinos Dafkou ◽  
Athanasios Ellinoudis

Aim: Τo examine the inter- and intra-muscular differences in the anatomical cross-sectional area (CSA) of the quadricep muscles, using extended - field of view (EFOV) ultrasonography (US).Material and methods: Panoramic transverse US images of the thigh were acquired from 10 young participants at five different locations across the thigh, in two sessions, spaced a week apart. The CSA of the vastus medialis (VM), rectus femoris (RF), vastus intermedius (VI), vastus lateralis (VL) and tensor vastus intermedius (TVI) was quantified.Results: The intraclass correlation coefficients ranged from 0.75 to 0.97 and the standard error of measurement ranged from 0.78% to 6.61%, indicating high test-retest reliability. Analysis of the variance indicated that among the 5 quadriceps muscles the VL and the RF displayed the greater CSA proximally, the VI medially and the VM distally across the thigh (p <0.05). No differences in the quadriceps CSA measured with and without including the TVI were found (p >0.05).Conclusions: The EFOV US technique provides transverse scans of the quadriceps muscle in vivo and allowed a reliable and non-invasive determination of CSA at a low cost. Evaluation of CSA along the thigh largely depends on the measurement site. Future studies that examine the quadriceps CSA using EFOV after any form of intervention should consider changes of at least 6.5% as meaningful.


Author(s):  
Borislava Petrovic ◽  
Dario Faj ◽  
Mladen Markovic ◽  
Arpad Tot ◽  
Milana Marjanovic ◽  
...  

The purpose of this work was to evaluate computed tomography (CT) simulators used in radiotherapy treatment planning in Serbia, Croatia and Bosnia and Herzegovina. A survey of quality assurance programmes of 24 CT simulators in 16 facilities was conducted. Dedicated CT-to-ED phantom was scanned at 120 kV and 140 kV, to obtain CT-to-ED (ED- Electron Density) conversion curves as well as CTDIvol. Thoracal phantoms were scanned in standard and extended field of view to evaluate dosimetric effect on treatment planning and delivery. Mean age of measured scanners was 5.5 years. The mean water HU value was -6.5 (all scanners, all voltages) and air HU value was -997. Extended field of view CT data differ from standard field of view and differences between conversion curves have significant dosimetric impact. The CTDI data showed large range of values between centers. Better QA of CT simulators in all countries is recommended. CT-to-ED curve could be used as default at one voltage and per manufacturer. Extended field of view imaging can be used, but treatment planning should be avoided in the regions out of standard field of view.


Sign in / Sign up

Export Citation Format

Share Document