scholarly journals Lens-induced hypopyon uveitis as the presenting manifestation of posterior lens nucleus dislocation following pars-plana vitrectomy: case report

Author(s):  
Ksiaa Imen ◽  
Ben Hadj Tahar Meriam ◽  
Sellem Ilhem ◽  
Attia Sonia ◽  
Abroug Nesrine ◽  
...  

AbstractA 57-year-old otherwise healthy male presented to our department seven days following uneventful pars-plana vitrectomy with gas tamponade for a superior bullous retinal detachment in the left eye. Ophthalmic examination revealed anterior segment inflammation with hypopyon and fibrinous exudate. Intra-ocular pressure was 28 mmHg. Posterior segment evaluation was difficult to assess due to the presence of anterior capsule opacification and gas bubble. A Toxic Anterior Segment Syndrome was suspected, and the patient was treated with topical and oral corticosteroid medication in combination with anti-glaucomatous therapy. On follow-up, anterior segment inflammation and ocular hypertension improved. On day ten post-operatively, ocular ultrasonography demonstrated lens material inferiorly with attached retina. The final diagnosis of posterior lens nucleus dislocation with lens-induced uveitis was retained. The patient underwent an uneventful second vitrectomy with aspiration of the dislocated lens nucleus and sulcus three piece-lens implantation. On last follow-up, visual acuity was 20/50 with no relapsing of ocular inflammation and the retina remained reattached.

2021 ◽  
Author(s):  
Imen Ksiaa ◽  
Meriam Ben Hadj Tahar ◽  
Ilhem Sellem ◽  
Sonia Attia ◽  
Nesrine Abroug ◽  
...  

Abstract A 57-year-old otherwise healthy male presented to our department seven days following uneventful pars-plana vitrectomy with gas tamponade for a superior bullous retinal detachment in the left eye. Ophthalmic examination revealed anterior segment inflammation with hypopyon and fibrinous exudate. Intra-ocular pressure was 28 mm Hg. Posterior segment evaluation was difficult to assess due to the presence of anterior capsule opacification and gas bubble. A Toxic Anterior Segment Syndrome was suspected and the patient was treated with topical and oral steroid medication associated with anti-glaucomatous therapy. On follow-up, anterior segment inflammation and ocular hypertension improved. On day ten post-operatively, ocular ultrasonography demonstrated lens material inferiorly with attached retina. The final diagnosis of posterior lens nucleus dislocation with lens-material antigenic uveitis was retained. The patient underwent an uneventful second vitrectomy with aspiration of the dislocated lens nucleus and sulcus three piece-lens implantation. On last follow-up, visual acuity was 20/50 with no relapsing of ocular inflammation and the retina remained reattached.


2018 ◽  
Vol 29 (6) ◽  
pp. 689-693
Author(s):  
Miklós D Resch ◽  
Anikó Balogh ◽  
Gábor L Sándor ◽  
Zsuzsanna Géhl ◽  
Zoltán Zsolt Nagy

Introduction: Vitrectorhexis is an alternative for manual continuous curvilinear capsulorhexis originally developed for paediatric cataract surgery. The aim of our study was the evaluation of the technique in adult patients with penetrating ocular injury and traumatic cataracts. Methods: Eight eyes of 8 patients (23–41 years, all males) had penetrating mechanical corneal trauma. Anterior lens capsule was penetrated in all cases and additional posterior capsule defect in five cases. Intraocular foreign body was detected in one case in the crystalline lens and in two cases in the posterior segment. Standard 23G infusion cannula and vitreous cutter were applied to perform anterior capsule opening, removal of lens material, anterior vitrectomy and pars plana vitrectomy if needed. No phacoemulsification or irrigation/aspiration probe was used. Results: Vitrectorhexis could be performed in 7 out of 8 cases with the preservation of peripheral anterior capsule; primary implantation of posterior chamber intraocular lens was possible in all cases (in the bag in three eyes and into the sulcus in five eyes). Anterior chamber was stable in all cases intraoperatively, and no dropped nucleus or lens fragment loss was observed. Surgery was combined with pars plana vitrectomy in three cases, with foreign body removal (when necessary). No postoperative complication occurred. Conclusion: Vitrectorhexis was found to be an effective and safe alternative method in the management of complex anterior segment trauma cases. With its use, traditional cataract surgical devices can be substituted and additional benefits of vitreous cutter can be utilized in selected cases, especially in young adults.


Author(s):  
Tomasz K. Wilczyński ◽  
Alfred Niewiem ◽  
Rafał Leszczyński ◽  
Katarzyna Michalska-Małecka

A 36-year-old patient presented to the hospital with recurrent dislocation of the intraocular lens (IOL). The patient with the diagnosis of familial ectopia lentis was first operated on for crystalline lens subluxation in the left eye in 2007 and in the right eye in 2009. In both eyes, lens extraction with anterior vitrectomy and transscleral fixation of a rigid IOL was performed. In 2011, the IOL in the right eye luxated into the vitreous cavity due to ocular trauma. The patient underwent a pars plana vitrectomy with the IOL resuturation to the sclera. Seven years later, a spontaneous vision loss in the right eye was caused by a retinal detachment. The pars plana vitrectomy with silicone oil tamponade and a consequential oil removal three months later were performed in 2018. The follow-up examination revealed recurrent IOL dislocation in the same eye. Due to a history of previous suture-related complications a decision was made to remove the subluxated rigid polymethyl-methacrylate (PMMA) IOL and fixate to sclera a sutureless SOLEKO FIL SSF Carlevale lens. The purpose of this report is to present a single case of a 36-year-old patient who was presented to the hospital with recurrent dislocation of the intraocular lens. In a three-month follow-up period, a good anatomical and functional outcome was finally obtained with transscleral sutureless intraocular lens. This lens is an option worth considering especially in a young patient with a long life expectancy and physically active.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Enchi Kristina Chang ◽  
Sanchay Gupta ◽  
Marika Chachanidze ◽  
John B. Miller ◽  
Ta Chen Chang ◽  
...  

Abstract Purpose The purpose of this study is to report the safety and efficacy of pars plana glaucoma drainage devices with pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement in patients with refractory glaucoma. Methods Retrospective case series of 28 eyes of 28 patients who underwent combined pars plana glaucoma drainage device and pars plana vitrectomy between November 2016 and September 2019 at Massachusetts Eye and Ear. Main outcome measures were intraocular pressure (IOP), glaucoma medication burden, best corrected visual acuity, and complications. Statistical tests were performed with R and included Kaplan-Meier analyses, Wilcoxon paired signed-rank tests, and Fisher tests. Results Mean IOP decreased from 22.8 mmHg to 11.8 mmHg at 1.5 years (p = 0.002), and mean medication burden decreased from 4.3 to 2.1 at 1.5 years (p = 0.004). Both IOP and medication burden were significantly lower at all follow-up time points. The probability of achieving 5 < IOP ≤ 18 mmHg with at least 20% IOP reduction from preoperative levels was 86.4% at 1 year and 59.8% at 1.5 years. At their last visit, three eyes (10.7%) achieved complete success with IOP reduction as above without medications, and 14 eyes (50.0%) achieved qualified success with medications. Hypotony was observed in 1 eye (3.6%) prior to 3 months postoperatively and 0 eyes after 3 months. Visual acuity was unchanged or improved in 23 eyes (82.1%) at their last follow-up. Two patients had a visual acuity decrease of > 2 lines. Two eyes required subsequent pars plana vitrectomies for tube obstruction, and one eye had transient hypotony. Conclusions The results of pars plana glaucoma drainage device and pars plana vitrectomy using one of the vitrectomy sclerotomy sites for tube placement are promising, resulting in significant IOP and medication-burden reductions through postoperative year 1.5 without additional risk of postoperative complications. Inserting glaucoma drainage devices into an existing vitrectomy sclerotomy site may potentially save surgical time by obviating the need to create another sclerotomy for tube placement and suture one of the vitrectomy ports.


Author(s):  
Alireza Khodabande ◽  
Massood Mohammadi ◽  
Hamid Riazi-Esfahani ◽  
Shahab Karami ◽  
Massood Mirghorbani ◽  
...  

Abstract Background To evaluate changes in anterior segment morphology on anterior segment optical coherence tomography (AS-OCT) following pars plana vitrectomy (PPV) without tamponade. Methods Patients who underwent PPV without tamponade for epiretinal membrane were evaluated. Eligible patients underwent intraocular pressure (IOP) measurement and AS-OCT preoperatively as well as 1 month and 6 months post-operatively. Anterior chamber width (ACW), anterior chamber depth (ACD), trabecular iris angle (TIA), angle opening distance at 500 and 750 µm (AOD), and trabecular iris space area at 500 and 750 µm (TISA) at four quadrants were recorded and analyzed. Additionally, the mean values of TIA (MTIA), AOD (MAOD), and TISA (MTISA) for each eye (mean of four quadrants) were analyzed. Results 23 patients completed the study. The mean age of participants was 56.4 ± 3.6 years of age and 13/23 (56%) were female. Mean IOP of patients was 18.1 ± 1.1, 18.3 ± 1.1, and 18.1 ± 1.2 preoperatively,1 month post-operatively, and 6 months post-operatively, respectively. (p = 0.83). No difference was detected post-operatively in measurements of ACW, ACD, MTIA, MAOD500, MAOD750, MTISA500, and MTISA750. Conclusion Pars plana vitrectomy without tamponade was not associated with changes in anterior chamber morphology.


2020 ◽  
Vol 237 (09) ◽  
pp. 1070-1078
Author(s):  
Antonia M. Joussen ◽  
Bert Müller ◽  
Bernd Kirchhof ◽  
Theodor Stappler ◽  
Oliver Zeitz

AbstractDue to their complexity, globe ruptures are highly compromising traumas for the patient. This is due on the one hand to the eye injury itself with the accompanying loss of vision and on the other hand due to the need for extended treatment with uncertain prognosis and the resulting psychological stress. Globe ruptures are among the prognostically most unfavorable injuries due to the force and peak pressure impacting the eye. Furthermore, contusional retinal necrosis may be of significance prognostically. In the present review, we discuss treatment of globe ruptures involving retinal surgery. We discuss the primary sugery, its chronological planning and extent as well as the necessity for follow-up interventions. We also discuss the origin of traumatic retinal detachment with differential diagnosis of giant retinal tear versus oradialysis as well as secondary sequelae of traumas such as formation of macular holes and their treatment. On this basis, the use of buckling surgery versus pars-plana vitrectomy is discussed. Further focus is set on the role of the iris lens diaphragm in surgery of globe ruptures.


2008 ◽  
Vol 39 (4) ◽  
pp. 319-322 ◽  
Author(s):  
Tom W. Harper ◽  
Harry W. Flynn ◽  
Audina Berrocal ◽  
John T. Thompson ◽  
Jean-Marie Parel

2020 ◽  
Vol 2020 ◽  
pp. 1-4
Author(s):  
A. Altun

Purpose. We aimed at reminding that X-linked retinoschisis may also be seen in female patients and share our vitreoretinal surgical experience. Methods. The patient underwent pars plana vitrectomy including the closure of the macular holes with inverted ILM flap technique bilaterally. Lens extractions were performed by phacoemulsification during the removal of silicone oil endotamponade. Patient. An 18-year-old girl with X-linked retinoschisis and large macular holes in both eyes presented to the clinic of ophthalmology. It was confirmed that the patient had RS1 mutation Results. Nine-month-follow-up was uneventful for retinal findings. Significant improvement in visual acuity was achieved, and macular holes were remained closed. Conclusion. In cases with large macular holes due to XLR, an inverted ILM flap technique might be safe and effective. Four-month-silicone-endotamponade might be sufficient.


Sign in / Sign up

Export Citation Format

Share Document