scholarly journals Midterm follow up of transcatheter closure of coronary artery fistula with Nit-Occlud® patent ductus arteriosus coil

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hamid Amoozgar ◽  
Mohammad Reza Edraki ◽  
Amir Naghshzan ◽  
Nima Mehdizadegan ◽  
Hamid Mohammadi ◽  
...  

Abstract Background Coronary artery fistula (CAF) is a rare congenital anomaly with a challenging scenario in children. This study reports our experience in transcatheter closure of CAF with Nit-Occlude PDA coil and midterm clinical and imaging follow-up. Methods Twelve children with congenital CAF between 2009 and 2019, mean age 2.05 ± 2.05 years (4 days to 7.2 years), mean weight 8.8 ± 4.83 (2.8–17 kg), who underwent transcatheter closure with PFM coil at the Namazi hospital, Shiraz, Iran, were reported. Echocardiography and electrocardiogram were done before and after the procedure (early, 3, and 6 months after), and Multi-slice computerized tomography or conventional coronary angiography was performed at least one year after closure. Results In a median follow-up of 5.5 years (range 13 months to 8 years), retrogradely closed fistula had no residual, and the fistula tract was wholly occluded, but in most anterogradely closed fistula, had a small residual, which made the fistula tract open and need additional coil closure. Conclusions Transcatheter closure of CAF with PFM coil is feasible and effective with low mortality and morbidity, although antegrade closure with this device may be accompanied by residual shunt and need for multiple coil insertion.

2015 ◽  
Vol 26 (5) ◽  
pp. 915-920 ◽  
Author(s):  
Gurleen K. Sharland ◽  
Laura Konta ◽  
Shakeel A. Qureshi

AbstractObjectivesThe aim of this study was to describe the clinical characteristics, progression, treatment, and outcomes in isolated coronary artery fistula cases diagnosed prenatally.MethodsWe carried out a retrospective review of babies diagnosed prenatally with coronary artery fistulas between January, 2000 and December, 2013; five fetuses were included. Echocardiographic features and measurements were noted during pregnancy and after birth. Treatment and outcome were noted.ResultsGestational age at initial diagnosis was between 19 and 22 weeks; four coronary artery fistulas originated from the right and one from the left circumflex coronary artery. Drainage was into the right atrium in four cases and into the left ventricle in one case. There was cardiomegaly in two cases at the initial scan. The size of the fistulas increased during pregnancy in all except one. All prenatal diagnoses were confirmed postnatally. Among all, two patients developed congestive cardiac failure soon after birth and required transcatheter closure of the coronary artery fistula, 5 and 17 days after birth, respectively; three patients remained asymptomatic, and all of them showed progressive dilation of the feeding artery and had closure of the fistula at 20 months, 4 years, and 7 years of age, respectively. During the follow-up period, which ranged 2–14 years, all the patients were alive and well.ConclusionsCoronary artery fistulas can be diagnosed accurately during fetal life. Some babies may develop congestive cardiac failure soon after birth requiring early treatment. Those treated conservatively should be kept under review as intervention may be required later.


2014 ◽  
Vol 25 (4) ◽  
pp. 670-680 ◽  
Author(s):  
Bhavesh Thakkar ◽  
Nehal Patel ◽  
Vishal Poptani ◽  
Tarun Madan ◽  
Tarandip Saluja ◽  
...  

AbstractBackground: Transcatheter closure of coronary artery fistula has emerged as a safe and effective alternative to surgery. However, follow-up angiographic data after closure of the coronary artery fistula is extremely limited. We report our clinical and angiographic follow-up of children who underwent either transcatheter or surgical closure. Method: Clinical profile, echocardiography parameters, and closure technique were retrospectively reviewed from the hospital charts. Since 2007, 15 children have been intervened and followed up with electrocardiography, echocardiography, and angiography. Results: A total of 15 children (six girls), with mean age of 6.7±5.4 years and weighing 16.3±9.8 kg, underwent successful closure (transcatheter=13, surgical=2) without periprocedural complication. Coronary artery fistula arose from the right (n=7) and left coronary artery (n=8) and drained into the right atrium or the right ventricle. Transcatheter closure was carried out using a duct occluder. Of the patients, two underwent surgical closure of the fistula on a beating heart. At 31.8±18.7 months follow-up, all the children were asymptomatic and had no evidence of myocardial ischaemia or infarction. However, follow-up angiography revealed thrombotic occlusion of fistula with the patent parent coronary artery in those having branch coronary artery fistula, and five of seven patients with parent coronary artery fistula had near-complete occlusion of fistula extending into the native coronary artery. Conclusion: Follow-up angiography revealed a high incidence of parent artery occlusion when the fistula was arising from the native artery and not from one of its branches. Coronary artery fistula intervention of the parent coronary artery fistula always carries the potential risk of ischaemia, unless the distal-most exiting segment is the primary site of occlusion.


Author(s):  
Achyut Sarkar ◽  
Neha Rani ◽  
Prashant Kumar ◽  
Shyam Sundar Chaudhary ◽  
Suman Chatterjee

Background: Patent Ductus Arteriosus (PDA) is a common congenital disorder. As an isolated lesion, PDA constitutes 6 to 11% of all congenital heart disease. PDA needs closure to eliminate pulmonary over circulation leading to volume overload of left ventricle, pulmonary vascular obstructed disease.Methods: This retrospective study was carried out in pediatric cardiology unit of Institute of Postgraduate Medical Education and Research, Kolkata from September 2005 to August 2016, which included 503 patients.Results: Device closure was attempted in 492 patient’s Procedural success was achieved in 85% cases on table, in who check aortogram revealed complete closure of PDA. In 15% cases, residual shunt was present. In 12% of cases, residual shunt disappeared during follow-up echocardiogram over 6-month follow-up. In 3% cases, small shunt remained at 6-month and 1-year follow up.Conclusion: Transcatheter closure of PDA by duct occluder is safe and effective with good mid-term outcome. The optimum assessment of ductul size and anatomy is crucial for optimum device size, which prevents residual shunt, device embolization and protrusion.


Author(s):  
Srinath T. Gowda ◽  
Larry Latson ◽  
Kothandam Sivakumar ◽  
Gurumurthy Hiremath ◽  
Matthew Crystal ◽  
...  

Background: Coronary artery fistulas (CAFs) presenting in infancy are rare, and data regarding postclosure sequelae and follow-up are limited. Methods: A retrospective review of all the neonates and infants (<1 year) was conducted from the CAF registry for CAF treatment. The CAF type (proximal or distal), size, treatment method, and follow-up angiography were reviewed to assess outcomes and coronary remodeling. Results: Forty-eight patients were included from 20 centers. Of these, 30 were proximal and 18 had distal CAF; 39 were large, 7 medium, and 2 had small CAF. The median age and weight was 0.16 years (0.01–1) and 4.2 kg (1.7–10.6). Heart failure was noted in 28 of 48 (58%) patients. Transcatheter closure was performed in 24, surgical closure in 18, and 6 were observed medically. Procedural success was 92% and 94 % for transcatheter closure and surgical closure, respectively. Follow-up data were obtained in 34 of 48 (70%) at a median of 2.9 (0.1–18) years. Angiography to assess remodeling was available in 20 of 48 (41%). I. Optimal remodeling (n=10, 7 proximal and 3 distal CAF). II. Suboptimal remodeling (n=7) included (A) symptomatic coronary thrombosis (n=2, distal CAF), (B) asymptomatic coronary thrombosis (n=3, 1 proximal and 2 distal CAF), and (C) partial thrombosis with residual cul-de-sac (n=1, proximal CAF) and vessel irregularity with stenosis (n=1, distal CAF). Finally, (III) persistent coronary artery dilation (n=4). Antiplatelets and anticoagulation were used in 31 and 7 patients post-closure, respectively. Overall, 7 of 10 (70%) with proximal CAF had optimal remodeling, but 5 of 11 (45%) with distal CAF had suboptimal remodeling. Only 1 of 7 patients with suboptimal remodeling were on anticoagulation. Conclusions: Neonates/infants with hemodynamically significant CAF can be treated by transcatheter or surgical closure with excellent procedural success. Patients with distal CAF are at higher risk for suboptimal remodeling. Postclosure anticoagulation and follow-up coronary anatomic evaluation are warranted.


2020 ◽  
Vol 2020 ◽  
pp. 1-8 ◽  
Author(s):  
Michal Galeczka ◽  
Malgorzata Szkutnik ◽  
Jacek Bialkowski ◽  
Sebastian Smerdzinski ◽  
Mateusz Knop ◽  
...  

Objectives. Patent ductus arteriosus (PDA) in elderly patients is an uncommon anomaly, and the duct itself is often calcified and fragile; therefore, transcatheter closure is more difficult. The aim is to analyse periprocedural and one-year follow-up results of transcatheter closure of PDA in such patients. Methods and results. Retrospective analysis of 33 elective patients aged ≥55 years (median 63; 56–85; 29 women), in whom PDA was closed percutaneously between 2002 and 2018 in two tertiary centres. All but three patients were symptomatic, with most in NYHA II (n = 14) and III (n = 11) class; pulmonary hypertension (n = 22), arterial hypertension (n = 22), duct calcifications (n = 17), atrial fibrillation (n = 15), significant mitral regurgitation (n = 5), and decompensated renal failure (n = 2) were observed. Different devices were applied depending on PDA morphology; nitinol wire mesh occluders with symmetrical articulating discs have been the most used in recent years (n = 11). Follow-up was conducted at an outpatient clinic (28/33 patients). The procedure was successful in all patients. There was one embolisation, followed by implantation of a larger device. No major complications were noted. A small residual shunt was present in echocardiography in one patient after one year. NYHA class improved in all but two patients (with multiple comorbidities). Conclusions. Transcatheter PDA closure in elderly patients is safe and efficient with a high complete closure rate and few complications. Amplatzer duct occluder type II is an attractive device in such patients.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
B Balcer ◽  
I Dykun ◽  
S Hendricks ◽  
F Al-Rashid ◽  
M Totzeck ◽  
...  

Abstract Background Anemia is a frequent comorbidity in patients with coronary artery disease (CAD). Besides a complemental effect on myocardial oxygen undersupply of CAD and anemia, available data suggests that it may independently impact the prognosis in CAD patients. We aimed to determine the association of anemia with long-term survival in a longitudinal registry of patients undergoing conventional coronary angiography. Methods The present analysis is based on the ECAD registry of patients undergoing conventional coronary angiography at the Department of Cardiology and Vascular Medicine at the University Clinic Essen between 2004 and 2019. For this analysis, we excluded all patients with missing hemoglobin levels at baseline admission or missing follow-up information. Anemia was defined as a hemoglobin level of &lt;13.0g/dl for male and &lt;12.0g/dl for female patients according to the world health organization's definition. Cox regression analysis was used to determine the association of anemia with morality, stratifying by clinical presentation of patients. Hazard ratio and 95% confidence interval are depicted for presence vs. absence of anemia. Results Overall, data from 28,917 patient admissions (mean age: 65.3±13.2 years, 69% male) were included in our analysis (22,570 patients without and 6,347 patients with anemia). Prevalence of anemia increased by age group (age &lt;50 years: 16.0%, age ≥80 years: 27.7%). During a mean follow-up of 3.2±3.4 years, 4,792 deaths of any cause occurred (16.6%). In patients with anemia, mortality was relevantly higher as compared to patients without anemia (13.4% vs. 28.0% for patients without and with anemia, respectively, p&lt;0.0001, figure 1). In univariate regression analysis, anemia was associated with 2.4-fold increased mortality risk (2.27–2.55, p&lt;0.0001). Effect sizes remained stable upon adjustment for traditional risk factors (2.38 [2.18–2.61], p&lt;0.0001). Mortality risk accountable to anemia was significantly higher for patients receiving coronary interventions (2.62 [2.35–2.92], p&lt;0.0001) as compared to purely diagnostic coronary angiography examinations (2.31 [2.15–2.47], p&lt;0.0001). Likewise, survival probability was slightly worse for patients with anemia in acute coronary syndrome (2.70 [2.29–3.12], p&lt;0.0001) compared to chronic coronary syndrome (2.60 [2.17–3.12], p&lt;0.0001). Interestingly, within the ACS entity, association of anemia with mortality was relevantly lower in STEMI patients (1.64 [1.10–2.44], p=0.014) as compared to NSTEMI and IAP (NSTEMI: 2.68 [2.09–3.44], p&lt;0.0001; IAP: 2.67 [2.06–3.47], p&lt;0.0001). Conclusion In this large registry of patients undergoing conventional coronary angiography, anemia was a frequent comorbidity. Anemia relevantly influences log-term survival, especially in patients receiving percutaneous coronary interventions. Our results confirm the important role of anemia for prognosis in patients with coronary artery disease, demonstrating the need for specific treatment options. Figure 1. Kaplan Meier analysis Funding Acknowledgement Type of funding source: None


2016 ◽  
Vol 115 (7) ◽  
pp. 571-576 ◽  
Author(s):  
Mao-Hung Lo ◽  
I-Chun Lin ◽  
Kai-Sheng Hsieh ◽  
Chien-Fu Huang ◽  
Shao-Ju Chien ◽  
...  

1999 ◽  
Vol 9 (5) ◽  
pp. 468-473 ◽  
Author(s):  
Felix Berger ◽  
Peter Ewert ◽  
Per G. Boöjrnstad ◽  
Ingo Dähnert ◽  
Gregor Krings ◽  
...  

AbstractTo judge whether an Amplatzer™ Septal Occluder can be used as standard therapy instead of surgery for closure of atrial septal defects we report our experiences in 200 patients. Of these patients, 127 had an atrial septal defect with haemodynamically significant left-to-right shunt, 68 patients a persistent oval foramen after presumed paradoxical embolism, and 5 had a fenestration after Fontan-repair. Mean age was 29.8 years (0.8 to 77.7 years). Body weight ranged from 6.9 to 120.0 kg (mean 51.5 kg). After diagnostic cardiac catheterization, and balloon-sizing of the defect, we implanted Amplatzer™ Septal Occluders with stents of 4 to 28 mm diameter. Follow-up studies were obtained after 48hours, and one, six, and twelve months. Transcatheter closure of the atrial septal defect proved successful in all without any relevant residual shunts. In particular, complete closure was achieved in all patients after presumed paradoxical embolism. The mean period of follow-up is 9–5 months, with a range from 0.4 to 23.5 months, giving a total of 1898 patient months. The occlusion rate after three month was 98.1°. A trivial haemodynamically insignificant residual shunt remained in 1.9° of the patients. Fluoroscopy times ranged from 0 to 43.5 minutes, with a median of 8.7 minutes. The excellent results in the short and medium term in children and adults have resulted in using this device routinely at the present time for closure of central atrial septal defects up to a diameter of 28 mm. Final judgement, however, is only possible after long-term follow-up.


Sign in / Sign up

Export Citation Format

Share Document