scholarly journals Negative pressure wound therapy and split thickness skin graft aided in the healing of extensive perineum necrotizing fasciitis without faecal diversion: a case report

BMC Surgery ◽  
2018 ◽  
Vol 18 (1) ◽  
Author(s):  
Yuan Tian ◽  
Ting Liu ◽  
Chuan-qi Zhao ◽  
Ze-yuan Lei ◽  
Dong-li Fan ◽  
...  
2018 ◽  
Vol 08 (02) ◽  
pp. 82-86
Author(s):  
Irfan Ilahi ◽  
M. Uzair Ilyas Tahir Kheli ◽  
Ehtesham- ulHaq

Background: Negative-pressure wound therapy (NPWT) or vacuum dressings involve the application of a controlled negative pressure on the wound. Traditionally, STSGs were fixed with bolster technique, where sutures are used to fix pressure dressings over the top of recently placed grafts. Taking it a step further in our study we applied an effective and user friendly filler material (surgical roll gauze) on very large defects. The objective of this study was to assess the clinical efficacy of gauze-based negative pressure wound therapy as an adjunctive therapy to STSG, over complex and very large wounds. Material & Methods: This descriptive study was conducted at Army Burn Center, Combined Military Hospital Kharian and PNS Shifa Hospital Karachi from January 2016 to June 2017. Gauze based VAC system used. Negative pressure was applied at -80 mm Hg. Evaluation was carried out to assess the performance of gauze-based NPWT. Results: Total of 63 patients, 42 males and 21 females, with mean age of 32 years SD+15 were included in the study. The wound size included in the study ranged from 12x10 cm to 88x66 cm. Mean duration of NPWT dressings was 15 days and 313 dressings were employed in total with satisfactory healing achieved in 3 to 4 VAC dressings in most of the cases. Mean duration of hospital stay was 23.92 days at which point graft uptake percentage was in the range of 90% (n=7) to 100% (n=20). Only 3.2% (n=2) cases required partial re-grafting for complete coverage of residual wounds. Conclusion: Gauze-based Negative-pressure wound therapy over split thickness skin graft is a cost-effective addition to the care and management of large and complex wounds


2019 ◽  
Vol 12 (9) ◽  
pp. e231197
Author(s):  
Victoria Elizabeth McKinnon ◽  
Jouseph Barkho ◽  
Mark H McRae

Exposure of a renal transplant through the abdominal wall is a rare event. A search of the literature reveals only six documented cases which used skin autograft for coverage, with none reported since 1981, and none which used negative-pressure wound therapy (NPWT) to prepare the recipient bed. This case report demonstrates that NPWT followed by split thickness skin graft is a reconstructive option which is feasible in patients who are at high risk for surgical complications in prolonged flap surgery.


2018 ◽  
Vol 03 (02) ◽  
pp. e46-e49
Author(s):  
Stuart Mitchell ◽  
Edward Ray ◽  
Peter Cordeiro

Background Multiple therapeutic options exist for the treatment of split-thickness skin graft (STSG) donor sites, but there is no clear consensus among surgeons about the best option. Negative-pressure wound therapy (NPWT) has rapidly gained in popularity since its invention. Recently, several miniaturized, single-patient NPWT (SP-NPWT) devices have become available. Compared with traditional NPWT devices, SP-NPWT devices are associated with equal wound healing capability and reliability, but offer several advantages. We present a series of 10 consecutive patients whose STSG donor sites were treated with a commercially available SP-NPWT device. Methods We performed a retrospective review for 10 consecutive patients who underwent STSG procedures and were treated with SP-NPWT devices. Results From 2015 to 2017, 10 consecutive patients underwent oncologic reconstruction using STSG and had their donor sites treated with SP-NPWT devices. The SP-NPWT dressing had been left in place for 2 weeks after surgery. The average donor site area measured 80 cm2 (range: 76–106 cm2). In all 10 patients, the donor sites healed uneventfully and with no complications. Conclusion Off-the-shelf, miniaturized, SP-NPWT systems appear to be at least as effective as traditional dressings for STSG donor sites and require no maintenance (skilled nursing or dressing changes). Compared with larger and less portable standard NPWT devices, SP-NPWT dressing systems provide a potential cost benefit as well as enhanced convenience and portability.


2019 ◽  
Vol 13 (5) ◽  
pp. 383-391
Author(s):  
Efthymios Gkotsoulias

Split thickness skin graft (STSG) is a versatile procedure performed for the treatment of wounds resulting from varying pathology. This remains very useful because of its ability for quick healing and low complication rate. The surface of the foot and ankle is an area frequently affected by severe skin and soft tissue structure infections (SSTIs) whose treatment results in wounds. These infections and resultant surgical wounds are commonly seen patients with diabetes. The objective of the present study was to retrospectively evaluate initial healing and immediate post-operative outcomes following STSG application in a diabetic population when negative pressure wound therapy (NPWT) was used as a bolster. Ten patients were identified, including 11 surgical wounds, who underwent STSG bolstered with NPWT from January 2016 to October 2018. Mean follow-up was 13 months (range 1-33 months) with an average time to heal of 17 days (range 14-30 days) for 11 surgical wounds averaging 57 cm2 (range 6.3 - 91 cm2). Consistent improved outcomes have been demonstrated when compared to alternative bolstering techniques available in the literature making a STSG bolstered with NPWT a powerful tool in the reconstruction of diabetic foot wounds resulting from the treatment of infection. Levels of Evidence: Level IV


Sign in / Sign up

Export Citation Format

Share Document