scholarly journals Electrical impedance tomography to titrate positive end-expiratory pressure in COVID-19 acute respiratory distress syndrome

Critical Care ◽  
2020 ◽  
Vol 24 (1) ◽  
Author(s):  
François Perier ◽  
Samuel Tuffet ◽  
Tommaso Maraffi ◽  
Glasiele Alcala ◽  
Marcus Victor ◽  
...  

Abstract Rationale Patients with coronavirus disease-19-related acute respiratory distress syndrome (C-ARDS) could have a specific physiological phenotype as compared with those affected by ARDS from other causes (NC-ARDS). Objectives To describe the effect of positive end-expiratory pressure (PEEP) on respiratory mechanics in C-ARDS patients in supine and prone position, and as compared to NC-ARDS. The primary endpoint was the best PEEP defined as the smallest sum of hyperdistension and collapse. Methods Seventeen patients with moderate-to-severe C-ARDS were monitored by electrical impedance tomography (EIT) and evaluated during PEEP titration in supine (n = 17) and prone (n = 14) position and compared with 13 NC-ARDS patients investigated by EIT in our department before the COVID-19 pandemic. Results As compared with NC-ARDS, C-ARDS exhibited a higher median best PEEP (defined using EIT as the smallest sum of hyperdistension and collapse, 12 [9, 12] vs. 9 [6, 9] cmH2O, p < 0.01), more collapse at low PEEP, and less hyperdistension at high PEEP. The median value of the best PEEP was similar in C-ARDS in supine and prone position: 12 [9, 12] vs. 12 [10, 15] cmH2O, p = 0.59. The response to PEEP was also similar in C-ARDS patients with higher vs. lower respiratory system compliance. Conclusion An intermediate PEEP level seems appropriate in half of our C-ARDS patients. There is no solid evidence that compliance at low PEEP could predict the response to PEEP.

2021 ◽  
Vol 8 ◽  
Author(s):  
Sébastien Gibot ◽  
Marie Conrad ◽  
Guilhem Courte ◽  
Aurélie Cravoisy

Introduction: The best way to titrate the positive end-expiratory pressure (PEEP) in patients suffering from acute respiratory distress syndrome is still matter of debate. Electrical impedance tomography (EIT) is a non-invasive technique that could guide PEEP setting based on an optimized ventilation homogeneity.Methods: For this study, we enrolled the patients with 2019 coronavirus disease (COVID-19)-related acute respiratory distress syndrome (ARDS), who required mechanical ventilation and were admitted to the ICU in March 2021. Patients were monitored by an esophageal catheter and a 32-electrode EIT device. Within 48 h after the start of mechanical ventilation, different levels of PEEP were applied based upon PEEP/FiO2 tables, positive end-expiratory transpulmonary (PL)/ FiO2 table, and EIT. Respiratory mechanics variables were recorded.Results: Seventeen patients were enrolled. PEEP values derived from EIT (PEEPEIT) were different from those based upon other techniques and has poor in-between agreement. The PEEPEIT was associated with lower plateau pressure, mechanical power, transpulmonary pressures, and with a higher static compliance (Crs) and homogeneity of ventilation.Conclusion: Personalized PEEP setting derived from EIT may help to achieve a more homogenous distribution of ventilation. Whether this approach may translate in outcome improvement remains to be investigated.


2021 ◽  
Vol 7 (1) ◽  
pp. 62-66
Author(s):  
Atsuko Shono ◽  
Toru Kotani ◽  
Inéz Frerichs

Abstract Introduction Each patient suffering from severe coronavirus COVID-19-associated acute respiratory distress syndrome (ARDS), requiring mechanical ventilation, shows different lung mechanics and disease evolution. Therefore, lung protective strategies should be personalised for the individual patient. Case presentation A 64-year-old male patient was intubated ten days after the symptoms of COVID-19 infection presented. He was placed in the prone position for sixteen hours, resulting in a marked improvement in oxygenation. However, after being returned to the supine position, his SpO2 rapidly dropped from 98% to 91%, and electrical impedance tomography showed less ventilation at the dorsal region and a ventral shift of ventilation distribution. An incremental and decremental PEEP trial under electrical impedance tomography monitoring was carried out, confirming that the dependent lung regions were recruited with increased pressures and homogenous ventilation distribution could be provided with 14 cmH2O of PEEP. The optimal settings were reassessed next day after returning from the second session of the prone position. After four prone position-sessions in five days, oxygenation was stabilised and eventually the patient was discharged. Conclusions Patients with COVID-19 associated ARDS require individualised ventilation support depending on the stage of their disease. Daily PEEP trial monitored by electrical impedance tomography can provide important information to tailor the respiratory therapies.