scholarly journals Evaluation using a four-dimensional imaging tool before and after pulmonary valve replacement in a patient with tetralogy of Fallot: a case report

2019 ◽  
Vol 13 (1) ◽  
Author(s):  
Masao Takigami ◽  
Keiichi Itatani ◽  
Naohiko Nakanishi ◽  
Kosuke Nakaji ◽  
Yo Kajiyama ◽  
...  
2020 ◽  
Vol 318 (2) ◽  
pp. H345-H353 ◽  
Author(s):  
Pia Sjöberg ◽  
Ellen Ostenfeld ◽  
Erik Hedström ◽  
Håkan Arheden ◽  
Ronny Gustafsson ◽  
...  

Timing and indication for pulmonary valve replacement (PVR) in patients with repaired Tetralogy of Fallot (rToF) and pulmonary regurgitation (PR) are uncertain. To improve understanding of pumping mechanics, we investigated atrioventricular coupling before and after surgical PVR. Cardiovascular magnetic resonance was performed in patients ( n = 12) with rToF and PR > 35% before and after PVR and in healthy controls ( n = 15). Atrioventricular plane displacement (AVPD), global longitudinal peak systolic strain (GLS), atrial and ventricular volumes, and caval blood flows were analyzed. Right ventricular (RV) AVPD and RV free wall GLS were lower in patients before PVR compared with controls ( P < 0.0001; P < 0.01) and decreased after PVR ( P < 0.0001 for both). Left ventricular AVPD was lower in patients before PVR compared with controls ( P < 0.05) and decreased after PVR ( P < 0.01). Left ventricular GLS did not differ between patients and controls ( P > 0.05). Right atrial reservoir volume and RV stroke volume generated by AVPD correlated in controls ( r = 0.93; P < 0.0001) and patients before PVR ( r = 0.88; P < 0.001) but not after PVR. In conclusion, there is a clear atrioventricular coupling in patients before PVR that is lost after PVR, possibly because of loss of pericardial integrity. Impaired atrioventricular coupling complicates assessment of ventricular function after surgery using measurements of longitudinal function. Changes in atrioventricular coupling seen in patients with rToF may be energetically unfavorable, and long-term effects of surgery on atrioventricular coupling is therefore of interest. Also, AVPD and GLS cannot be used interchangeably to assess longitudinal function in rToF. NEW & NOTEWORTHY There is a clear atrioventricular coupling in patients with Tetralogy of Fallot (ToF) and pulmonary regurgitation before surgical pulmonary valve replacement (PVR) that is lost after operation, possibly because of loss of pericardial integrity. The impaired atrioventricular coupling complicates assessment of ventricular function after surgery when using measurements of longitudinal function. Left ventricular atrioventricular plane displacement (AVPD) found differences between patients and controls and changes after PVR that longitudinal strain could not detect. This indicates that AVPD and strain cannot be used interchangeably to assess longitudinal function in repaired ToF.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Masateru Kawakubo ◽  
Yuzo Yamasaki ◽  
Daisuke Toyomura ◽  
Kenichiro Yamamura ◽  
Ichiro Sakamoto ◽  
...  

AbstractWe measured right ventricular (RV) strain by applying a novel postprocessing technique to conventional short-axis cine magnetic resonance imaging in the repaired tetralogy of Fallot (TOF) and investigated whether pulmonary valve replacement (PVR) changes the RV strain. Twenty-four patients with repaired TOF who underwent PVR and 16 healthy controls were enrolled. Global maximum and minimum principal strains (GPSmax, GPSmin) and global circumferential and longitudinal strains (GCS, GLS) were measured from short-axis cine images reconstructed radially along the long axis. Strain parameters before and after PVR were compared using paired t-tests. One-way ANOVA with Tukey post-hoc analysis was used for comparisons between the before and after PVR groups and the control group. There were no differences in strain parameters before and after PVR. The GPSmax before PVR was lower than that in the control group (P = 0.002). Before and after PVR, GCSs were higher and GLSs were lower than those in the control group (before and after GCSs: P = 0.002 for both, before and after GLSs: P < 0.0001 and P = 0.0003). RV strains from radially reconstructed short-axis cine images revealed unchanged myocardial motion after PVR. When compared to the control group, changes in GCS and GLS in TOF patients before and after PVR might be due to RV remodeling.


2021 ◽  
Author(s):  
Masateru Kawakubo ◽  
Yuzo Yamasaki ◽  
Daisuke Toyomura ◽  
Kenichiro Yamamura ◽  
Ichiro Sakamoto ◽  
...  

Abstract Objectives: To investigate changes in right ventricular (RV) strain after pulmonary valve replacement (PVR) in repaired tetralogy of Fallot (TOF) by applying a novel postprocessing technique to conventional short-axis cine MRI to measure RV strains before and after PVR.Methods: Twenty-four patients with repaired TOF who underwent PVR and 16 healthy controls were enrolled. Global maximum and minimum principal strains (GPSmax, GPSmin) and global circumferential and longitudinal strains (GCS, GLS) were measured from short-axis cine images reconstructed radially along the long axis. Strain parameters before and after PVR were compared using paired t-tests. One-way ANOVA with Tukey post-hoc analysis was used for comparisons between the before and after PVR groups and the control group. Results: There were no differences in strain parameters before and after PVR. The GPSmax before PVR was lower than that in the control group (P=0.002). Before and after PVR, GCSs were higher and GLSs were lower than those in the control group (before and after GCSs: P=0.002 for both, before and after GLSs: P<0.0001 and P=0.0003). Conclusions: RV strains from radially reconstructed short-axis cine images revealed impaired myocardial motion after PVR. When compared to the control group, changes in GCS and GLS in TOF patients before and after PVR might be due to RV remodeling.


Sign in / Sign up

Export Citation Format

Share Document