In-Process Inspection System Using Tool-Touch Auditron

2020 ◽  
pp. 197-222
Author(s):  
William S. Mcknight
Keyword(s):  
2004 ◽  
Vol 58 (3) ◽  
pp. 321-327
Author(s):  
Akihiro Terada
Keyword(s):  

2016 ◽  
Vol 70 (10) ◽  
pp. 1014-1016
Author(s):  
Satoshi Suzuki

Author(s):  
Mike Santana ◽  
Alfredo V. Herrera

Abstract This paper describes a methodology for correlating physical defect inspection/navigation systems with electrical bitmap data through the fabrication of artificial defects via reticle alterations or circuit modifications using an inline FIB. The methodology chosen consisted of altering decommissioned reticles to create defects resulting in both open and shorted circuits within areas of an AMD microprocessor cache. The reticles were subsequently scanned using a KLA SL300HR StarLight inspection system to confirm their location, while wafers processed on these reticles were scanned at several layers using standard inline metrology. Finally, the wafers were electrically tested, bitmapped, and physically deprocessed. All defect data was then analyzed and cross-correlated between each system, uncovering some important system deficiencies and learning opportunities. Data and images are included to support the significance and effectiveness of such a methodology.


2018 ◽  
Author(s):  
W.F. Hsieh ◽  
Henry Lin ◽  
Vincent Chen ◽  
Irene Ou ◽  
Y.S. Lou

Abstract This paper describes the investigation of donut-shaped probe marker discolorations found on Al bondpads. Based on SEM/EDS, TEM/EELS, and Auger analysis, the corrosion product is a combination of aluminum, fluorine, and oxygen, implying that the discolorations are due to the presence of fluorine. Highly accelerated stress tests simulating one year of storage in air resulted in no new or worsening discolorations in the affected chips. In order to identify the exact cause of the fluorine-induced corrosion, the authors developed an automated inspection system that scans an entire wafer, recording and quantifying image contrast and brightness variations associated with discolorations. Dark field TEM images reveal thickness variations of up to 5 nm in the corrosion film, and EELS line scan data show the corresponding compositional distributions. The findings indicate that fluorine-containing gases used in upstream processes leave residues behind that are driven in to the Al bondpads by probe-tip forces and activated by the electric field generated during CP testing. The knowledge acquired has proven helpful in managing the problem.


Sign in / Sign up