Application of 3D and 4D ultrasound in fetal medicine

2021 ◽  
pp. 59.1-59.15
Author(s):  
Eberhard Merz
Keyword(s):  
2018 ◽  
Vol 46 (6) ◽  
pp. 631-639
Author(s):  
Raul Moreira Neto ◽  
Selma Porovic

AbstractFetal neurology is evolving as an area of great interest in prenatal diagnosis and fetal medicine. The identification and diagnosis of brain damage prenatally has been a great challenge in obstetrics for many years. Investigations of fetal behavior in comparison with morphological studies led to the conclusion that fetal behavioral patterns directly reflect developmental and maturational processes of the fetal central nervous system (CNS). Four-dimensional (4D) ultrasound has greatly improved the assessment of the quality of the fetal spontaneous movements, and enabled a better evaluation of fetal behavior. The assessment of normal neurobehavioral development by 4D ultrasound provided the opportunity to investigate functional characteristics of the fetus that could predict neurological developmental dysfunction. Some studies have already been carried out to evaluate this new methodology in the observation of fetal behavior during different stages of gestation, in an attempt to better understand the relationships between the maturation of the CNS of the fetus and its implications on its behavior pattern. We present a review of literature on fetal behavior by 4D ultrasound.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Svenja Ipsen ◽  
Sven Böttger ◽  
Holger Schwegmann ◽  
Floris Ernst

AbstractUltrasound (US) imaging, in contrast to other image guidance techniques, offers the distinct advantage of providing volumetric image data in real-time (4D) without using ionizing radiation. The goal of this study was to perform the first quantitative comparison of three different 4D US systems with fast matrix array probes and real-time data streaming regarding their target tracking accuracy and system latency. Sinusoidal motion of varying amplitudes and frequencies was used to simulate breathing motion with a robotic arm and a static US phantom. US volumes and robot positions were acquired online and stored for retrospective analysis. A template matching approach was used for target localization in the US data. Target motion measured in US was compared to the reference trajectory performed by the robot to determine localization accuracy and system latency. Using the robotic setup, all investigated 4D US systems could detect a moving target with sub-millimeter accuracy. However, especially high system latency increased tracking errors substantially and should be compensated with prediction algorithms for respiratory motion compensation.


Author(s):  
Catherine Finnegan ◽  
Suzanne Smyth ◽  
Orla Smith ◽  
Karen Flood ◽  
Jane Dalrymple ◽  
...  

Abstract Purpose Despite the rise of non-invasive screening tests for fetal aneuploidy, invasive testing during pregnancy remains the definitive diagnostic tool for fetal genetic anomalies. Results are rapidly available with polymerase chain reaction (PCR) tests, but cases have been reported whereby initial results were not confirmed after pregnancy termination and the fetal karyotype was ultimately normal. We sought to examine the potential discordance between PCR and karyotype for fetal aneuploidy. Methods The results from all amniocentesis and CVS tests performed over a 6-year period in a large tertiary level fetal medicine unit were reviewed. The results of PCR and karyotype were recorded and discrepancies examined. Pregnancy outcomes were also recorded. Results A total of 1222 invasive tests were performed (716 amniocentesis and 506 CVS). Within the cohort having amniocentesis, 11 had discrepant results (normal QF-PCR result but with a subsequent abnormal karyotype). There was 1 case among this group which QF-PCR should have identified. Within the CVS group, 7 patients had discrepant results. All had a diploid QF-PCR and would not have been identified as abnormal by it. Conclusion PCR can be reliably used to determine aneuploidy of chromosomes 13, 18, and 21. However, in cases of sex chromosome aneuploidy, its performance is less reliable and warrants waiting for a complete karyotype. Given such discordance, we advise waiting for karyotype for all invasive tests performed in the presence of a normal ultrasound before advising a patient of a diploid QF-PCR result or potentially terminating a normal pregnancy.


2021 ◽  
Vol 224 (2) ◽  
pp. S162-S163
Author(s):  
Margot M. Gurganus ◽  
Isabelle Gill ◽  
Erica Mark ◽  
Olivia Payne ◽  
Donald Dudley