Ventilation Effectiveness and Air Distribution

2004 ◽  
pp. 509-566
Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1835 ◽  
Author(s):  
Arman Ameen ◽  
Mathias Cehlin ◽  
Ulf Larsson ◽  
Taghi Karimipanah

A vital requirement for all-air ventilation systems are their functionality to operate both in cooling and heating mode. This article experimentally investigates two newly designed air distribution systems, corner impinging jet (CIJV) and hybrid displacement ventilation (HDV) in comparison against a mixing type air distribution system. These three different systems are examined and compared to one another to evaluate their performance based on local thermal comfort and ventilation effectiveness when operating in heating mode. The evaluated test room is an office environment with two workstations. One of the office walls, which has three windows, faces a cold climate chamber. The results show that CIJV and HDV perform similar to a mixing ventilation in terms of ventilation effectiveness close to the workstations. As for local thermal comfort evaluation, the results show a small advantage for CIJV in the occupied zone. Comparing C2-CIJV to C2-CMV the average draught rate (DR) in the occupied zone is 0.3% for C2-CIJV and 5.3% for C2-CMV with the highest difference reaching as high as 10% at the height of 1.7 m. The results indicate that these systems can perform as well as mixing ventilation when used in offices that require moderate heating. The results also show that downdraught from the windows greatly impacts on the overall airflow and temperature pattern in the room.


2016 ◽  
Vol 130 ◽  
pp. 733-746 ◽  
Author(s):  
Shazia Ahmed Ameer ◽  
Hassam Nasarullah Chaudhry ◽  
Arouge Agha

2016 ◽  
Vol 24 (03) ◽  
pp. 1650019
Author(s):  
Yong-Il Kwon

In the air distribution design of a small theater, either a downward or an upward displacement ventilation is applied generally. The cool air is supplied from openings distributed over the ceiling and extracted beneath the seats for the downward flow and supplied from beneath the seats and extracted from the ceiling for the upward flow system. By the change of air exchange rate (ACH) produced by two divergent ventilation systems inside theater, thermal comfort and ventilation effectiveness around the seats show a different phenomenon. Thereby, it can be seen that the selection of the ventilation system is a significant factor in energy saving. CFD calculations for this study were performed to investigate the effects of various parameters (ADPI and ACE) of air distribution system applied in order to save the cooling energy. This paper focuses mainly on the effect of the varied volume flow rate depending on the ventilation system. The ventilation performances of the downward displacement system are compared quantitatively with the upward displacement system using the concept of the LMA of fresh air.


2012 ◽  
Vol 55 ◽  
pp. 94-101 ◽  
Author(s):  
Michal Krajčík ◽  
Angela Simone ◽  
Bjarne W. Olesen