Experimental investigation on the effectiveness of patch repair on the flexural behavior of corroded post-tensioned beams

2018 ◽  
Author(s):  
◽  
Ayman Elzohairy

[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The steel-concrete composite beam represents a structural system widely employed in both buildings and girder bridges. The coupling between steel beams and concrete flanges assures both economic and structural benefits because of quick construction of steel structures and large increase in stiffness due to the presence of concrete. Strengthening with external post-tensioning (PT) force is particularly effective and economical for long-span steel-concrete composite beams and has been employed with great success to increase the bending and shear resistance and correct excessive deflections. Applying external PT force to the steel-concrete composite beam is considered an active strengthening technique that can create permanent internal straining action in the beam which is opposite to the existing straining action due to the applied service loads. The most benefits of using this system of strengthening are an elastic performance to higher loads, higher ultimate capacity, and reduction in deformation under the applied loads. Under service loads, bridge superstructures are subjected to cyclic loads which may cause a premature failure due to fatigue. Therefore, fatigue testing is critical to evaluate existing design methods of steel-concrete composite beams. ... This research presents static and fatigue tests on four steel-concrete composite specimens to evaluate the effect of externally post-tensioned tendons on the ultimate strength and fatigue behavior of composite beams. Fatigue tests are conducted to a million cycles under a four-point bending test. In addition, final static tests are performed on fatigued specimens to evaluate the residual strength of the strengthened specimen. A numerical model is described to predict the fatigue response of the composite beam by considering the fatigue damage in the concrete flange. The accuracy of the developed numerical model is validated using the existing test data. The static test results indicate that the external post-tensioning force improves the flexural behavior of the strengthened specimen by increasing the beam capacity and reducing the tensile stress in the bottom flange of the steel beam. The fatigue results demonstrate that the external post-tensioning significantly decreases the strains in the shear connectors, concrete flange, and steel beam. The tendons demonstrated an excellent fatigue performance, with no indication of distress at the anchors.


2021 ◽  
pp. 103651
Author(s):  
Si Chen ◽  
Yang Wei ◽  
Kang Zhao ◽  
Fenghui Dong ◽  
Linjie Huang

2019 ◽  
Vol 222 ◽  
pp. 110926 ◽  
Author(s):  
Daniel C.T. Cardoso ◽  
Gabriel B.S. Pereira ◽  
Flávio A. Silva ◽  
Julio J.H. Silva Filho ◽  
Eric V. Pereira

Structures ◽  
2019 ◽  
Vol 19 ◽  
pp. 286-295 ◽  
Author(s):  
Ehsan Nikbakht ◽  
Amin Al-Fakih ◽  
Chieng Chew Hui ◽  
Lee Yuan Jake ◽  
Mst. Sadia Mahzabin

Sign in / Sign up

Export Citation Format

Share Document