scholarly journals Practical Considerations for Initiating and Utilizing Flash Continuous Glucose Monitoring in Clinical Practice

Author(s):  
Carol H Wysham ◽  
Davida F Kruger

Abstract Use of continuous glucose monitoring (CGM) has been shown to improve clinical outcomes in type 1 diabetes (T1D) and type 2 diabetes (T2D), including improved glycemic control, better treatment adherence and an increased understanding of their treatment regimens. Retrospective analysis of CGM data allows clinicians and patients to identify glycemic patterns that support and facilitate informed therapy adjustments. There are currently two types of CGM systems: real-time CGM (rtCGM) and flash CGM. The FreeStyle Libre 2 (FLS2) is the newest flash CGM system commercially available. Because the FLS2 system was only recently cleared for use in the US, many endocrinologists and diabetes specialists may be unfamiliar with strengths, limitations and potential of the FSL2 system. This article focuses on practical approaches and strategies for initiating and using flash CGM in endocrinology and diabetes specialty practices.

Diabetes ◽  
2021 ◽  
Vol 70 (Supplement 1) ◽  
pp. 68-LB
Author(s):  
IRL B. HIRSCH ◽  
GREGORY J. ROBERTS ◽  
JENNIFER JOSEPH ◽  
YELENA NABUTOVSKY ◽  
NAUNIHAL VIRDI ◽  
...  

2012 ◽  
Vol 08 (01) ◽  
pp. 22 ◽  
Author(s):  
M Susan Walker ◽  
Stephanie J Fonda ◽  
Sara Salkind ◽  
Robert A Vigersky ◽  
◽  
...  

Previous research has shown that realtime continuous glucose monitoring (RT-CGM) is a useful clinical and lifestyle aid for people with type 1 diabetes. However, its usefulness and efficacy for people with type 2 diabetes is less known and potentially controversial, given the continuing controversy over the efficacy of self-monitoring of blood glucose (SMBG) in this cohort. This article reviews theextantliterature on RT-CGM for people with type 2 diabetes, and enumerates several of the advantages and disadvantages of this technology from the perspective of providers and patients. Even patients with type 2 diabetes who are not using insulin and/or are relatively well controlled on oral medications have been shown to spend a significant amount of time each day in hyperglycemia. Additional tools beyond SMBG are necessary to enable providers and patients to clearly grasp and manage the frequency and amplitude of glucose excursions in people with type 2 diabetes who are not on insulin. While SMBG is useful for measuring blood glucose levels, patients do not regularly check and SMBG does not enable many to adequately manage blood glucose levels or capture marked and sustained hyperglycemic excursions. RT-CGM systems, valuable diabetes management tools for people with type 1 diabetes or insulin-treated type 2 diabetes, have recently been used in type 2 diabetes patients. Theextantstudies, although few, have demonstrated that the use of RT-CGM has empowered people with type 2 diabetes to improve their glycemic control by making and sustaining healthy lifestyle choices.


2021 ◽  
Author(s):  
Ronan Roussel ◽  
Jean-Pierre Riveline ◽  
Eric Vicaut ◽  
Gérard de Pouvourville ◽  
Bruno Detournay ◽  
...  

<b>Objective</b> <p>The RELIEF study assessed rates of hospitalization for acute diabetes complications in France, before and after initiating the FreeStyle Libre system. </p> <p><b>Research Design and Methods</b></p> <p>74,011 patients with type 1 diabetes or type 2 diabetes who initiated the FreeStyle Libre system were identified from the French national claim database (SNDS) using ICD-10 codes, from hospitalizations with diabetes as a contributing diagnosis, or the prescription of insulin. Patients were sub-classified based on SMBG strip-acquisition prior to starting FreeStyle Libre. Hospitalizations for DKA, severe hypoglycemia, diabetes-related coma and hyperglycemia were recorded for the 12 months before and after initiation. </p> <p><b>Results</b></p> <p>Hospitalizations for acute diabetes complications fell in type 1 diabetes (-49.0%) and in type 2 diabetes (-39.4%) following FreeStyle Libre initiation. DKA fell in type 1 diabetes (-56.2%,) and in type 2 diabetes (-52.1%), as did diabetes-related comas in type 1 diabetes (-39.6%) and in type 2 diabetes (-31.9%). Hospitalizations for hypoglycemia and hyperglycemia decreased in type 2 diabetes (-10.8% and -26.5%, respectively). Before initiation, hospitalizations were most marked for people non-compliant with SMBG and for those with highest acquisition of SMBG, which fell by -54.0% and 51.2% respectively following FreeStyle Libre initiation. Persistence with FreeStyle Libre at 12 months was 98.1%.</p> <p><b>Conclusions</b></p> <p>This large retrospective study on hospitalizations for acute diabetes complication shows that a significantly lower incidence of admissions for DKA and for diabetes-related coma is associated with use of flash glucose monitoring. This study has significant implications for patient-centered diabetes care and potentially for long-term health economic outcomes.</p> <br> <p> </p>


2021 ◽  
Author(s):  
Ronan Roussel ◽  
Jean-Pierre Riveline ◽  
Eric Vicaut ◽  
Gérard de Pouvourville ◽  
Bruno Detournay ◽  
...  

<b>Objective</b> <p>The RELIEF study assessed rates of hospitalization for acute diabetes complications in France, before and after initiating the FreeStyle Libre system. </p> <p><b>Research Design and Methods</b></p> <p>74,011 patients with type 1 diabetes or type 2 diabetes who initiated the FreeStyle Libre system were identified from the French national claim database (SNDS) using ICD-10 codes, from hospitalizations with diabetes as a contributing diagnosis, or the prescription of insulin. Patients were sub-classified based on SMBG strip-acquisition prior to starting FreeStyle Libre. Hospitalizations for DKA, severe hypoglycemia, diabetes-related coma and hyperglycemia were recorded for the 12 months before and after initiation. </p> <p><b>Results</b></p> <p>Hospitalizations for acute diabetes complications fell in type 1 diabetes (-49.0%) and in type 2 diabetes (-39.4%) following FreeStyle Libre initiation. DKA fell in type 1 diabetes (-56.2%,) and in type 2 diabetes (-52.1%), as did diabetes-related comas in type 1 diabetes (-39.6%) and in type 2 diabetes (-31.9%). Hospitalizations for hypoglycemia and hyperglycemia decreased in type 2 diabetes (-10.8% and -26.5%, respectively). Before initiation, hospitalizations were most marked for people non-compliant with SMBG and for those with highest acquisition of SMBG, which fell by -54.0% and 51.2% respectively following FreeStyle Libre initiation. Persistence with FreeStyle Libre at 12 months was 98.1%.</p> <p><b>Conclusions</b></p> <p>This large retrospective study on hospitalizations for acute diabetes complication shows that a significantly lower incidence of admissions for DKA and for diabetes-related coma is associated with use of flash glucose monitoring. This study has significant implications for patient-centered diabetes care and potentially for long-term health economic outcomes.</p> <br> <p> </p>


2018 ◽  
Vol 12 (2) ◽  
pp. 393-396 ◽  
Author(s):  
Peter Calhoun ◽  
Terri Kang Johnson ◽  
Jonathan Hughes ◽  
David Price ◽  
Andrew K. Balo

Acetaminophen (APAP) can cause erroneously high readings in real-time continuous glucose monitoring (rtCGM) systems. APAP-associated bias in an investigational rtCGM system (G6) was evaluated by taking the difference in glucose measurements between rtCGM and YSI from 1 hour before to 6 hours after a 1-g oral APAP dose in 66 subjects with type 1 or type 2 diabetes. The interference effect was defined as the average post-dose (30-90 minutes) bias minus the average baseline bias for each subject. The clinically meaningful interference effect was defined as 10 mg/dL. The G6 system’s overall mean (±SD) interference effect was 3.1 ± 4.8 mg/dL (one-sided upper 95% CI = 4.1 mg/dL), significantly lower than 10 mg/dL. The G6 system’s resistance to APAP interference should provide reassurance to those using the drug.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Satoshi Ida ◽  
Ryutaro Kaneko ◽  
Kanako Imataka ◽  
Kaoru Okubo ◽  
Yoshitaka Shirakura ◽  
...  

The aim of this study was to evaluate the effects of flash glucose monitoring on dietary variety, physical activity, and self-care behavior in patients with diabetes. This study included outpatients with diabetes using insulin who presented at the Department of Diabetes and Metabolism of the Ise Red Cross Hospital. Before initiating flash glucose monitoring and 12 weeks after its initiation, blood glucose-related parameters were assessed and self-administered questionnaires were completed (Dietary Variety Score (DVS), the International Physical Activity Questionnaire (IPAQ), the Summary of Diabetes Self-Care Activities Measure (SDSCA), and the Diabetes Treatment Satisfaction Questionnaire (DTSQ)) and compared between the two time points. We analyzed 42 patients with type 1 diabetes mellitus and 48 patients with type 2 diabetes mellitus. In patients with type 2 diabetes mellitus, but not type 1 diabetes mellitus, there was an increase in moderate/high category scores for IPAQ (P<0.001) and for treatment satisfaction reported via DTSQ. Furthermore, in patients with type 2 diabetes mellitus, the glycemic excursion index improved significantly and HbA1c decreased significantly (from 7.7 (1.2) to 7.4 (0.8), P=0.025). Results showed that standard deviation and mean amplitude of glycemic excursions significantly decreased in patients with type 1 diabetes mellitus (from 71.2 (20.4) to 66.2 (17.5), P=0.033 and from 124.6 (31.9) to 108.1 (28.4), P<0.001, respectively). Flash glucose monitoring is a useful tool to improve physical activity in patients with type 2 diabetes.


2021 ◽  
pp. 286-292
Author(s):  
G. E. Runova

Glycemic control represents an integral part of diabetes mellitus (DM) therapy. It is not surprising that diabetes technology is evolving to not only create new routes of insulin administration, but also to improve the measurement of glycemia. A significant number of new glucose monitoring systems have been launched to the market over the past 10 years. Nevertheless, only 30% of patients with type 1 diabetes and very few patients with type 2 diabetes use continuous or flash glucose monitoring. The reason for this is not only the cost and technical difficulties of continuous glucose monitoring, but also its clinical appropriateness. There is indisputable evidence that patients who receive intensified insulin therapy, especially those with type 1 diabetes, need frequent self-monitoring / continuous glucose monitoring. As for patients with type 2 diabetes receiving basal insulin and / or other antihyperglycemic therapy, the data received seem to be contradictory and uncertain. However, most of the recommendations simmer down to the need for self-monitoring of blood glucose levels in patients with type 2 diabetes. The diabetes technology section of the American Diabetes Association guidelines 2021 goes into details about the role of self-monitoring of blood glucose in diabetes management, including the need for continuous patient education on the principles and rules of self-monitoring, interpretation and practical use of the results of self-monitoring, various standards of glucometers, factors affecting the accuracy of the results. 