scholarly journals The Ion-exchange Equilibrium between Cesium and Phenol-sulfonic-acid-type Cation Exchange Resin

1963 ◽  
Vol 36 (8) ◽  
pp. 1038-1043 ◽  
Author(s):  
Hiroyuki Tsubota
1977 ◽  
Vol 23 (10) ◽  
pp. 1921-1924 ◽  
Author(s):  
G J Alexander ◽  
S Machiz

Abstract A convenient screening procedure for presence of drugs of abuse in urine consists of two steps: adsorption of the drugs from urine onto a paper loaded with cation-exchange resin and detection of the adsorbed drugs by direct radioimmunoassay. The first step can be performed in the field, the second in a central laboratory. Storage and transport to the laboratory are simplified because specimens adsorbed on dried paper are stable and can be sent in letter-mail. In the laboratory, a small disc of the ion-exchange paper is exposed to antigen and antibody, rinsed, and tested for radioactivity. Discs treated with positive urines are more radioactive than discs from negative urines.


2014 ◽  
Vol 900 ◽  
pp. 361-364
Author(s):  
Xiao Hui Wang ◽  
Xi Hua Du ◽  
Li Min Dong

Esters of Citric acid and palmityl alcohol were synthesized by esterification reaction under catalysis of cation exchange resin and P-toluene sulfonic acid respectively. The effects of amount of catalyst, ratio of raw materials, reaction time and temperature on the synthesis reaction were investigated . The experimental results showed that optimum of process conditions were 1:1~1:1.5 molar ratio of citric acid and palmityl alcohol, reaction temperature of 130~140°C, reaction time of 2 h. Conversion of palmityl alcohol were all more than 90% under 0.3% dosage using p-toluene sulfonic acid as the catalyst, or 0.5% dosage using 721 cation exchange resin with sulfonic acid type as catalyst. The synthesized product had good surface activity.


1980 ◽  
Vol 63 (3) ◽  
pp. 460-461
Author(s):  
Saidul Z Qureshi ◽  
Fadhil M Najib ◽  
Fahmi A Mohammed

Abstract An ion exchange method to determine the alkalinity of water-soluble tea ash containing high levels of manganese is described. A chromatographic column containing a strong cation exchange resin (20–50 mesh) in Na+ form, with a bed volume of 5 mL is used. The present ion exchange method is compared to pH titrations and also to the official AOAC methods (31.012, 31.015, 31.016). Results with the new method are accurate and precise.


ChemInform ◽  
2008 ◽  
Vol 39 (22) ◽  
Author(s):  
Victor D. Filimonov ◽  
Nadya I. Semenischeva ◽  
Elena A. Krasnokutskaya ◽  
Alexei N. Tretyakov ◽  
Ho Yun Hwang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document