scholarly journals (123-124)Theoretical Study on the Temperature Distribution in Self-heat-exchanger-type-reaction Chambers. V. The Temperature Distribution in Parallel-flow-type-reaction Chambers and its Comparison with Counter-flow-type-reaction Chambers.

1949 ◽  
Vol 52 (6) ◽  
pp. 223-224
Author(s):  
Shinjiro Kodama ◽  
Kenichi Fukui ◽  
Kasumi Takagi
2018 ◽  
Vol 16 (2) ◽  
pp. 39
Author(s):  
Syukran Syukran

Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan fluida lain. Pada sebuah penukar panas kemampuan mempertukarkan panas sangat ditentukan oleh tipe dan jenis aliran fluida yang melewati penukar panas. Secara garis besar penukar panas dibagi berdasarkan arah aliran fluidanya. Berdasarkan arah aliran fluida penukar panas  dibedakan menjadi 3 (tiga) jenis aliran, yaitu aliran searah (parallel flow), aliran berlawanan (counter flow) dan aliran silang (cross flow). Saat ini penukar panas banyak dipakai dalam  industri pengeringan produk-produk pertanian, perkebunan dan perikanan skala kecil dan menengah. Penggunaan penukar panas dalam bidang pengeringan saat ini sudah menjadi kebutuhan untuk mengatasi permasalahan produktifitas pengeringan. Umumnya penukar panas yang digunakan adalah tipe aliran berlawanan. Beberapa penelitian telah dilakukan untuk mengetahui efektifitas penukar panas tersebut yang umumnya berfokus pada jenis aliran berlawanan. Penelitian penelitian spesifik yang mengkaji perbandingan efisiensi penukar panas  untuk ketiga jenis aliran belum ditemukan. Penelitian ini dilakukan untuk mengetahui efisiensi temperatur penukar panas untuk jenis aliran jenis aliran melintang, sejajar, dan  berlawanan. Metode penelitian dilakukan fabrikasi 3 unit exchanger tipe gas-gas dengan dimensi 50 (P) x 10 (L) x 30 (T) dengan jumlah tube 17 susunan. Hasil  penelitian menunjukkan bahwa efisiensi temperatur untuk ketiga jenis penukar panas tersebut adalah 21,3% aliran melintang, 17,3% aliran berlawanan dan 15,9%  aliran sejajar. Hasil penelitian menyimpulkan bahwa efisiensi temperatur tertinggi diperoleh jenis penukar panas aliran melintang. Kata kunci : Penukar panas, aliran sejajar, aliran berlawanan, aliran silang, temperatur.  Abstrack Heat exchangers or heat exchangers are the means used to change the temperature of the fluid or to change the fluid phase by exchanging heat with other fluids. In a heat exchanger the heat exchange ability is greatly determined by the type and type of fluid flow passing through the heat exchanger. Broadly speaking the exchanger is divided based on the direction of fluid flow. Based on the direction of fluid flow exchanger is divided into 3 (three) types of flow, namely parallel flow, counter flow and cross flow. Currently, heat exchangers are widely used in the drying industry of small and medium-sized agricultural and small-scale plantation and fishery products. The use of exchangers in the field of drying is now a need to overcome the problems of drying productivity. Generally the exchanger used is the opposite flow type (counter flow). Several studies have been conducted to determine the effectiveness of these exchangers which generally focus on the opposite type of flow. Specific research studies that reviewed the efficiency of exchangers for the three types of flow have not been found. This research was conducted to find out the efficiency of heat exchanger temperature for flow type of cross flow, parallel flow and counter flow type. The research method was fabricated 3 units of gas-gas exchanger type with dimension 50 (P) x 10 (L) x 30 (T) with the number of tubes 17 staggered arrangement. The results show that the temperature efficiency for the three types of heat exchanger is 21.3% cross flow flow, 17.3% flow counter flow and 15.9% parallel flow flow. The results concluded that the highest temperature efficiency obtained by cross flow flow type exchanger. Keywords: Heat exchanger, parallel flow, counter flow, cross flow, temperature


2021 ◽  
Vol 6 (1) ◽  
pp. 69-75
Author(s):  
Taiwo O. Oni ◽  
Ayotunde A. Ojo ◽  
Daniel C. Uguru-Okorie ◽  
David O. Akindele

A shell-and-tube heat exchanger which was subjected to different flow configurations, viz. counter flow, and parallel flow, was investigated. Each of the flow configurations was operated under two different conditions of the shell, that is, an uninsulated shell and a shell insulated with fiber glass. The hot water inlet temperature of the tube was reduced gradually from 60 oC to 40 oC, and performance evaluation of the heat exchanger was carried out. It was found that for the uninsulated shell, the heat transfer effectiveness for hot water inlet temperature of 60, 55, 50, 45, and 40 oC are 0.243, 0.244, 0.240, 0.240, and 0.247, respectively, for the parallel flow arrangement. For the counter flow arrangement, the heat transfer effectiveness for the uninsulated shell are 2.40, 2.74, 5.00, 4.17, and 2.70%, respectively, higher than those for the parallel flow. The heat exchanger’s heat transfer effectiveness with fiber-glass-insulated shell for the parallel flow condition with tube hot water inlet temperatures of 60, 55, 50, 45, and 40 oC are 0.223, 0.226, 0.220, 0.225, and 0.227, respectively, whereas the counter flow condition has its heat transfer effectiveness increased by 1.28, 1.47, 1.82, 1.11, and 1.18%, respectively, over those of the parallel flow.


Sign in / Sign up

Export Citation Format

Share Document