scholarly journals Imaging features of hepatic angiomyolipomas on real-time contrast-enhanced ultrasound

2010 ◽  
Vol 83 (989) ◽  
pp. 411-418 ◽  
Author(s):  
Z Wang ◽  
H-X Xu ◽  
X-Y Xie ◽  
X-H Xie ◽  
M Kuang ◽  
...  
VASA ◽  
2019 ◽  
Vol 48 (2) ◽  
pp. 115-125 ◽  
Author(s):  
Xin Li ◽  
Daniel Staub ◽  
Vasileios Rafailidis ◽  
Mohammed Al-Natour ◽  
Sanjeeva Kalva ◽  
...  

Abstract. Ultrasound has been established as an important diagnostic tool in assessing vascular abnormalities. Standard B-mode and Doppler techniques have inherent limitations with regards to detection of slow flow and small vasculature. Contrast-enhanced ultrasound (CEUS) is a complementary tool and is useful in assessing both the macro- and microvascular anatomy of the aorta. CEUS can also provide valuable physiological information in real-time scanning sessions due to the physical and safety profiles of the administered microbubbles. From a macrovascular perspective, CEUS has been used to characterize aortic aneurysm rupture, dissection and endoleaks post-EVAR repair. With regard to microvasculature CEUS enables imaging of adventitial vasa vasorum thereby assessing aortic inflammation processes, such as monitoring treatment response in chronic periaortitis. CEUS may have additional clinical utility since adventitial vasa vasorum has important implications in the pathogenesis of aortic diseases. In recent years, there have been an increasing number of studies comparing CEUS to cross-sectional imaging for aortic applications. For endoleak surveillance CEUS has been shown to be equal or in certain cases superior in comparison to CT angiography. The recent advancement of CEUS software along with the ongoing development of drug-eluting contrast microbubbles has allowed improved targeted detection and real-time ultrasound guided therapy for aortic vasa vasorum inflammation and neovascularization in animal models. Therefore, CEUS is uniquely suited to comprehensively assess and potentially treat aortic vascular diseases in the future.


2016 ◽  
Vol 41 (10) ◽  
pp. 1973-1979 ◽  
Author(s):  
Zhu Wang ◽  
Wei Wang ◽  
Guang-Jian Liu ◽  
Zheng Yang ◽  
Li-Da Chen ◽  
...  

Circulation ◽  
2001 ◽  
Vol 104 (21) ◽  
pp. 2582-2587 ◽  
Author(s):  
Se-Joong Rim ◽  
Howard Leong-Poi ◽  
Jonathan R. Lindner ◽  
Daniel Couture ◽  
Dilantha Ellegala ◽  
...  

2021 ◽  
Vol 10 ◽  
Author(s):  
Lulu Yang ◽  
Haina Zhao ◽  
Yushuang He ◽  
Xianglan Zhu ◽  
Can Yue ◽  
...  

ObjectiveTo investigate the diagnostic performance of contrast-enhanced ultrasound (CEUS) in the differentiation of primary thyroid lymphoma (PTL) and nodular Hashimoto’s thyroiditis (NHT) in patients with background of heterogeneous diffuse Hashimoto’s thyroiditis (HT).MethodsSixty HT patients with 64 thyroid nodules (31 PTL and 33 NHT) who had undergone CEUS examination were included in this study. With histopathological results as the reference, we evaluated the imaging features of each nodule on both conventional ultrasonography (US) and CEUS. Quantitative CEUS parameters including peak intensity (PI), time to peak (TTP), and area under the time–intensity curve (AUC) were gathered in the nodule and background parenchyma. The ratio indexes of theses parameters were calculated by the ratio of the lesion and the corresponding thyroid parenchyma. Logistic regression and receiver operating characteristic (ROC) curves analyses of valuable US indicators were further preformed to evaluate the diagnostic capability of CEUS in discrimination of PTL and NHT.ResultsAmong all the observed US imaging features and CEUS parameters, 10 indicators showed significant differences between PTL and NHT (all P < 0.05). All the significant indicators were ranked according to the odds ratios (ORs). Eight of them were CEUS associated including imaging features of enhancement pattern, degree, homogeneity, and quantification parameters of PI, AUC, ratios of PI, AUC, and TTP, while indicators on conventional US, including vascularity and size ranked the last two with ORs less than 3. The five single CEUS parameters showed good diagnostic performance in diagnosis of PTL with areas under ROC curves of 0.72–0.83 and accuracies of 70.3–75.0%. The combination of CEUS imaging features and the ratios of PI, AUC, and TTP demonstrated excellent diagnostic efficiency and achieved area under ROC curve of 0.92, which was significantly higher than any of the five single parameters (all P < 0.05), with a sensitivity of 83.9%, specificity of 87.9%, and accuracy of 85.9%.ConclusionsCEUS is an efficient diagnostic tool in the differential diagnosis of PTL and NHT for patients with diffuse HT. Conjoint analysis of CEUS imaging features and quantification parameters could improve the diagnostic values.


2008 ◽  
Vol 27 (4) ◽  
pp. 657-666 ◽  
Author(s):  
Guang-Jian Liu ◽  
Ming-De Lu ◽  
Xiao-Yan Xie ◽  
Hui-Xiong Xu ◽  
Zuo-Feng Xu ◽  
...  

2018 ◽  
Vol 44 (1) ◽  
pp. 310-317 ◽  
Author(s):  
Xiaojing Cao ◽  
Zhenxing Liu ◽  
Xiang Zhou ◽  
Chengyun Geng ◽  
Qing Chang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document