scholarly journals Single-Level Anterior Cervical Corpectomy and Fusion Using a New 3D-Printed Anatomy-Adaptive Titanium Mesh Cage for Treatment of Cervical Spondylotic Myelopathy and Ossification of the Posterior Longitudinal Ligament: A Retrospective Case Series Study

2017 ◽  
Vol 23 ◽  
pp. 3105-3114 ◽  
Author(s):  
Teng Lu ◽  
Chao Liu ◽  
Baohui Yang ◽  
Jiantao Liu ◽  
Feng Zhang ◽  
...  
2021 ◽  
Author(s):  
Yifan Tang ◽  
Fengning Li ◽  
Xiangwu Geng ◽  
Lianshun Jia ◽  
Shengyuan Zhou ◽  
...  

Abstract Background: To analyze risk factors of titanium mesh cage (TMC) subsidence in single-level anterior cervical corpectomy and fusion (ACCF) for cervical ossification of the posterior longitudinal ligament (OPLL). Methods: Patients with cervical OPLL who were treated with single-level ACCF between January 2019 to December 2019 were retrospectively analyzed in two groups: patients with TMC subsidence as Group S, and patients with no TMC subsidence as Group N during the one-year follow-up period. The degree of distraction between decompression of the vertebral bodies and correction of the cervical curvature was measured to analyze their relationship with TMC subsidence. Results: There was no significant difference in patient demographics and complications between the two groups. The degree of distraction in Group S was significantly higher than that in Group N. The change of C2 to C7 Cobb angle (α) in Group S was significantly greater than that in Group N, and the interspinous process distance (SPD) in Group S was also significantly greater than that in Group N. The JOA score and JOA recovery rate were not statistically different between the two groups.Conclusions: Intraoperative selection of overlength TMC in single-level ACCF for OPLL, over-distraction, and excessive correction of the cervical curvature may cause TMC subsidence after surgery. No significant impact of TMC subsidence on the surgical outcome was observed during the 1-year follow-up period.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yuhang Wang ◽  
Yi Zhan ◽  
Huiming Yang ◽  
Hua Guo ◽  
Haiping Zhang ◽  
...  

AbstractFusion with a titanium mesh cage (TMC) has become popular as a conventional method after cervical anterior corpectomy, but postoperative TMC subsidence has often been reported in the literature. We designed a novel anatomic cervical TMC to reduce the postoperative subsidence rate. According to the test process specified in the American Society of Testing Materials (ASTM) F2267 standard, three-dimensional finite element analysis was used to compare the anti-subsidence characteristics of a traditional TMC (TTMC) and novel TMC (NTMC). Through analysis, the relative propensity values of a device to subside (Kp) of the TTMC and NTMC were 665.5 N/mm and 1007.2 N/mm, respectively. A higher Kp measurement is generally expected to indicate that the device is more resistant to subsidence into a vertebral body. The results showed that the novel anatomic titanium mesh cage (NTMC) significantly improved the anti-subsidence performance after anterior cervical corpectomy and fusion (ACCF), which was approximately 51.3% higher than that of the traditional titanium mesh cage.


2021 ◽  
pp. 1-5
Author(s):  
Manavotam Singh ◽  
Keore McKenzie ◽  
Mark L. Hudak ◽  
Anil K. Gehi ◽  
Sunita J. Ferns

Abstract Aim: This retrospective case series study sought to describe the safety and clinical effectiveness of propafenone for the control of arrhythmias in children with and without CHD or cardiomyopathy. Methods: We reviewed baseline characteristics and subsequent outcomes in a group of 63 children treated with propafenone at 2 sites over a 15-year period Therapy was considered effective if no clinically apparent breakthrough episodes of arrhythmias were noted on the medication. Results: Sixty-three patients (29 males) were initiated on propafenone at a median age of 2.3 years. CHD or cardiomyopathy was noted in 21/63 (33%). There were no significant differences between demographics, clinical backgrounds, antiarrhythmic details, side effect profiles, and outcomes between children with normal hearts and children with CHD or cardiomyopathy. Cardiac depression at the initiation of propafenone was more common amongst children with CHD or cardiomyopathy compared to children with normal hearts. Systemic ventricular function was diminished in 15/63 patients (24%) prior to starting propafenone and improved in 8/15 (53%) of patients once better rhythm control was achieved. Other than one child in whom medication was stopped due to gastroesophageal reflux, no other child experienced significant systemic or cardiac side effects during treatment with propafenone. Propafenone achieved nearly equal success in controlling arrhythmias in both children with normal hearts and children with congenital heart disease or cardiomyopathy (90% versus 86%, p = 0.88). Conclusion: Propafenone is a safe and effective antiarrhythmic medication in children.


2017 ◽  
Vol 43 (6) ◽  
pp. 482-490 ◽  
Author(s):  
Aladdin J. Al-Ardah ◽  
Abdulaziz AlHelal ◽  
Periklis Proussaefs ◽  
Bader AlBader ◽  
Abdulakareem A. Al humaidan ◽  
...  

2002 ◽  
Vol 16 (2) ◽  
pp. 105-112 ◽  
Author(s):  
Hiroyuki Nakase ◽  
Yuki Ida ◽  
Rinsei Tei ◽  
Toshisuke Sakaki ◽  
Testuya Morimoto

Sign in / Sign up

Export Citation Format

Share Document