Analysis of vortex induced vibration frequency of super tall building based on wind tunnel tests of MDOF aero-elastic model

2015 ◽  
Vol 21 (5) ◽  
pp. 523-536 ◽  
Author(s):  
Lei Wang ◽  
Shuguo Liang ◽  
Jie Song ◽  
Shuliang Wang
2013 ◽  
Vol 351-352 ◽  
pp. 347-350
Author(s):  
Lun Hai Zhi

This paper present some selected results of wind tunnel tests carried out on a typical super-tall building The variations of wind loads in the three orthogonal directions with wind attack direction were evaluated. The cross-correlations among various wind loading components were presented and discussed in detail. Furthermore, the across-wind spectral characteristics were studied and an empirical formula for estimation of the across-wind overturning moment spectrum for the super-tall building is presented. The output of this study is expected to be of considerable interest and practical use to professionals and researchers involved in the design of super-tall buildings.


2018 ◽  
Vol 22 (4) ◽  
pp. 948-959 ◽  
Author(s):  
Haojun Tang ◽  
KM Shum ◽  
Qiyu Tao ◽  
Jinsong Jiang

To improve the flutter stability of a long-span suspension bridge with steel truss stiffening girder, two vertical stabilizers of which the total height reaches to approximately 2.9 m were planned to install on the deck. As the optimized girder presents the characteristics of a bluff body more, its vortex-induced vibration needs to be studied in detail. In this article, computational fluid dynamics simulations and wind tunnel tests are carried out. The vortex-shedding performance of the optimized girder is analyzed and the corresponding aerodynamic mechanism is discussed. Then, the static aerodynamic coefficients and the dynamic vortex-induced response of the bridge are tested by sectional models. The results show that the vertical stabilizers could make the incoming flow separate and induce strong vortex-shedding behind them, but this effect is weakened by the chord member on the windward side of the lower stabilizer. As the vortex-shedding performance of the optimized girder is mainly affected by truss members whose position relationships change along the bridge span, the vortex shed from the girder can hardly have a uniform frequency so the possibility of vortex-induced vibration of the bridge is low. The data obtained by wind tunnel tests verify the results by computational fluid dynamics simulations.


2022 ◽  
Vol 250 ◽  
pp. 113436
Author(s):  
Yanru Wu ◽  
Xiaohong Wu ◽  
Junxin Li ◽  
Haohui Xin ◽  
Qing Sun ◽  
...  

2014 ◽  
Vol 638-640 ◽  
pp. 1067-1078
Author(s):  
Ting Yang ◽  
Zhi Yong Zhou

To study the mechanism on the vortex resonance characteristics of the central-slotted box girders, the large-scale sectional model vibration measurement and pressure measurement are employed. This paper takes a long-span cable-stayed bridge over the Yangtze River as an example to conduct the wind tunnel tests of large-scale sectional model. The test results indicate that it is the inside maintenance rails located in the aerodynamic susceptible sites that cause the vortex-induced vibration (VIV) of bridge model. Accordingly, the inside maintenance rails are proposed to be moved towards the central axis by a certain distance. The static pressure test results show that when shifting the inside maintenance rails, the negative mean pressure at the soffit plate knuckle line will not change dramatically, the fluctuating pressures on the upwind and downwind inclined panels can be reduced, and the fluctuating energy will be dispersed without a consistent predominant frequency. Wind tunnel tests of modified section are conducted and the results show that the VIV of bridge model can be suppressed completely due to the shift of inside rails.


Sign in / Sign up

Export Citation Format

Share Document