ICOPE-15-C064 Numerical analysis of a single water droplet evaporation caused by laser radiation

2015 ◽  
Vol 2015.12 (0) ◽  
pp. _ICOPE-15--_ICOPE-15-
Author(s):  
Jian-hong CHEN ◽  
Huan-yan HUANG ◽  
De-ren SHENG ◽  
Wei LI
2016 ◽  
Vol 92 ◽  
pp. 01002
Author(s):  
Evgeniy Orlik ◽  
Ekaterina Isachenko

Author(s):  
Linsong Gao ◽  
Jizu Lyu ◽  
Zhifu Zhou ◽  
Yang Li ◽  
Dongdong Gao ◽  
...  

Langmuir ◽  
2013 ◽  
Vol 29 (51) ◽  
pp. 15831-15841 ◽  
Author(s):  
Zhenhai Pan ◽  
Susmita Dash ◽  
Justin A. Weibel ◽  
Suresh V. Garimella

2016 ◽  
Vol 139 (1) ◽  
Author(s):  
Luis A. Ferraz-Albani ◽  
Alberto Baldelli ◽  
Chrissy J. Knapp ◽  
Wolfgang Jäger ◽  
Reinhard Vehring ◽  
...  

Enhancement of water droplet evaporation by added infrared radiation was modeled and studied experimentally in a vertical laminar flow channel. Experiments were conducted on droplets with nominal initial diameters of 50 μm in air with relative humidities ranging from 0% to 90% RH. A 2800 nm laser was used with radiant flux densities as high as 4 × 105 W/m2. Droplet size as a function of time was measured by a shadowgraph technique. The model assumed quasi-steady behavior, a low Biot number liquid phase, and constant gas–vapor phase material properties, while the experimental results were required for model validation and calibration. For radiant flux densities less than 104 W/m2, droplet evaporation rates remained essentially constant over their full evaporation, but at rates up to 10% higher than for the no radiation case. At higher radiant flux density, the surface-area change with time became progressively more nonlinear, indicating that the radiation had diminished effects on evaporation as the size of the droplets decreased. The drying time for a 50 μm water droplet was an order of magnitude faster when comparing the 106 W/m2 case to the no radiation case. The model was used to estimate the droplet temperature. Between 104 and 5 × 105 W/m2, the droplet temperature changed from being below to above the environment temperature. Thus, the direction of conduction between the droplet and the environment also changed. The proposed model was able to predict the changing evaporation rates for droplets exposed to radiation for ambient conditions varying from dry air to 90% relative humidity.


Author(s):  
Tadeusz Orzechowski

Abstract The investigations involved a large water droplet deposited on the heating surface, the temperature of which was higher than the Leidenfrost point. The main element of the experimental setup was the heating cylinder with K-type shielded thermocouple located in its centre just below the surface. The measuring system was located on highly sensitive scales. The analysis of the droplet behaviour in time was conducted based on measured droplet mass changes over time and also photographic data recorded with high resolution digital camera. The energy balance equation is given for the assumption that evaporation from the droplet upper surface is small compared with the amount of heat dissipated from the bottom surface. The formula for the heat transfer coefficient depends on two slope values and an orthogonal projection of the drop onto the heating surface. The slopes are estimated based on the droplet diameter linear time dependence and mass versus the contact zone relationship. The solution provides a good representation of droplet evaporation under Leidenfrost conditions. The investigations, reported in the study, which concern water droplet at atmospheric pressure deposited on a hot surface with the temperature higher than the Leidenfrost point, indicate the following regularities: droplet orthogonal projection onto the heating surface changes linearly with the droplet mass, evaporation of the same amount of mass decreases linearly with an increase in the heating surface temperature, slope of the graph showing mass loss versus the heating surface temperature successively decreases.


2014 ◽  
Vol 6 ◽  
pp. 865856 ◽  
Author(s):  
Roman S. Volkov ◽  
Olga V. Vysokomornaya ◽  
Genii V. Kuznetsov ◽  
Pavel A. Strizhak

The macroscopic regularities of heat and mass transfer and phase transitions during water droplets motion through high-temperature (more than 1000 K) gases have been investigated numerically and experimentally. Water droplet evaporation rates have been established. Gas and water vapors concentrations and also temperature values of gas-vapor mixture in small neighborhood and water droplet trace have been singled out. Possible mechanisms of droplet coagulation in high-temperature gas area have been determined. Experiments have been carried out with the optical methods of two-phase gas-vapor-droplet mixtures diagnostics (“Particle Image Velocimetry” and “Interferometric Particle Imaging”) usage to assess the adequateness of developed heat and mass transfer models and the results of numerical investigations. The good agreement of numerical and experimental investigation results due to integral characteristics of water droplet evaporation has been received.


Sign in / Sign up

Export Citation Format

Share Document