scholarly journals Study on the Leidenfrost Temperature : 1st Report, Experimental Study on the Fundamental Characteristics of the Leidenfrost Temperature

1977 ◽  
Vol 43 (374) ◽  
pp. 3856-3867 ◽  
Author(s):  
Shigefumi NISHIO ◽  
Masaru HIRATA
2003 ◽  
Author(s):  
M. Raudensky´ ◽  
J. Horsky´ ◽  
V. Dumek ◽  
P. Kotrba´cˇek

An experimental study was prepared to find the relationship between Leidenfrost temperature and droplet size and velocity of impinging jets. The study is done for the case of steel surface cooling with two-phase nozzles. The sprayed surface moves under the spray at a velocity of 1 m/min. Cooling experiments were done for initial temperature of 1250°C. Thermal experiments are transient: internal temperature is measured and surface temperature and heat transfer coefficient distribution is computed by the inverse task. Droplet size and velocity of the impinging jet was modified by setting water and air pressures at the input of the nozzle. Spray parameters for each pressure combination was measured using a laser-doppler anemometer. The paper shows the results of the thermal and fluid flow experiment and the correlation between Leidenfrost temperature and flow parameters.The application of obtained results is expected for high temperature cooling especially in continuous casting.


Author(s):  
Norio Baba ◽  
Norihiko Ichise ◽  
Syunya Watanabe

The tilted beam illumination method is used to improve the resolution comparing with the axial illumination mode. Using this advantage, a restoration method of several tilted beam images covering the full azimuthal range was proposed by Saxton, and experimentally examined. To make this technique more reliable it seems that some practical problems still remain. In this report the restoration was attempted and the problems were considered. In our study, four problems were pointed out for the experiment of the restoration. (1) Accurate beam tilt adjustment to fit the incident beam to the coma-free axis for the symmetrical beam tilting over the full azimuthal range. (2) Accurate measurements of the optical parameters which are necessary to design the restoration filter. Even if the spherical aberration coefficient Cs is known with accuracy and the axial astigmatism is sufficiently compensated, at least the defocus value must be measured. (3) Accurate alignment of the tilt-azimuth series images.


1962 ◽  
Vol 5 (4) ◽  
pp. 387-394 ◽  
Author(s):  
Bruce Quarrington ◽  
Jerome Conway ◽  
Nathan Siegel
Keyword(s):  

1974 ◽  
Vol 126 (2) ◽  
pp. 243-248
Author(s):  
A WAKABAYASHI ◽  
T KUBO ◽  
K CHARNEY ◽  
Y NAKAMURA ◽  
J CONNOLLY

1963 ◽  
Vol 45 (3) ◽  
pp. 374-383 ◽  
Author(s):  
Donald C. McIlrath ◽  
George A. Hallenbeck ◽  
Hubert A. Allen ◽  
Charles V. Mann ◽  
Edward J. Baldes ◽  
...  
Keyword(s):  

1958 ◽  
Vol 34 (1) ◽  
pp. 11-20 ◽  
Author(s):  
Henry D. Janowitz ◽  
Vernon A. Weinstein ◽  
Rhoda G. Shaer ◽  
James F. Cereghini ◽  
Franklin Hollander

Sign in / Sign up

Export Citation Format

Share Document