Impingement-free range of movement, acetabular component cover and early clinical results comparing ‘femur-first’ navigation and ‘conventional’ minimally invasive total hip arthroplasty

2015 ◽  
Vol 97-B (7) ◽  
pp. 890-898 ◽  
Author(s):  
T. Renkawitz ◽  
M. Weber ◽  
H-R. Springorum ◽  
E. Sendtner ◽  
M. Woerner ◽  
...  
2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yukihide Minoda ◽  
Ryo Sugama ◽  
Yoichi Ohta ◽  
Susumu Takemura ◽  
Nobuo Yamamoto ◽  
...  

AbstractThe acetabular component orientation in total hip arthroplasty is of critical importance to clinical results. Although navigation systems and surgical robots have been introduced, most surgeons still use acetabular component alignment guides. This study aimed to compare the accuracy between modern acetabular component alignment guides for the lateral position and those for the supine position. Thirteen alignment guides for the lateral position and 10 for the supine position were investigated. All the lateral position alignment guides indicated cup alignment in operative definition, and the supine position alignment guides indicated cup alignment in radiographic definition. For lateral position alignment guides, the anteversion actually indicated by the alignment guide itself was smaller than that indicated by the manufacturer by a mean of 6° (maximum, 9°), and the inclination actually indicated by alignment guides themselves was larger than that by the manufacturer (p < 0.01) by a mean of 2° (maximum, 4°). For supine position alignment guides, the inclination and anteversion indicated by the alignment guide itself were identical with those indicated by the manufacturer. The current study showed that the angles actually indicated and those stated by manufacturers were not identical for lateral position alignment guides.


2020 ◽  
Vol 16 (3) ◽  
pp. 613-620 ◽  
Author(s):  
Paweł Łęgosz ◽  
Sylwia Sarzyńska ◽  
Łukasz Pulik ◽  
Piotr Stępiński ◽  
Paweł Niewczas ◽  
...  

2021 ◽  
pp. 112070002110043
Author(s):  
Antonios A Koutalos ◽  
Sokratis Varitimidis ◽  
Konstantinos N Malizos ◽  
Theofilos Karachalios

Purpose: The aim of the study was to systematically evaluate clinical outcomes of tapered fluted stems, either monoblock or modular, in revision total hip arthroplasty. Methods: PubMed, EMBASE and Web of Science and Cochrane databases were systematically searched by 2 researchers. Clinical studies reporting primarily on survival and re-revision rates, and secondarily on subsidence, dislocation, intraoperative fractures, periprosthetic fractures and infection were included. 2 investigators assessed the quality of the studies. Results: 46 studies were included in this review, reporting on 4601 stem revisions. The pooled re-revision rate was 5.1% and long-term survival ranged from 75% to 98.5%. No differences were observed between monoblock and modular stems regarding re-revision rate, dislocation rate, periprosthetic fracture rate or infection rates. Monoblock stems exhibited more subsidence and modular stems displayed more intraoperative fractures. Conclusions: Satisfactory results can be obtained with the use of tapered fluted end-bearing stems. Monoblock stems offer the same clinical results as modular stems.


Author(s):  
Joel Moktar ◽  
Alan Machin ◽  
Habiba Bougherara ◽  
Emil H Schemitsch ◽  
Radovan Zdero

This study provides the first biomechanical comparison of the fixation constructs that can be created to treat transverse acetabular fractures when using the “gold-standard” posterior versus the anterior approach with and without a total hip arthroplasty in the elderly. Synthetic hemipelvises partially simulating osteoporosis (n = 24) were osteotomized to create a transverse acetabular fracture and then repaired using plates/screws, lag screws, and total hip arthroplasty acetabular components in one of four ways: posterior approach (n = 6), posterior approach plus a total hip arthroplasty acetabular component (n = 6), anterior approach (n = 6), and anterior approach plus a total hip arthroplasty acetabular component (n = 6). All specimens were biomechanically tested. No differences existed between groups for stiffness (range, 324.6–387.3 N/mm, p = 0.629), clinical failure load at 5 mm of femoral head displacement (range, 1630.1–2203.9 N, p = 0.072), or interfragmentary gapping (range, 0.67–1.33 mm, p = 0.359). Adding a total hip arthroplasty acetabular component increased ultimate mechanical failure load for posterior (2904.4 vs. 3652.3 N, p = 0.005) and anterior (3204.9 vs. 4396.0 N, p = 0.000) approaches. Adding a total hip arthroplasty acetabular component also substantially reduced interfragmentary sliding for posterior (3.08 vs. 0.50 mm, p = 0.002) and anterior (2.17 vs. 0.29 mm, p = 0.024) approaches. Consequently, the anterior approach with a total hip arthroplasty may provide the best biomechanical stability for elderly patients, since this fixation group had the highest mechanical failure load and least interfragmentary sliding, while providing equivalent stiffness, clinical failure load, and gapping compared to other surgical options.


2009 ◽  
Vol 24 (8) ◽  
pp. 1216-1220 ◽  
Author(s):  
Kentaro Ise ◽  
Keiichi Kawanabe ◽  
Jiro Tamura ◽  
Haruhiko Akiyama ◽  
Koji Goto ◽  
...  