scholarly journals Mechanical complications and fractures after reverse shoulder arthroplasty related to different design types and their rates: part I

2021 ◽  
Vol 6 (11) ◽  
pp. 1097-1108
Author(s):  
Marko Nabergoj ◽  
Patrick J. Denard ◽  
Philippe Collin ◽  
Rihard Trebše ◽  
Alexandre Lädermann

The initial reverse shoulder arthroplasty (RSA), designed by Paul Grammont, was intended to treat rotator cuff tear arthropathy in elderly patients. In the early experience, high complication rates (up to 24%) and revision rates (up to 50%) were reported. The most common complications reported were scapular notching, whereas clinically more relevant complications such as instability and acromial fractures were less commonly described. Zumstein et al defined a ‘complication’ following RSA as any intraoperative or postoperative event that was likely to have a negative influence on the patient’s final outcome. High rates of complications related to the Grammont RSA design led to development of non-Grammont designs, with 135 or 145 degrees of humeral inclination, multiple options for glenosphere size and eccentricity, improved baseplate fixation which facilitated glenoid-sided lateralization, and the option of humeral-sided lateralization. Improved implant characteristics combined with surgeon experience led to a dramatic fall in the majority of complications. However, we still lack a suitable solution for several complications, such as acromial stress fracture. Cite this article: EFORT Open Rev 2021;6:1097-1108. DOI: 10.1302/2058-5241.6.210039

Author(s):  
Eleanor G. Burden ◽  
Timothy J. Batten ◽  
Christopher D. Smith ◽  
Jonathan P. Evans

Aims This systematic review asked which patterns of complications are associated with the three reverse total shoulder arthroplasty (RTSA) prosthetic designs, as classified by Routman et al, in patients undergoing RTSA for the management of cuff tear arthropathy, massive cuff tear, osteoarthritis, and rheumatoid arthritis. The three implant design philosophies investigated were medial glenoid/medial humerus (MGMH), medial glenoid/lateral humerus (MGLH), and lateral glenoid/medial humerus (LGMH). Methods A systematic review of the literature was performed via a search of MEDLINE and Embase. Two reviewers extracted data on complication occurrence and patient-reported outcome measures (PROMs). Meta-analysis was conducted on the reported proportion of complications, weighted by sample size, and PROMs were pooled using the reported standardized mean difference (SMD). Quality of methodology was assessed using Wylde’s non-summative four-point system. The study was registered with PROSPERO (CRD42020193041). Results A total of 42 studies met the inclusion and exclusion criteria. Rates of scapular notching were found to be significantly higher in MGMH implants (52% (95% confidence interval (CI) 40 to 63)) compared with MGLH ((18% (95% CI 6 to 34)) and LGMH (12% (95% CI 3 to 26)). Higher rates of glenoid loosening were seen in MGMH implants (6% (95% CI 3 to 10)) than in MGLH implants (0% (95% CI 0 to 2)). However, strength of evidence for this finding was low. No significant differences were identified in any other complication, and there were no significant differences observed in PROMs between implant philosophies. Conclusion This systematic review has found significant improvement in PROMS and low complication rates across the implant philosophies studied. Scapular notching was the only complication found definitely to have significantly higher prevalence with the MGMH implant design.


2020 ◽  
Vol 15 (3) ◽  
pp. 207-212
Author(s):  
Patric Raiss ◽  
Rainer Neumann

Abstract Introduction Reverse shoulder arthroplasty (RSA) has become a well-established treatment option for multiple disorders of the shoulder joint. In recent years, implant designs and configurations have been modified in order to improve function and avoid complications. Lateralization on the glenoid and the humeral side has been described to improve function and decrease radiographic scapular notching. Data on the clinical and radiographic results of bipolar lateralization in RSA are lacking. Methods In 38 cases, RSA was performed using an uncemented humeral short-stem component with a 145° neck–shaft angle in combination with bone lateralization on the glenoid side (Bony Increased-Offset Reversed Shoulder Arthroplasty, BIO-RSA; Wright Medical Inc., Memphis, TN, USA). Mean follow-up was 19 months (range 12–34 months). Patients were followed clinically using the Constant score as well as range of motion for shoulder flexion and external rotation. Radiographs in two different plains were analyzed for implant seating and the occurrence of scapular notching. Results There was a significant increase in all measured clinical parameters. Forward flexion increased from a mean of 75° preoperatively to 151° postoperatively, and mean Constant score increased from 21 to 71 points postoperatively (p < 0.001). Glenoid notching of grade 1 according to Sirveuax was observed in 3 out of 35 cases (9%); no grade 2, 3, or 4 notching was present. Revision surgery was necessary in one case (3%). Conclusion RSA with bipolar lateralization leads to excellent clinical outcomes, low complication rates, and low rates of radiographic scapular notching. Longer follow-up and prospective randomized trials are needed. Level of evidence Level IV.


2009 ◽  
Vol 33 (2) ◽  
pp. 167-172 ◽  
Author(s):  
Filippo Castoldi ◽  
Nicola Lollino ◽  
Francesco Caranzano ◽  
Marco Assom

We present a case report of a patient, affected by post-polio syndrome and cuff tear arthropathy of his right shoulder, who underwent reverse shoulder arthroplasty. A previous radial deficiency was unmasked in the post-operative follow-up, with passive elbow bending when the forearm was put in an antigravitational position. A precise preoperative neurological evaluation is mandatory in shoulder replacement in order to estimate the functional outcome after surgery.