scholarly journals Hip implants can restore anatomical and medialized rotation centres in most cases

2021 ◽  
Vol 2 (7) ◽  
pp. 476-485
Author(s):  
Thierry Scheerlinck ◽  
Elien De Winter ◽  
Amelie Sas ◽  
Sjoerd Kolk ◽  
Gert Van Gompel ◽  
...  

Aims Hip arthroplasty does not always restore normal anatomy. This is due to inaccurate surgery or lack of stem sizes. We evaluated the aptitude of four total hip arthroplasty systems to restore an anatomical and medialized hip rotation centre. Methods Using 3D templating software in 49 CT scans of non-deformed femora, we virtually implanted: 1) small uncemented calcar-guided stems with two offset options (Optimys, Mathys), 2) uncemented straight stems with two offset options (Summit, DePuy Synthes), 3) cemented undersized stems (Exeter philosophy) with three offset options (CPT, ZimmerBiomet), and 4) cemented line-to-line stems (Kerboul philosophy) with proportional offsets (Centris, Mathys). We measured the distance between the templated and the anatomical and 5 mm medialized hip rotation centre. Results Both rotation centres could be restored within 5 mm in 94% and 92% of cases, respectively. The cemented undersized stem performed best, combining freedom of stem positioning and a large offset range. The uncemented straight stem performed well because of its large and well-chosen offset range, and despite the need for cortical bone contact limiting stem positioning. The cemented line-to-line stem performed less well due to a small range of sizes and offsets. The uncemented calcar-guided stem performed worst, despite 24 sizes and a large and well-chosen offset range. This was attributed to the calcar curvature restricting the stem insertion depth along the femoral axis. Conclusion In the majority of non-deformed femora, leg length, offset, and anteversion can be restored accurately with non-modular stems during 3D templating. Failure to restore hip biomechanics is mostly due to surgical inaccuracy. Small calcar guided stems offer no advantage to restore hip biomechanics compared to more traditional designs. Cite this article: Bone Jt Open 2021;2(7):476–485.

2020 ◽  
Vol 28 (1) ◽  
pp. 230949902090949
Author(s):  
Tomofumi Nishino ◽  
Hajime Mishima ◽  
Haruo Kawamura ◽  
Tomohiro Yoshizawa ◽  
Shumpei Miyakawa ◽  
...  

Purpose: In developmental dysplasia of the hip (DDH), the centers of hip rotation move in the superior and lateral direction. In total hip arthroplasty for such cases, movement of the center of hip rotation is in the inferior and medial direction. It causes an increase in leg length and a decrease in acetabular offset. We therefore evaluated the change of hip offset and leg length before and after surgery with two stems having a high offset option. Patients and Methods: The preoperative diagnosis was secondary osteoarthritis due to DDH excluded Crowe IV. A stem selection was decided based on preoperative two-dimensional templating. Total 55 hips in 50 patients were followed up for minimum 10 years. Pre- and postoperative clinical evaluations were performed using a hip joint function scoring system. Radiographic evaluations were used for offset and leg length measurements and other associated factors. Results: Both stems showed excellent clinical results. A high offset option was used in 60% of all cases. No postoperative dislocations were observed. The biological fixation was stable in all cases. The hip offset was restored without excessive leg lengthening in most cases. Conclusion: Anatomical consistency could be maintained by using a stem which matched geometry of the proximal part and had offset option. These cementless tapered stems having a high offset option are suitable for Crowe I to III hip dysplasia if two-dimensional X-ray templates fit the shape of the proximal femurs. They were associated with excellent clinical results and biological fixation. The offset option may be useful to adjust leg length and offset in DDH patients.


Author(s):  
Han-Jun Lee ◽  
Seong Hwan Kim ◽  
Nicolas Pujol ◽  
Yong-Beom Park

AbstractThe purpose of this study is to compare perception of leg length discrepancy (LLD) and clinical results of total knee arthroplasties (TKA) in patients with or without previous ipsilateral hip arthroplasty. Between 2008 and 2015, navigation-assisted TKA was performed in 43 patients with previous hip arthroplasty after hip fracture. After 1:3 propensity score matching was performed, 108 patients of primary navigation-assisted TKA (group 1) and 36 patients with hip arthroplasty (group 2) were included. Knee Society (KS) scores, Western Ontario and McMaster Universities Index (WOMAC) scores, and patients' satisfaction including perception of LLD were evaluated. Radiographic evaluation included mechanical axis, component position, and LLD. Logistic regression analysis was performed to find the factors that affect the clinical outcomes. No significant differences in radiologic and clinical evaluations, except for KS function score, patient's satisfaction and LLD (p< 0.001), were detected between the groups. LLD and its perception were significantly higher in group 2 (1.8 ± 3.4 mm in group 1 and 9.7 ± 4.1 mm in group 2, p = 0.000). Risk factors for the low KS function score were found as LLD (odds ratio [OR]: 1.403, p = 0.008) and previous hip arthroplasty itself (OR: 15.755, p = 0.002), but much higher OR was found in previous hip arthroplasty. Although the outcomes of TKA in patients with ipsilateral hip arthroplasty are comparable to those of primary TKA, LLD was high and patient's satisfaction and functional outcomes were low in patients with previous ipsilateral hip arthroplasty. Care should be taken when considering TKA in patients with previous hip arthroplasty. This is a Level III, case control study.


2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Y. Knafo ◽  
F. Houfani ◽  
B. Zaharia ◽  
F. Egrise ◽  
I. Clerc-Urmès ◽  
...  

Two-dimensional (2D) planning on standard radiographs for total hip arthroplasty may not be sufficiently accurate to predict implant sizing or restore leg length and femoral offset, whereas 3D planning avoids magnification and projection errors. Furthermore, weightbearing measures are not available with computed tomography (CT) and leg length and offset are rarely checked postoperatively using any imaging modality. Navigation can usually achieve a surgical plan precisely, but the choice of that plan remains key, which is best guided by preoperative planning. The study objectives were therefore to (1) evaluate the accuracy of stem/cup size prediction using dedicated 3D planning software based on biplanar radiographic imaging under weightbearing and (2) compare the preplanned leg length and femoral offset with the postoperative result. This single-centre, single-surgeon prospective study consisted of a cohort of 33 patients operated on over 24 months. The routine clinical workflow consisted of preoperative biplanar weightbearing imaging, 3D surgical planning, navigated surgery to execute the plan, and postoperative biplanar imaging to verify the radiological outcomes in 3D weightbearing. 3D planning was performed with the dedicated hipEOS® planning software to determine stem and cup size and position, plus 3D anatomical and functional parameters, in particular variations in leg length and femoral offset. Component size planning accuracy was 94% (31/33) within one size for the femoral stem and 100% (33/33) within one size for the acetabular cup. There were no significant differences between planned versus implanted femoral stem size or planned versus measured changes in leg length or offset. Cup size did differ significantly, tending towards implanting one size larger when there was a difference. Biplanar radiographs plus hipEOS planning software showed good reliability for predicting implant size, leg length, and femoral offset and postoperatively provided a check on the navigated surgery. Compared to previous studies, the predictive results were better than 2D planning on conventional radiography and equal to 3D planning on CT images, with lower radiation dose, and in the weightbearing position.


Author(s):  
Bjoern Vogt ◽  
Christoph Theil ◽  
Georg Gosheger ◽  
Adrien Frommer ◽  
Burkhard Moellenbeck ◽  
...  

Abstract Background and purpose Total hip arthroplasty (THA) is a successful approach to treat unilateral symptomatic neglected hip dislocation (NHD). However, the extensive leg length discrepancy (LLD) can hereby only be partially corrected. In case of residual LLD of more than 2 cm, subsequent femoral lengthening can be considered. Patients/material/methods Retrospective analysis of clinical data and radiographs of five patients (age 38.1 (28–51) years) with unilateral NHD who underwent THA with (n  = 3) or without (n = 2) subtrochanteric shortening osteotomy (SSO) and secondary intramedullary femoral lengthening through a retrograde magnetically-driven lengthening nail (follow-up 18.4 (15–27) months). Results LLD was 51.0 (45–60) mm before and 37.0 (30–45) mm after THA. Delayed bone union at one SSO site healed after revision with autologous bone grafting and plate fixation. Subsequent lengthening led to leg length equalisation in all patients. Complete consolidation was documented in all lengthened segments. Conclusion Staged reconstruction via THA and secondary femoral lengthening can successfully be used to reconstruct the hip joint and equalise LLD. The specific anatomical conditions have to be taken into consideration when planning treatment, and patients ought to be closely monitored.


Author(s):  
Kentaro Iwakiri ◽  
Yoichi Ohta ◽  
Takashi Fujii ◽  
Yukihide Minoda ◽  
Akio Kobayashi ◽  
...  

2009 ◽  
Vol 5 (2) ◽  
pp. 192-197 ◽  
Author(s):  
Tobias Renkawitz ◽  
Tibor Schuster ◽  
Thomas Herold ◽  
Holger Goessmann ◽  
Ernst Sendtner ◽  
...  

2021 ◽  
Vol 10 (6) ◽  
pp. 1235
Author(s):  
Michael Fuchs ◽  
Marie-Anne Hein ◽  
Martin Faschingbauer ◽  
Mirco Sgroi ◽  
Ralf Bieger ◽  
...  

Because of preservation of proximal femoral bone stock and minimized soft tissue trauma, short-stem implants are becoming increasingly important in total hip arthroplasty (THA). The postulated advantage regarding the functional outcome has not been verified. We hypothesized an increased abductor muscle strength by the use of a short-stem design. Seventy consecutive patients of a randomized clinical trial were included. Of these, 67 patients met the inclusion criteria after 12 months. Thirty-five patients received a standard straight stem and 32 patients a short-stem femoral component. All surgeries were performed by a modified direct lateral approach. Isometric muscle strength of the hip abductors was evaluated preoperatively 3 and 12 months after surgery. Harris hip score (HHS) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were evaluated. After three months, there were no differences between the two groups; the abductor force was comparable to the preoperative initial values. After 12 months, a significant increase in muscle strength for the short stem patient group compared to preoperative baseline values was measured (straight-stem THA, 0.09 Nm/kg ± 0.4, p = 0.32; short-stem THA, 0.2 Nm/kg ± 0.3, p = 0.004). Comparison of the 12-month postoperative total HHS and WOMAC revealed no significant differences between both groups. A significant increase in hip abductor muscle strength 12 months after short-stem THA compared to conventional-stem THA was observed.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Georg Hauer ◽  
Maria Smolle ◽  
Sabrina Zaussinger ◽  
Joerg Friesenbichler ◽  
Andreas Leithner ◽  
...  

AbstractReturn to work (RTW) has been specifically identified as a high priority in patients undergoing total hip arthroplasty (THA). This investigation sought to assess the effect of the stem design on patients’ RTW. Secondly, the study aimed to identify risk factors that lead to a delayed RTW. Questionnaires inquiring about RTW, employment history, educational level, type of work, physical demands and joint awareness were administered by post. Further data were collected from patients’ hospital records. 176 patients who underwent THA using a short-stem and 97 patients using a straight-stem design were compared. The median return to work time was 10 weeks [IQR 7–14 weeks], with no significant difference between the two groups (short stems vs. straight stems; 10 [IQR 7–14] vs. 11 [7.5–13.5] weeks; p = 0.693). In the multivariate linear regression analysis, self-employment vs. employee (p = 0.001), dimension of preoperative workload (p = 0.001), preoperative sick leave (p < 0.001), and hospital length of stay (LOS) (p < 0.001) independently affected the period until work was resumed. The Forgotten-Joint-Score-12 showed no significant difference between the two groups. The data show that the majority of THA patients can expect to resume work and stem design has no impact on RTW. Employees with preoperative sick leave, prolonged hospital LOS and low workload are at higher risk for a delayed RTW.


2018 ◽  
Vol 33 (1) ◽  
pp. 156-161 ◽  
Author(s):  
Moritz M. Innmann ◽  
Michael W. Maier ◽  
Marcus R. Streit ◽  
George Grammatopoulos ◽  
Thomas Bruckner ◽  
...  