Recent Calculation Results for a Fission-Fusion System with Gas Dynamic Trap Neutron Source

2013 ◽  
Vol 63 (1T) ◽  
pp. 313-315 ◽  
Author(s):  
D. V. Yurov ◽  
S. A. Brednikhin ◽  
S. A. Frolov ◽  
S. I. Lezhnin ◽  
V. V. Prikhodko ◽  
...  

2021 ◽  
Vol 11 (11) ◽  
pp. 4990
Author(s):  
Boris Benderskiy ◽  
Peter Frankovský ◽  
Alena Chernova

This paper considers the issues of numerical modeling of nonstationary spatial gas dynamics in the pre-nozzle volume of the combustion chamber of a power plant with a cylindrical slot channel at the power plant of the mass supply surface. The numerical simulation for spatial objects is based on the solution conjugate problem of heat exchange by the control volume method in the open integrated platform for numerical simulation of continuum mechanics problems (openFoam). The calculation results for gas-dynamic and thermal processes in the power plant with a four-nozzle cover are presented. The analysis of gas-dynamic parameters and thermal flows near the nozzle cover, depending on the canal geometry, is given. The topological features of the flow structure and thermophysical parameters near the nozzle cap were studied. For the first time, the transformation of topological features of the flow structure in the pre-nozzle volume at changes in the mass channel’s geometry is revealed, described, and analyzed. The dependence of the Nusselt number in the central point of stagnation on the time of the power plants operation is revealed.


1999 ◽  
Vol 35 (1T) ◽  
pp. 195-199 ◽  
Author(s):  
V.V. Korshakov ◽  
V.G. Krasnoperov ◽  
A.A. Ivanov ◽  
Yu.A. Tsidulko ◽  
G.I. Budker

2021 ◽  
Vol 2057 (1) ◽  
pp. 012004
Author(s):  
Yu A Borisov ◽  
V V Volkov-Muzilev ◽  
D A Kalashnikov ◽  
H S Khalife

Abstract The article discusses the issues of reducing the size of the cooling unit of the antenna of a radar station by improving the gas-dynamic processes occurring in the air-cooling unit. The results of the experimental studies of the gas flow in a plate-fin heat exchanger, being blown by one axial fan are presented. The feasibility of changing the number of axial fans for organizing a more uniform flow around the heat-exchange surfaces has been determined by calculation and theoretical methods. The calculation results are confirmed by experimental studies of the air flow in the segment of the heat exchanger, which is provided by a smaller fan.


2020 ◽  
Vol 60 (6) ◽  
pp. 067001
Author(s):  
I. Kotelnikov ◽  
Z. Chen ◽  
P. Bagryansky ◽  
A. Sudnikov ◽  
Q. Zeng ◽  
...  

2010 ◽  
Vol 57 (4) ◽  
pp. 369-394 ◽  
Author(s):  
A. Molvik ◽  
A. Ivanov ◽  
G. L. Kulcinski ◽  
D. Ryutov ◽  
J. Santarius ◽  
...  

1999 ◽  
Vol 35 (1T) ◽  
pp. 160-164 ◽  
Author(s):  
U. Fischer ◽  
A. Möslang ◽  
A. A. Ivanov
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document