scholarly journals Burst-mode OH/CH2O planar laser-induced fluorescence imaging of the heat release zone in an unsteady flame

2018 ◽  
Vol 26 (14) ◽  
pp. 18105 ◽  
Author(s):  
Ulrich Retzer ◽  
Rongchao Pan ◽  
Thomas Werblinski ◽  
Franz J. T. Huber ◽  
Mikhail N. Slipchenko ◽  
...  
1998 ◽  
Vol 27 (2) ◽  
pp. 2069-2076 ◽  
Author(s):  
David F. Marran ◽  
Marshall B. Long ◽  
William M. Studzinski ◽  
J. Christian Swindal ◽  
William P. Acker

2018 ◽  
Vol 10 (3) ◽  
pp. 185-210 ◽  
Author(s):  
Ruoyang Yuan ◽  
James Kariuki ◽  
Epaminondas Mastorakos

Various characteristics of swirling spray flames of ethanol, n-heptane, n-decane, and n-dodecane have been measured at conditions far from and close to blow-off using phase Doppler anemometry and OH* chemiluminescence, OH-planar laser-induced fluorescence, and Mie scattering at 5 kHz. The blow-off transient has also been examined. The OH* showed that the two main heat release regions lie around the spray jet at the inner recirculation zone and along the outer shear layer between the inner recirculation zone and the annular air jet. The heat release region is shortened and more attached as the flame approached blow-off. Mie images and phase Doppler anemometry data showed a wider dispersion of the ethanol spray compared to the other fuels. Similar spatial distributions of the Sauter mean diameter were observed for the four fuels for identical flow conditions, with the Sauter mean diameter value increasing with decreasing fuel volatility, but with the exception of significant presence of droplets in the nominally hollow cone for the ethanol spray. The OH-planar laser-induced fluorescence measurements showed an intermittent lift-off from the corner of the bluff body and the average lift-off height decreased with increasing air velocity, with less extinction along the inner flame branch especially for the heavier fuels. At the blow-off conditions, local extinctions appeared at both flame branches. The blow-off process followed a gradual reduction of the size of the flame, with the less volatile fuels showing a more severe flame area reduction compared to the condition far from blow-off. The average blow-off duration, [Formula: see text], calculated from the evolution of the area-integrated OH* signal, was a few tens of milliseconds and for all conditions investigated the ratio [Formula: see text] /( D/ UB) was around 11, but with large scatter. The measurements provide useful information for validation of combustion models focusing on local and global extinction.


2020 ◽  
Vol 45 (20) ◽  
pp. 5776
Author(s):  
Paul S. Hsu ◽  
Mikhail N. Slipchenko ◽  
Naibo Jiang ◽  
Christopher A. Fugger ◽  
Austin M. Webb ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document