scholarly journals Post-Heparin LPL Activity Measurement Using VLDL As a Substrate: A New Robust Method for Routine Assessment of Plasma Triglyceride Lipolysis Defects

PLoS ONE ◽  
2014 ◽  
Vol 9 (5) ◽  
pp. e96482 ◽  
Author(s):  
Mathilde Di Filippo ◽  
Christophe Marçais ◽  
Sybil Charrière ◽  
Oriane Marmontel ◽  
Martine Broyer ◽  
...  
1983 ◽  
Vol 50 (02) ◽  
pp. 563-566 ◽  
Author(s):  
P Hellstern ◽  
K Schilz ◽  
G von Blohn ◽  
E Wenzel

SummaryAn assay for rapid factor XIII activity measurement has been developed based on the determination of the ammonium released during fibrin stabilization. Factor XIII was activated by thrombin and calcium. Ammonium was measured by an ammonium-sensitive electrode. It was demonstrated that the assay procedure yields accurate and precise results and that factor XIII-catalyzed fibrin stabilization can be measured kinetically. The amount of ammonium released during the first 90 min of fibrin stabilization was found to be 7.8 ± 0.5 moles per mole fibrinogen, which is in agreement with the findings of other authors. In 15 normal subjects and in 15 patients suffering from diseases with suspected factor XIII deficiency there was a satisfactory correlation between the results obtained by the “ammonium-release-method”, Bohn’s method, and the immunological assay (r1 = 0.65; r2= 0.70; p<0.01). In 3 of 5 patients with paraproteinemias the values of factor XIII activity determined by the ammonium-release method were markedly lower than those estimated by the other methods. It could be shown that inhibitor mechanisms were responsible for these discrepancies.


1995 ◽  
Vol 15 (5) ◽  
pp. 714-720 ◽  
Author(s):  
Marie-Claude Vohl ◽  
Benoı̂t Lamarche ◽  
Sital Moorjani ◽  
Denis Prud’homme ◽  
André Nadeau ◽  
...  

Synthesis ◽  
2019 ◽  
Vol 52 (02) ◽  
pp. 311-319
Author(s):  
Austin D. Marchese ◽  
Bijan Mirabi ◽  
Egor M. Larin ◽  
Mark Lautens

A Ni-catalyzed C–S cross-coupling using only NiI2 (0.5–2.5 mol%) and P(OiPr)3 (2.0–10.0 mol%) is reported. Using an air-stable Ni(II) precatalyst, and a cheap and commercially available ligand, a scalable and robust method was developed to cross-couple various thiophenols and styryl bromides, including some sterically encumbered thiols, an α-bromocinnamaldehyde as well as a thiolation-cyclization.


Trials ◽  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Mingcai Zhang ◽  
Guoqing Du ◽  
Congying Liu ◽  
Wei Li ◽  
Jiayu Yang ◽  
...  

Abstract Background Neck pain is a common clinical disease, which seriously affects people’s mental health and quality of life and results in loss of social productivity. Improving neck pain’s curative effect and reducing its recurrence rate are major medical problems. Shi’s manipulation therapy has unique advantages and technical features that aid in the diagnosis and treatment of neck pain. Compared with first-line non-steroidal anti-inflammatory drug (NSAID) treatment of neck pain, Shi’s cervical manipulation lacks the relevant research basis of therapeutic advantage, safety, and satisfaction for treating acute and subacute neck pain. Herein, we aim to confirm our hypothesis in a clinical trial that the safety and efficacy of Shi’s cervical manipulation will be more effective, safer, and more satisfactory than NSAIDs to treat acute and subacute neck pain. Methods In this multicenter, positive-controlled, randomized clinical trial, traditional analgesic drug (NSAID) is used to evaluate and show that Shi’s manipulation is more effective, safe, and satisfactory for treating acute and subacute neck pain. Overall, 240 subjects are randomly divided into the trial and control groups, with both groups treated by the corresponding main intervention method for up to 12 weeks. Clinical data will be collected before the intervention and immediately after the first treatment; at 3 days and 1, 2, 4, 8, and 12 weeks after the intervention; and at 26 and 52 weeks after treatment follow-up of clinical observation index data collection. The clinical observation indices are as follows: (1) cervical pain is the primary observation index, measured by Numerical Rating Scale. The secondary indices include the following: (2) cervical dysfunction index, measured by patient self-evaluation using cervical Neck Disability Index; (3) cervical activity measurement, measured by the cervical vertebra mobility measurement program of Android mobile phone system; (4) overall improvement, measured by patient self-evaluation with SF-36; and (5) satisfactory treatment, determined by patient self-evaluation. Discussion We will discuss whether Shi’s cervical manipulation has greater advantages in efficacy, safety, and satisfaction of acute and subacute neck pain than traditional NSAIDs, to provide a scientific basis for the dissemination and application of Shi’s cervical manipulation. Trial registration China Registered Clinical Trial Registration Center ChiCTR1900021371. Registered on 17 February 2019


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ryan Kozak ◽  
Kasra Khorsand ◽  
Telnaz Zarifi ◽  
Kevin Golovin ◽  
Mohammad H. Zarifi

AbstractA patch antenna sensor with T-shaped slots operating at 2.378 GHz was developed and investigated for wireless ice and frost detection applications. Detection was performed by monitoring the resonant amplitude and resonant frequency of the transmission coefficient between the antenna sensor and a wide band receiver. This sensor was capable of distinguishing between frost, ice, and water with total shifts in resonant frequency of 32 MHz and 36 MHz in the presence of frost and ice, respectively, when compared to the bare sensor. Additionally, the antenna was sensitive to both ice thickness and the surface area covered in ice displaying resonant frequency shifts of 2 MHz and 8 MHz respectively between 80 and 160 μL of ice. By fitting an exponential function to the recorded data, the freezing rate was also extracted. The analysis within this work distinguishes the antenna sensor as a highly accurate and robust method for wireless ice accretion detection and monitoring. This technology has applications in a variety of industries including the energy sector for detection of ice on wind turbines and power lines.


2021 ◽  
Vol 108 (Supplement_2) ◽  
Author(s):  
B Hughes ◽  
J Stallard ◽  
S Jivan

Abstract Introduction Surgical drains are used by many specialities, we aim to determine the most robust method of securing them by comparing suturing technique, material and fixation angle. Method A Blake’s drain was inserted into a piece of pork belly and secured using a standard ‘three half hitch’ technique with 3.0 Silk, EthilonTM and ProleneTM . For each suture type, drains were sutured in line, at 45 and 90 degrees to the course of the drain. The force needed for the suture to failure was measured and each repeated 3 times. Different suture techniques were then used to determine the strongest fixation. Results With the drain exiting inline the moment of failure was, on average, 1.25kg for silk, 3.5kg for EthilonTM and 4.0kg for ProleneTM. Increasing drain fixation angle required more force for the suture to fail. With EthilonTM and ProleneTM, the suture snapped before the drain slipped. Three half hitches was the strongest technique. Conclusions Suture material, technique and drain fixation angle had an impact on suture strength with ProleneTM outperforming Silk. We advocate using a ‘three half hitch’ technique with 3.0 ProleneTM to secure a surgical drain. It offers superior strength whilst reducing the risk of localised tissue reactions.