tissue reactions
Recently Published Documents


TOTAL DOCUMENTS

823
(FIVE YEARS 125)

H-INDEX

55
(FIVE YEARS 5)

Author(s):  
Yesenia Gómez Taborda ◽  
Maryory Gómez Botero ◽  
Juan Guillermo Castaño-González ◽  
Angela Bermúdez-Castañeda

During their service life, modular interfaces experience tribological, and corrosion phenomena that lead to deterioration, which in turn can cause a revision procedure to remove the failed prosthesis. To achieve a clearer understanding of the surface performance of those biomedical alloys and the role of the surface properties in the mechanical and chemical performance, samples were taken from retrieval implants made of Ti6Al4V and Co28Cr6Mo alloys. Polarization resistance and pin-on-disk tests were performed on these samples. Physical properties such as contact angle, roughness, microhardness, and Young’s modulus were determined. A correlation between surface energy and evolution of the tribological contact was observed for both biomedical alloys. In tribocorrosion tests, titanium particles seem to remain in the surface, unlike what is observed in CoCr alloys. These metallic or oxidized particles could cause necrosis or adverse tissue reactions.


2021 ◽  
Author(s):  
Tsunehito Ishida ◽  
Toshiyuki Tateiwa ◽  
Yasuhito Takahashi ◽  
Yohei Nishikawa ◽  
Takaaki Shishido ◽  
...  

2021 ◽  
Vol 8 (12) ◽  
pp. 204
Author(s):  
Nor Azila Abd. Wahid ◽  
Azadeh Hashemi ◽  
John J. Evans ◽  
Maan M. Alkaisi

Culture platform surface topography plays an important role in the regulation of biological cell behaviour. Understanding the mechanisms behind the roles of surface topography in cell response are central to many developments in a Lab on a Chip, medical implants and biosensors. In this work, we report on a novel development of a biocompatible conductive hydrogel (CH) made of poly (3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) and gelatin with bioimprinted surface features. The bioimprinted CH offers high conductivity, biocompatibility and high replication fidelity suitable for cell culture applications. The bioimprinted conductive hydrogel is developed to investigate biological cells’ response to their morphological footprint and study their growth, adhesion, cell–cell interactions and proliferation as a function of conductivity. Moreover, optimization of the conductive hydrogel mixture plays an important role in achieving high imprinting resolution and conductivity. The reason behind choosing a conducive hydrogel with high resolution surface bioimprints is to improve cell monitoring while mimicking cells’ natural physical environment. Bioimprints which are a 3D replication of cellular morphology have previously been shown to promote cell attachment, proliferation, differentiation and even cell response to drugs. The conductive substrate, on the other hand, enables cell impedance to be measured and monitored, which is indicative of cell viability and spread. Two dimensional profiles of the cross section of a single cell taken via Atomic Force Microscopy (AFM) from the fixed cell on glass, and its replicas on polydimethylsiloxane (PDMS) and conductive hydrogel (CH) show unprecedented replication of cellular features with an average replication fidelity of more than 90%. Furthermore, crosslinking CH films demonstrated a significant increase in electrical conductivity from 10−6 S/cm to 1 S/cm. Conductive bioimprints can provide a suitable platform for biosensing applications and potentially for monitoring implant-tissue reactions in medical devices.


2021 ◽  
Vol 15 ◽  
Author(s):  
Abdel-Hameed Dabbour ◽  
Sheryl Tan ◽  
Sang Ho Kim ◽  
Sarah-Jane Guild ◽  
Peter Heppner ◽  
...  

Technological advancements in electronics and micromachining now allow the development of discrete wireless brain implantable micro-devices. Applications of such devices include stimulation or sensing and could enable direct placement near regions of interest within the brain without the need for electrode leads or separate battery compartments that are at increased risk of breakage and infection. Clinical use of leadless brain implants is accompanied by novel risks, such as migration of the implant. Additionally, the encapsulation material of the implants plays an important role in mitigating unwanted tissue reactions. These risks have the potential to cause harm or reduce the service of life of the implant. In the present study, we have assessed post-implantation tissue reaction and migration of borosilicate glass-encapsulated micro-implants within the cortex of the brain. Twenty borosilicate glass-encapsulated devices (2 × 3.5 × 20 mm) were implanted into the parenchyma of 10 sheep for 6 months. Radiographs were taken directly post-surgery and at 3 and 6 months. Subsequently, sheep were euthanized, and GFAP and IBA-1 histological analysis was performed. The migration of the implants was tracked by reference to two stainless steel screws placed in the skull. We found no significant difference in fluoroscopy intensity of GFAP and a small difference in IBA-1 between implanted tissue and control. There was no glial scar formation found at the site of the implant’s track wall. Furthermore, we observed movement of up to 4.6 mm in a subset of implants in the first 3 months of implantation and no movement in any implant during the 3–6-month period of implantation. Subsequent histological analysis revealed no evidence of a migration track or tissue damage. We conclude that the implantation of this discrete micro-implant within the brain does not present additional risk due to migration.


2021 ◽  
Vol 6 (12) ◽  
pp. 1132-1139
Author(s):  
Lorenz Pisecky ◽  
Matthias Luger ◽  
Antonio Klasan ◽  
Tobias Gotterbarm ◽  
Matthias C. Klotz ◽  
...  

Bioabsorbable and biodegradable implants offer new possibilities in orthopaedic and trauma surgery. As soon as the initial stability of the degradable implants has reached the qualities of conventional materials, new devices may find usage in younger and more demanding patients. Residual conventional osteosynthetic material or the necessity to remove metal increasingly seems to be more of an adverse event than daily practice in forefoot surgery. Nevertheless, some drawbacks need to be discussed. Recent literature screened for the use of bioabsorbable and biodegradable materials in forefoot surgery, available implants and indications in forefoot surgery were analysed and summarized. Apart from common indications in forefoot surgery, points of interest were the type of biomaterial, the process of biodegradation and biointegration, and possible adverse events. Materials were comprehensively discussed for each indication based on the available literature. Polylactide, polyglycoside and polydioxanone are considered safe and sufficiently stable for use in forefoot surgery. Low complication rates (e.g. 0.7% for pin fixation in hallux deformities) are given. Magnesium implants suffered from an extensive corrosive process in the first generation but now seem to be safe in forefoot surgery and offer good options compared with conventional titanium screws, especially in procedures of the first ray. Allograft bone has proven feasibility in small case series, but still lacks larger or randomized clinical trials. The first results are promising. Bioresorbable and osseointegrating devices offer attractive new possibilities for surgeons and patients. Despite all the known advantages, the difficulties and possible complications must not be forgotten, such as soft tissue reactions, unwanted osteolysis and a lower primary mechanical load capacity. Cite this article: EFORT Open Rev 2021;6:1132-1139. DOI: 10.1302/2058-5241.6.200157


2021 ◽  
Vol 22 (22) ◽  
pp. 12567
Author(s):  
Ole Jung ◽  
Bernhard Hesse ◽  
Sanja Stojanovic ◽  
Christian Seim ◽  
Timm Weitkamp ◽  
...  

Background: Magnesium (Mg) is one of the most promising materials for human use in surgery due to material characteristics such as its elastic modulus as well as its resorbable and regenerative properties. In this study, HF-coated and uncoated novel bioresorbable magnesium fixation screws for maxillofacial and dental surgical applications were investigated in vitro and in vivo to evaluate the biocompatibility of the HF coating. Methods: Mg alloy screws that had either undergone a surface treatment with hydrofluoric-acid (HF) or left untreated were investigated. In vitro investigation included XTT, BrdU and LDH in accordance with the DIN ISO 10993-5/-12. In vivo, the screws were implanted into the tibia of rabbits. After 3 and 6 weeks, degradation, local tissue reactions and bony integration were analyzed histopathologically and histomorphometrically. Additionally, SEM/EDX analysis and synchrotron phase-contrast microtomography (µCT) measurements were conducted. The in vitro analyses revealed that the Mg screws are cytocompatible, with improved results when the surface had been passivated with HF. In vivo, the HF-treated Mg screws implanted showed a reduction in gas formation, slower biodegradation and a better bony integration in comparison to the untreated Mg screws. Histopathologically, the HF-passivated screws induced a layer of macrophages as part of its biodegradation process, whereas the untreated screws caused a slight fibrous tissue reaction. SEM/EDX analysis showed that both screws formed a similar layer of calcium phosphates on their surfaces and were surrounded by bone. Furthermore, the µCT revealed the presence of a metallic core of the screws, a faster absorbing corrosion front and a slow absorbing region of corroded magnesium. Conclusions: Overall, the HF-passivated Mg fixation screws showed significantly better biocompatibility in vitro and in vivo compared to the untreated screws.


2021 ◽  
Vol 18 (6) ◽  
pp. 066018
Author(s):  
Jae-Won Jang ◽  
Yoo Na Kang ◽  
Hee Won Seo ◽  
Boil Kim ◽  
Han Kyoung Choe ◽  
...  

Abstract Objective. Neural interfaces are an essential tool to enable the human body to directly communicate with machines such as computers or prosthetic robotic arms. Since invasive electrodes can be located closer to target neurons, they have advantages such as precision in stimulation and high signal-to-noise ratio (SNR) in recording, while they often exhibit unstable performance in long-term in-vivo implantation because of the tissue damage caused by the electrodes insertion. In the present study, we investigated the electrical functionality of flexible penetrating microelectrode arrays (FPMAs) up to 3 months in in-vivo conditions. Approach. The in-vivo experiment was performed by implanting FPMAs in five rats. The in-vivo impedance as well as the action potential (AP) amplitude and SNR were analyzed over weeks. Additionally, APs were tracked over time to investigate the possibility of single neuron recording. Main results. It was observed that the FPMAs exhibited dramatic increases in impedance for the first 4 weeks after implantation, accompanied by decreases in AP amplitude. However, the increase/decrease in AP amplitude was always accompanied by the increase/decrease in background noise, resulting in quite consistently maintained SNRs. After 4 weeks of implantation, we observed two distinctive issues regarding long-term implantation, each caused by chronic tissue responses or by the delamination of insulation layer. The results demonstrate that the FPMAs successfully recorded neuronal signals up to 12 weeks, with very stably maintained SNRs, reduced by only 16.1% on average compared to the first recordings, although biological tissue reactions or physical degradation of the FPMA were present. Significance. The fabricated FPMAs successfully recorded intracortical signals for 3 months. The SNR was maintained up to 3 months and the chronic function of FPMA was comparable with other silicon based implantable electrodes.


Author(s):  
Antje Kilias ◽  
Yu-Tao Lee ◽  
Ulrich P Froriep ◽  
Charlotte Sielaff ◽  
Dominik Moser ◽  
...  

Abstract Objective. Recording and stimulating neuronal activity across different brain regions requires interfacing at multiple sites using dedicated tools while tissue reactions at the recording sites often prevent their successful long-term application. This implies the technological challenge of developing complex probe geometries while keeping the overall footprint minimal, and of selecting materials compatible with neural tissue. While the potential of soft materials in reducing tissue response is uncontested, the implantation of these materials is often limited to reliably target neuronal structures across large brain volumes. Approach. We report on the development of a new multi-electrode array exploiting the advantages of soft and stiff materials by combining 7-µm-thin polyimide wings carrying platinum electrodes with a silicon backbone enabling a safe probe implantation. The probe fabrication applies microsystems technologies in combination with a temporal wafer fixation method for rear side processing, i.e. grinding and deep reactive ion etching, of slender probe shanks and electrode wings. The wing-type neural probes are chronically implanted into the entorhinal-hippocampal formation in the mouse for in vivo recordings of freely behaving animals. Main results. Probes comprising the novel wing-type electrodes have been realized and characterized in view of their electrical performance and insertion capability. Chronic electrophysiological in vivo recordings of the entorhinal-hippocampal network in the mouse of up to 104 days demonstrated a stable yield of channels containing identifiable multi-unit and single-unit activity outperforming probes with electrodes residing on a Si backbone. Significance. The innovative fabrication process using a process compatible, temporary wafer bonding allowed to realize new Michigan style probe arrays. The wing-type probe design enables a µm-precise probe insertion into brain tissue and long-term stable recordings of unit activity due to the application of a stable backbone and 7-µm-thin probe wings provoking locally a minimal tissue response and protruding from the glial scare of the backbone.


Sign in / Sign up

Export Citation Format

Share Document